Literature DB >> 3016216

Automated comparison of scintigraphic images.

A Venot, J C Liehn, J F Lebruchec, J C Roucayrol.   

Abstract

New algorithms for automated comparison of scintigraphic images have been developed and are described here. The first step presented here is the registration of the images, performed by optimizing, with respect to the registration parameters (two translational shifts, one angle of rotation, the two parameters of a linear transformation of the gray levels), the stochastic sign change (SSC) criterion. The optimization of this criterion is demonstrated to be efficiently performed using the adaptative random search strategy; a more limited but less time-consuming method is also presented. The second step described is the point-by-point comparison of the registered images. The pixel-by-pixel application of Poisson variable statistical tests permits the generation of the significant image differences. From such images it is possible to detect modifications which escape visual inspection. Examples of applications are given in controlled and routine conditions. These algorithms are useful for the processing of many investigations and are proposed for implementation on all nuclear medicine data processing systems.

Mesh:

Substances:

Year:  1986        PMID: 3016216

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  5 in total

Review 1.  Measurement of myocardial blood flow by UFCT: towards clinical applicability.

Authors:  C J Wolfkiel; B H Brundage
Journal:  Int J Card Imaging       Date:  1991

2.  A new approach to image subtraction in immunoscintigraphy: preliminary results.

Authors:  J C Liehn; P Hannequin; S Nasca; D Lebrun; A Cattan; J Valeyre
Journal:  Eur J Nucl Med       Date:  1987

3.  Improvement of parathyroid Tl-Tc scintigraphy by using a new image subtraction method.

Authors:  J C Liehn; S Amico; M J Delisle; J B Flament
Journal:  Eur J Nucl Med       Date:  1988

4.  Scintigraphic study of gallbladder emptying and duodenogastric reflux during non-ulcerous dyspepsia.

Authors:  J P Caravel; B Bonaz; J Hostein; R Bost; J Fournet
Journal:  Eur J Nucl Med       Date:  1990

5.  Visualization of myocardial infarction six hours after injection of 111 In-antimyosin antibodies using an image subtraction technique.

Authors:  J Ouzan; D Wilson; C Pèrualt; D Metz; F Torossian; C Gibold; A Loboguerrero; E Carre; J C Liehn; J Elaerts
Journal:  Int J Card Imaging       Date:  1994-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.