Literature DB >> 33275168

Experimental evaluation of precision and accuracy of RSA in the lumbar spine.

Marie Christina Keller1, Christof Hurschler1, Michael Schwarze2.   

Abstract

PURPOSE: Roentgen stereophotogrammetric analysis is a technique to make accurate assessments of the relative position and orientation of bone structures and implants in vivo. While the precision and accuracy of stereophotogrammetry for hip and knee arthroplasty is well documented, there is insufficient knowledge of the technique's precision and, especially accuracy when applied to rotational movements in the spinal region.
METHODS: The motion of one cadaver lumbar spine segment (L3/L4) was analyzed in flexion-extension, lateral bending and internal rotation. The specific aim of this study was to examine the precision and accuracy of stereophotogrammetry in a controlled in vitro setting, taking the surrounding soft tissue into account. The second objective of this study was to investigate the effect of different focal spot values of X-ray tubes.
RESULTS: Overall, the precision of flexion-extension measurements was found to be better when using a 0.6 mm focal spot value rather than 1.2 mm (± 0.056° and ± 0.153°; respectively), and accuracy was also slightly better for the 0.6 mm focal spot value compared to 1.2 mm (- 0.137° and - 0.170°; respectively). The best values for precision and accuracy were obtained in lateral bending for both 0.6 mm and 1.2 mm focal spot values (precision: ± 0.019° and ± 0.015°, respectively; accuracy: - 0.041° and - 0.035°).
CONCLUSION: In summary, the results suggest stereophotogrammetry to be a highly precise method to analyze motion of the lumbar spine. Since precision and accuracy are better than 0.2° for both focal spot values, the choice between these is of minor clinical relevance.
© 2020. The Author(s).

Entities:  

Keywords:  In-vitro; Lumbar spine; RSA; Validation

Year:  2020        PMID: 33275168     DOI: 10.1007/s00586-020-06672-5

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  18 in total

1.  The effect of standard lumbar discectomy on segmental motion: 5-year follow-up using radiostereometry.

Authors:  K Halldin; B Zoëga; P Nyberg; J Kärrholm; B I Lind
Journal:  Int Orthop       Date:  2005-03-01       Impact factor: 3.075

2.  Comparing precision of distortion-compensated and stereophotogrammetric Roentgen analysis when monitoring fusion in the cervical spine.

Authors:  Gunnar Leivseth; Frode Kolstad; Oystein P Nygaard; Björn Zoega; W Frobin; P Brinckmann
Journal:  Eur Spine J       Date:  2005-09-15       Impact factor: 3.134

3.  Disc replacement using Pro-Disc C versus fusion: a prospective randomised and controlled radiographic and clinical study.

Authors:  A Nabhan; F Ahlhelm; T Pitzen; W I Steudel; J Jung; K Shariat; O Steimer; F Bachelier; D Pape
Journal:  Eur Spine J       Date:  2006-11-14       Impact factor: 3.134

4.  Experimental analysis of Model-Based Roentgen Stereophotogrammetric Analysis (MBRSA) on four typical prosthesis components.

Authors:  Frank Seehaus; Judith Emmerich; Bart L Kaptein; Henning Windhagen; Christof Hurschler
Journal:  J Biomech Eng       Date:  2009-04       Impact factor: 2.097

5.  Three-dimensional bone-implant movements in trochanteric hip fractures: Precision and accuracy of radiostereometric analysis in a phantom model.

Authors:  Alicja J Bojan; Charles Bragdon; Anders Jönsson; Carl Ekholm; Johan Kärrholm
Journal:  J Orthop Res       Date:  2015-02-24       Impact factor: 3.494

6.  Kinematic analysis of spinal fusions.

Authors:  T H Olsson; G Selvik; S Willner
Journal:  Invest Radiol       Date:  1976 May-Jun       Impact factor: 6.016

7.  A method to evaluate the in vivo behaviour of lumbar spine implants.

Authors:  G Gunnarsson; P Axelsson; R Johnsson; B Strömqvist
Journal:  Eur Spine J       Date:  2000-06       Impact factor: 3.134

8.  Guidelines for standardization of radiostereometry (RSA) of implants.

Authors:  Edward R Valstar; Richie Gill; Leif Ryd; Gunnar Flivik; Niclas Börlin; Johan Kärrholm
Journal:  Acta Orthop       Date:  2005-08       Impact factor: 3.717

9.  The accuracy and precision of radiostereometric analysis in monitoring tibial plateau fractures.

Authors:  Lucian B Solomon; Aaron W Stevenson; Stuart A Callary; Thomas R Sullivan; Donald W Howie; Mellick J Chehade
Journal:  Acta Orthop       Date:  2010-08       Impact factor: 3.717

10.  Plate fixation adds stability to two-level anterior fusion in the cervical spine: a randomized study using radiostereometry.

Authors:  B Zoëga; J Kärrholm; B Lind
Journal:  Eur Spine J       Date:  1998       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.