Literature DB >> 17996389

Time dependence of intrafraction patient motion assessed by repeat stereoscopic imaging.

Mischa S Hoogeman1, Joost J Nuyttens, Peter C Levendag, Ben J M Heijmen.   

Abstract

PURPOSE: To quantify intrafraction patient motion and its time dependence in immobilized intracranial and extracranial patients. The data can be used to optimize the intrafraction imaging frequency and consequent patient setup correction with an image guidance and tracking system, and to establish the required safety margins in the absence of such a system. METHOD AND MATERIALS: The intrafraction motion of 32 intracranial patients, immobilized with a thermoplastic mask, and 11 supine- and 14 prone-treated extracranial spine patients, immobilized with a vacuum bag, were analyzed. The motion was recorded by an X-ray, stereoscopic, image-guidance system. For each group, we calculated separately the systematic (overall mean and SD) and the random displacement as a function of elapsed intrafraction time.
RESULTS: The SD of the systematic intrafraction displacements increased linearly over time for all three patient groups. For intracranial-, supine-, and prone-treated patients, the SD increased to 0.8, 1.2, and 2.2 mm, respectively, in a period of 15 min. The random displacements for the prone-treated patients were significantly higher than for the other groups, namely 1.6 mm (1 SD), probably caused by respiratory motion.
CONCLUSIONS: Despite the applied immobilization devices, patients drift away from their initial position during a treatment fraction. These drifts are in general small if compared with conventional treatment margins, but will significantly contribute to the margin for high-precision radiation treatments with treatment times of 15 min or longer.

Entities:  

Mesh:

Year:  2007        PMID: 17996389     DOI: 10.1016/j.ijrobp.2007.08.066

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  74 in total

Review 1.  Volumetric modulated arc therapy: a review of current literature and clinical use in practice.

Authors:  M Teoh; C H Clark; K Wood; S Whitaker; A Nisbet
Journal:  Br J Radiol       Date:  2011-11       Impact factor: 3.039

2.  A dosimetric comparison between CyberKnife and tomotherapy treatment plans for single brain metastasis.

Authors:  Daniela Greto; Stefania Pallotta; Laura Masi; Cinzia Talamonti; Livia Marrazzo; Raffaella Doro; Calogero Saieva; Silvia Scoccianti; Isacco Desideri; Lorenzo Livi
Journal:  Radiol Med       Date:  2017-02-15       Impact factor: 3.469

3.  New possibilities for volumetric-modulated arc therapy using the Agility™ 160-leaf multileaf collimator.

Authors:  Nadine Blümer; Christian Scherf; Janett Köhn; Eugen Kara; Britta Loutfi-Krauß; Detlef Imhoff; Claus Rödel; Ulla Ramm; Jörg Licher
Journal:  Strahlenther Onkol       Date:  2014-07-25       Impact factor: 3.621

4.  Robotic real-time translational and rotational head motion correction during frameless stereotactic radiosurgery.

Authors:  Xinmin Liu; Andrew H Belcher; Zachary Grelewicz; Rodney D Wiersma
Journal:  Med Phys       Date:  2015-06       Impact factor: 4.071

5.  A novel approach to SBRT patient quality assurance using EPID-based real-time transit dosimetry : A step to QA with in vivo EPID dosimetry.

Authors:  Christos Moustakis; Fatemeh Ebrahimi Tazehmahalleh; Khaled Elsayad; Francis Fezeu; Sergiu Scobioala
Journal:  Strahlenther Onkol       Date:  2020-01-10       Impact factor: 3.621

6.  Accuracy of positional correction for the floor-mounted kV X-ray IGRT system in angled couch positions.

Authors:  Satoshi Koubuchi; Toru Takakura; Mitsuhiro Nakamura; Takashi Mizowaki; Manabu Nakata; Masahiro Hiraoka
Journal:  Radiol Phys Technol       Date:  2014-06-13

7.  Initial evaluation of intrafraction motion using frameless CyberKnife VSI system.

Authors:  Alejandro Floriano; Icíar Santa-Olalla; Alberto Sanchez-Reyes
Journal:  Rep Pract Oncol Radiother       Date:  2013-04-16

8.  Is helical tomotherapy accurate and safe enough for spine stereotactic body radiotherapy?

Authors:  Yoonsun Chung; Hong In Yoon; Joo Ho Kim; Ki Chang Nam; Woong Sub Koom
Journal:  J Cancer Res Clin Oncol       Date:  2012-10-02       Impact factor: 4.553

9.  Shorter treatment times reduce the impact of intra-fractional motion : A real-time 4DUS study comparing VMAT vs. step-and-shoot IMRT for prostate cancer.

Authors:  Hendrik Ballhausen; Minglun Li; Ute Ganswindt; Claus Belka
Journal:  Strahlenther Onkol       Date:  2018-03-09       Impact factor: 3.621

10.  Semi-robotic 6 degree of freedom positioning for intracranial high precision radiotherapy; first phantom and clinical results.

Authors:  Jürgen Wilbert; Matthias Guckenberger; Bülent Polat; Otto Sauer; Michael Vogele; Michael Flentje; Reinhart A Sweeney
Journal:  Radiat Oncol       Date:  2010-05-26       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.