Literature DB >> 2844539

Improvement of parathyroid Tl-Tc scintigraphy by using a new image subtraction method.

J C Liehn1, S Amico, M J Delisle, J B Flament.   

Abstract

Forty five thallium-technetium parathyroid scans were performed preoperatively in patients with a high suspicion of parathyroid adenoma or hyperplasia. The patients were imaged after sequential IV injection of 201Tl-thallous chloride (74 MBq) and 99mTc-pertechnetate (222 MBq) using a gamma camera with a pinhole collimator. According to surgical findings, the prevalence of parathyroid abnormalities was 42/45: single (34 patients) and double (1 patient) adenomas, hyperplasia (7 patients, 16 hyperplastic glands). Three methods of analysis of scintigraphic images were compared. Method one was the visual comparison of the thallium and the technetium images. Method two used the subtraction image obtained after normalisation. Method three used a new image comparison method which performs the geometric and gray level registrations of the two images and generates the image of the significant differences. Three observers were involved in the evaluation procedures. Surgery and histological examinations were taken as the gold standard. Results show that the sensitivity is increased by applying method three. The interobserver reproducibility of the results is also higher for method three. We conclude that an adequate image subtraction technique significantly increases the diagnostic value of parathyroid scintigraphy.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 2844539     DOI: 10.1007/bf00257325

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  20 in total

1.  Automated comparison of scintigraphic images.

Authors:  A Venot; J C Liehn; J F Lebruchec; J C Roucayrol
Journal:  J Nucl Med       Date:  1986-08       Impact factor: 10.057

2.  Preliminary results of thallium 201 and technetium 99m subtraction scanning of parathyroid glands.

Authors:  M H Wheeler; B J Harrison; A P French; K G Leach
Journal:  Surgery       Date:  1984-12       Impact factor: 3.982

3.  An automated method for the normalization of scintigraphic images.

Authors:  A Venot; J F Lebruchec; J L Golmard; J C Roucayrol
Journal:  J Nucl Med       Date:  1983-06       Impact factor: 10.057

4.  Scintigraphic detection of adenoma in primary hyperparathyroidism.

Authors:  E K Pauwels; J H Bolk; J M Heslinga
Journal:  Eur J Nucl Med       Date:  1985

5.  Dual isotope subtraction parathyroid scintigraphy in the preoperative evaluation of suspected hyperparathyroidism.

Authors:  R M Basarab; A Manni; T S Harrison
Journal:  Clin Nucl Med       Date:  1985-04       Impact factor: 7.794

6.  Parathyroid adenomas evaluated by Tl-201/Tc-99m pertechnetate subtraction scintigraphy and high-resolution ultrasonography.

Authors:  G G Winzelberg; J D Hydovitz; K R O'Hara; K M Anderson; E Turbiner; T S Danowski; R D Lippe; G A Melada; A M Harrison
Journal:  Radiology       Date:  1985-04       Impact factor: 11.105

7.  Localization of enlarged parathyroid glands by thallium-201 and technetium-99m subtraction imaging. Gland mass and parathormone levels in primary hyperparathyroidism.

Authors:  T M Gimlette; W H Taylor
Journal:  Clin Nucl Med       Date:  1985-04       Impact factor: 7.794

8.  Thallium-pertechnetate subtraction scintigraphy: a quantitative comparison between adenomatous and hyperplastic parathyroid glands.

Authors:  G M Blake; R C Percival; J A Kanis
Journal:  Eur J Nucl Med       Date:  1986

9.  Limits to parathyroid imaging with thallium-201 confirmed by tissue uptake and phantom studies.

Authors:  T M Gimlette; S M Brownless; W H Taylor; R Shields; E P Simkin
Journal:  J Nucl Med       Date:  1986-08       Impact factor: 10.057

10.  Thallium-technetium parathyroid scan. A useful noninvasive technique for localization of abnormal parathyroid tissue.

Authors:  A Manni; R M Basarab; P V Plourde; D Koivunen; T S Harrison; R J Santen
Journal:  Arch Intern Med       Date:  1986-06
View more
  1 in total

1.  Visualization of myocardial infarction six hours after injection of 111 In-antimyosin antibodies using an image subtraction technique.

Authors:  J Ouzan; D Wilson; C Pèrualt; D Metz; F Torossian; C Gibold; A Loboguerrero; E Carre; J C Liehn; J Elaerts
Journal:  Int J Card Imaging       Date:  1994-09
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.