Literature DB >> 3325290

A new approach to image subtraction in immunoscintigraphy: preliminary results.

J C Liehn1, P Hannequin, S Nasca, D Lebrun, A Cattan, J Valeyre.   

Abstract

Recently proposed image comparison software is applied to immunoscintigraphy. The software performs geometric and gray level registration of two images and generates an image of the statistically significant differences. It permits the comparison of scintigraphic images recorded at different times. It is used to subtract 113mIn and 111Inphytate colloid liver scans and early (blood pool) images from 131I or 111In-monoclonal Ab images and to compare Ab images recorded at different times. Using the procedures made possible by this software, only images recorded using the same radionuclide or using radionuclides of about the same energy are compared. Anti CEA, 19-9 and OC 125 F(ab)2 fragments labeled with 131I or 111In are used in 32 patients with 47 demonstrated recurrences or metastases of colorectal or ovarian cancers. The overall sensitivities of the unprocessed and processed images are 25/47 and 41/47 respectively. The improvement in sensitivity is particularly high in the liver when In labelled Ab are used. This technique improves the contrast of the images, but the interpretation must take into account the components of the non target activity (kidney, bone marrow, colon...) which are not removed by the image subtraction method.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3325290     DOI: 10.1007/bf00292489

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  10 in total

1.  Automated comparison of scintigraphic images.

Authors:  A Venot; J C Liehn; J F Lebruchec; J C Roucayrol
Journal:  J Nucl Med       Date:  1986-08       Impact factor: 10.057

2.  Dynamic variable background subtraction: a simple means of displaying radiolabeled monoclonal antibody scintigrams.

Authors:  R L Wahl; M C Tuscan; J M Botti
Journal:  J Nucl Med       Date:  1986-04       Impact factor: 10.057

3.  Ovarian cancer: diagnosis using 123I monoclonal antibody in comparison with surgical findings.

Authors:  M Granowska; J Shepherd; K E Britton; B Ward; S Mather; J Taylor-Papadimitriou; A A Epenetos; M J Carroll; C C Nimmon; L A Hawkins
Journal:  Nucl Med Commun       Date:  1984-08       Impact factor: 1.690

4.  An automated method for the normalization of scintigraphic images.

Authors:  A Venot; J F Lebruchec; J L Golmard; J C Roucayrol
Journal:  J Nucl Med       Date:  1983-06       Impact factor: 10.057

5.  Physical approach for the reduction of dual radionuclide image subtraction artefacts in immunoscintigraphy.

Authors:  A C Perkins; D R Whalley; J G Hardy
Journal:  Nucl Med Commun       Date:  1984-08       Impact factor: 1.690

6.  Differences in tumour and normal tissue concentrations of iodine- and indium-labelled monoclonal antibody. I. The effect on image contrast in clinical studies.

Authors:  A C Perkins; M V Pimm
Journal:  Eur J Nucl Med       Date:  1985

7.  Analysis of radioimmunodetection of tumors by the subtraction technique.

Authors:  A J Green; R H Begent; P A Keep; K D Bagshawe
Journal:  J Nucl Med       Date:  1984-01       Impact factor: 10.057

8.  The limitations of the dual radionuclide subtraction technique for the external detection of tumours by radioiodine-labelled antibodies.

Authors:  R J Ott; L J Grey; M A Zivanovic; M A Flower; N G Trott; V Moshakis; R C Coombes; A M Neville; M G Ormerod; J H Westwood; V R McCready
Journal:  Br J Radiol       Date:  1983-02       Impact factor: 3.039

9.  Preliminary findings in the evaluation of hepatic malignancies by radioimmunodetection, X-ray computed tomography, and magnetic resonance imaging.

Authors:  F H DeLand; A Lieber; M D Ram; D M Goldenberg
Journal:  Eur J Nucl Med       Date:  1986

10.  Imaging approach in radioimmunodetection.

Authors:  F H DeLand; E E Kim; G Simmons; D M Goldenberg
Journal:  Cancer Res       Date:  1980-08       Impact factor: 12.701

  10 in total
  3 in total

1.  Histological correlation of 17 prospective immunoscintigraphies of recurrences of colorectal carcinomas using indium-111-labeled anti-cea and(or) 19-9 monoclonal antibodies.

Authors:  A Chetanneau; P A Lehur; D Ripoche; P Peltier; J C Saccavini; J P Vuillez; N Tournemaine; P Thedrez; J F Chatal
Journal:  Eur J Nucl Med       Date:  1989

2.  Improvement of parathyroid Tl-Tc scintigraphy by using a new image subtraction method.

Authors:  J C Liehn; S Amico; M J Delisle; J B Flament
Journal:  Eur J Nucl Med       Date:  1988

3.  Visualization of myocardial infarction six hours after injection of 111 In-antimyosin antibodies using an image subtraction technique.

Authors:  J Ouzan; D Wilson; C Pèrualt; D Metz; F Torossian; C Gibold; A Loboguerrero; E Carre; J C Liehn; J Elaerts
Journal:  Int J Card Imaging       Date:  1994-09
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.