Literature DB >> 25640537

Three-dimensional bone-implant movements in trochanteric hip fractures: Precision and accuracy of radiostereometric analysis in a phantom model.

Alicja J Bojan1, Charles Bragdon, Anders Jönsson, Carl Ekholm, Johan Kärrholm.   

Abstract

The accuracy and precision of RSA were evaluated in the experimental study of screw cut-out complication after fixation of trochanteric fractures. A plastic bone model of a two-part trochanteric fracture was constructed with a Gamma nail implant incorporating RSA markers. The femoral head fragment was attached to a separate rotational table and the femoral shaft was mounted on the micrometer. Three main motions were simulated: Femoral head translation and rotation along the axis of the lag screw and fracture fragment translation along anatomical axes. Accuracy and precision were determined according to ISO 16,087 and ASTM standard F2385-04. Translations along the lag screw axis were measured with a precision within  ±0.14 mm and an accuracy within ±0.03 mm. With simultaneous translations along all three anatomical axes, lowest precision was measured for the x-axis (±0.29, 0.07 mm, respectively), but improved when analyzed as a vector (±0.08, 0.03 mm). The precision and accuracy of femoral head rotations were within 0.5° and 0.18°, respectively. The resolution of the RSA method tested in this model was high, though it varied depending on the type of analyzed motion. This information is valuable when selecting and interpreting outcome parameters evaluating implant migration and osteosynthesis stability in future clinical RSA studies.
© 2014 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Keywords:  cut-out; intramedullary nailing; radiostereometry; trochanteric hip fractures

Mesh:

Year:  2015        PMID: 25640537     DOI: 10.1002/jor.22822

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  6 in total

1.  Experimental evaluation of precision and accuracy of RSA in the lumbar spine.

Authors:  Marie Christina Keller; Christof Hurschler; Michael Schwarze
Journal:  Eur Spine J       Date:  2020-12-04       Impact factor: 3.134

2.  Reconstructing the anterolateral ligament does not decrease rotational knee laxity in ACL-reconstructed knees.

Authors:  Kasper Stentz-Olesen; Emil Toft Nielsen; Sepp de Raedt; Peter Bo Jørgensen; Ole Gade Sørensen; Bart Kaptein; Kjeld Søballe; Maiken Stilling
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-03-17       Impact factor: 4.342

3.  Validation of static and dynamic radiostereometric analysis of the knee joint using bone models from CT data.

Authors:  K Stentz-Olesen; E T Nielsen; S De Raedt; P B Jørgensen; O G Sørensen; B L Kaptein; M S Andersen; M Stilling
Journal:  Bone Joint Res       Date:  2017-06       Impact factor: 5.853

4.  Development of a morphology-based modeling technique for tracking solid-body displacements: examining the reliability of a potential MRI-only approach for joint kinematics assessment.

Authors:  Niladri K Mahato; Stephane Montuelle; John Cotton; Susan Williams; James Thomas; Brian Clark
Journal:  BMC Med Imaging       Date:  2016-05-18       Impact factor: 1.930

5.  Marker free model-based radiostereometric analysis for evaluation of hip joint kinematics: A validation study.

Authors:  L Hansen; S De Raedt; P B Jørgensen; B Mygind-Klavsen; B Kaptein; M Stilling
Journal:  Bone Joint Res       Date:  2018-07-07       Impact factor: 5.853

6.  Radiostereometric analysis of the initial stability of internally fixed femoral neck fractures under differential loading.

Authors:  Sami Finnilä; Niko Moritz; Niko Strandberg; Jessica J Alm; Hannu T Aro
Journal:  J Orthop Res       Date:  2018-10-25       Impact factor: 3.494

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.