Literature DB >> 33289796

Effect of the presence of orthodontic brackets on intraoral scans.

Sung-Ja Kang, Youn-Ju Kee, Kyungmin Clara Lee.   

Abstract

OBJECTIVES: The need for intraoral scanning in the presence of brackets has increased for monitoring tooth movement during orthodontic treatment. The purpose of this study was to evaluate the effect of orthodontic brackets bonded to tooth surfaces on intraoral scans.
MATERIALS AND METHODS: Intraoral scans were performed in 30 patients using both iTero and Trios scanners before and after bonding of the brackets. The two sets of intraoral scans of each patient and intraoral scans with and without brackets were superimposed using a best-fit algorithm, and three-dimensional (3D) surface analysis was performed. In each superimposition, discrepancies in the 3D axes and arch-width measurements in the incisor and molar regions were compared. In addition, the range of distortion around the brackets was evaluated on the cross sections of each superimposition.
RESULTS: The overall discrepancies between the intraoral scans with and without brackets were within 0.30 mm. The arch-width discrepancies in the molar region were greater than those in the incisor region, but the differences were not statistically significant (P = .972 for iTero; P = .960 for Trios). The cross sections of the superimposed intraoral scans with and without brackets showed that the deviations were within 0.40 mm in the horizontal section and within 0.35 mm in the vertical section around the brackets.
CONCLUSIONS: The results of this study indicate that the accuracy of intraoral scans, even in the presence of brackets, is clinically acceptable, and the regions beyond 0.50 mm around the brackets should be used for superimposition on images without brackets.
© 2021 by The EH Angle Education and Research Foundation, Inc.

Entities:  

Keywords:  Accuracy; Image noise; Intraoral scan; Orthodontic brackets

Mesh:

Year:  2021        PMID: 33289796      PMCID: PMC8032282          DOI: 10.2319/040420-254.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  21 in total

Review 1.  Craniofacial imaging in orthodontics: historical perspective, current status, and future developments.

Authors:  J C Quintero; A Trosien; D Hatcher; S Kapila
Journal:  Angle Orthod       Date:  1999-12       Impact factor: 2.079

2.  Complete 3-D reconstruction of dental cast shape using perceptual grouping.

Authors:  Y Hirogaki; T Sohmura; H Satoh; J Takahashi; K Takada
Journal:  IEEE Trans Med Imaging       Date:  2001-10       Impact factor: 10.048

3.  Current status and future needs in craniofacial imaging.

Authors:  J Mah; D Hatcher
Journal:  Orthod Craniofac Res       Date:  2003       Impact factor: 1.826

4.  Radiographic technique and brackets affect measurements of proximal enamel thickness on mandibular incisors.

Authors:  Amy Giok Phing Ang; Pauline Antoinette Josephine Steegmans; Wouter Kerdijk; Christos Livas; Yijin Ren
Journal:  Eur J Orthod       Date:  2016-01-28       Impact factor: 3.075

5.  Manual and computer-aided space analysis: a comparative study.

Authors:  U R Schirmer; W A Wiltshire
Journal:  Am J Orthod Dentofacial Orthop       Date:  1997-12       Impact factor: 2.650

Review 6.  Accuracy, reliability, and efficiency of intraoral scanners for full-arch impressions: a systematic review of the clinical evidence.

Authors:  Cecilia Goracci; Lorenzo Franchi; Alessandro Vichi; Marco Ferrari
Journal:  Eur J Orthod       Date:  2015-10-20       Impact factor: 3.075

Review 7.  Digital versus conventional impressions for fixed prosthodontics: A systematic review and meta-analysis.

Authors:  Konstantinos M Chochlidakis; Panos Papaspyridakos; Alessandro Geminiani; Chun-Jung Chen; I Jung Feng; Carlo Ercoli
Journal:  J Prosthet Dent       Date:  2016-03-02       Impact factor: 3.426

8.  The development of an index of orthodontic treatment priority.

Authors:  P H Brook; W C Shaw
Journal:  Eur J Orthod       Date:  1989-08       Impact factor: 3.075

9.  Assessment of metal artifacts in three-dimensional dental surface models derived by cone-beam computed tomography.

Authors:  Wael Nabha; Young-Min Hong; Jin-Hyoung Cho; Hyeon-Shik Hwang
Journal:  Korean J Orthod       Date:  2014-09-25       Impact factor: 1.372

10.  Accuracy on Scanned Images of Full Arch Models with Orthodontic Brackets by Various Intraoral Scanners in the Presence of Artificial Saliva.

Authors:  Jihu Song; Minji Kim
Journal:  Biomed Res Int       Date:  2020-02-27       Impact factor: 3.411

View more
  4 in total

1.  The transfer accuracy of digital and conventional full-arch impressions influenced by fixed orthodontic appliances: a reference aid-based in vitro study.

Authors:  Maximiliane Amelie Schlenz; Katharina Klaus; Alexander Schmidt; Bernd Wöstmann; Marco Mersmann; Sabine Ruf; Niko Christian Bock
Journal:  Clin Oral Investig       Date:  2022-09-15       Impact factor: 3.606

2.  Transfer accuracy of 3D-printed trays for indirect bonding of orthodontic brackets.

Authors:  Petra C Bachour; Robert Klabunde; Thorsten Grünheid
Journal:  Angle Orthod       Date:  2022-05-01       Impact factor: 2.684

3.  Accuracy of a Method to Monitor Root Position Using a 3D Digital Crown/Root Model during Orthodontic Treatments.

Authors:  Kaho Ogawa; Yoshiki Ishida; Yukinori Kuwajima; Cliff Lee; Jacob R Emge; Mitsuru Izumisawa; Kazuro Satoh; Shigemi Ishikawa-Nagai; John D Da Silva; Chia-Yu Chen
Journal:  Tomography       Date:  2022-02-23

4.  The Effects of Orthodontic Brackets on the Time and Accuracy of Digital Impression Taking.

Authors:  Hyojin Heo; Minji Kim
Journal:  Int J Environ Res Public Health       Date:  2021-05-16       Impact factor: 3.390

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.