Evaluation of commercial serodiagnostic kits for toxoplasmosis.

M Wilson1, D A Ware, K W Walls.   

Abstract

To evaluate commercially available diagnostic kits for human immunoglobulin G to Toxoplasma gondii, we purchased three enzyme immunoassay (EIA) (Cordia-T, Toxo Bio-EnzaBead, and Toxoelisa), two indirect hemagglutination (IHA) (TPM-Test and ToxHAtest), one fluoroimmunoassay (Toxoplasma-G FIAX), and one latex agglutination (Eiken Toxotest-MT) kit from U.S. suppliers. A total of 100 serum specimens, including 27 that were negative (less than 1:16) and 73 that were positive for the various titers in the Toxoplasma indirect immunofluorescence (IIF) test, were tested once with each kit; serum samples with discrepant results were retested. Qualitatively, results obtained with the Toxo Bio-EnzaBead EIA, the TMP-Test IHA, and FIAX, and the Toxotest-MT latex agglutination kits agreed exactly with those of IIF. Although all IIF-positive serum samples were detected by the Cordia-T and the Toxoelisa EIAs, four samples determined to be negative by IIF were identified as positive with the Cordia-T kit, and six negative samples by IIF were determined to be positive with the Toxoelisa kit. Results of the ToxoHAtest IHA kit were extremely difficult to read. Quantitatively, the seven kits were difficult to compare because the expression of results was not standardized. Of the four kits that gave positive results in titers, Toxoplasma-G FIAX had the closest agreement with IIF, as determined by the Spearman rank correlation coefficient (0.9168), followed by the Eiken Toxotest-MT (0.8293), the Toxo Bio-EnzaBead (0.7553), and the TPM-Test (0.7206) kits.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3323222      PMCID: PMC269466          DOI: 10.1128/jcm.25.12.2262-2265.1987

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  11 in total

1.  Detection of antibodies to Toxoplasma gondii: a comparison of three test kits.

Authors:  J Lester
Journal:  Med Lab Sci       Date:  1983-10

2.  Serologic diagnosis of toxoplasmosis with emphasis on the detection of Toxoplasma-specific immunoglobulin M antibodies.

Authors:  J C Fung; A Clogston; P Swenson; M Kaplan
Journal:  Am J Clin Pathol       Date:  1985-02       Impact factor: 2.493

3.  Evaluation of the FIAX semiautomatic fluorescent immunoassay system for the detection of IgG antibodies to Toxoplasma gondii.

Authors:  L G Carlson; J J Plorde
Journal:  Diagn Microbiol Infect Dis       Date:  1983-09       Impact factor: 2.803

4.  Evaluation of a commercial latex agglutination method for toxoplasmosis.

Authors:  K W Walls; J S Remington
Journal:  Diagn Microbiol Infect Dis       Date:  1983-12       Impact factor: 2.803

5.  Automated immunofluorescence test for toxoplasmosis.

Authors:  M A Gordon; R A Duncan; L C Kingsley
Journal:  J Clin Microbiol       Date:  1981-02       Impact factor: 5.948

6.  Standardized quantitative enzyme-linked immunoassay for antibodies to Toxoplasma gondii.

Authors:  T M Lin; S P Halbert; G R O'Connor
Journal:  J Clin Microbiol       Date:  1980-06       Impact factor: 5.948

7.  Direct agglutination test for diagnosis of Toxoplasma infection: method for increasing sensitivity and specificity.

Authors:  G Desmonts; J S Remington
Journal:  J Clin Microbiol       Date:  1980-06       Impact factor: 5.948

8.  An enzyme-linked immunosorbent assay for detection of IgM antibodies to Toxoplasma gondii: use for diagnosis of acute acquired toxoplasmosis.

Authors:  Y Naot; J S Remington
Journal:  J Infect Dis       Date:  1980-11       Impact factor: 5.226

9.  An evaluation of the ToxHA test for the detection of antibodies to Toxoplasma gondii in human serum.

Authors:  A H Balfour; J B Bridges; J P Harford
Journal:  J Clin Pathol       Date:  1980-07       Impact factor: 3.411

10.  Reverse enzyme immunoassay for detection of specific anti-Toxoplasma immunoglobulin M antibodies.

Authors:  E L Franco; K W Walls; A J Sulzer
Journal:  J Clin Microbiol       Date:  1981-05       Impact factor: 5.948

View more
  10 in total

1.  Evaluation of ELISA for the detection of Toxoplasma antibodies in swine sera.

Authors:  V Hirvelä-Koski
Journal:  Acta Vet Scand       Date:  1990       Impact factor: 1.695

2.  Comparison of the Vitek Immunodiagnostic Assay System with an indirect immunoassay (Toxostat Test Kit) for detection of immunoglobulin G antibodies to Toxoplasma gondii in clinical specimens.

Authors:  R L Sandin; C C Knapp; G S Hall; J A Washington; I Rutherford
Journal:  J Clin Microbiol       Date:  1991-12       Impact factor: 5.948

3.  [Serodiagnosis of toxoplasmosis: a comparative multicenter study of a standard scale through various actual tests and expression of the results in international units. Groupe de travail toxoplasmose du Contrôle national de qualité en parasotologie. Syndicat des fabricants de réactifs de laboratoire. Groupe de travail standardisation des tests sérologiques du Réseau européen de lutte contre la toxoplasmose congénitale].

Authors:  J C Petithory; P Ambroise-Thomas; J De Loye; H Pelloux; A Goullier-Fleuret; M Milgram; C Buffard; J P Garin
Journal:  Bull World Health Organ       Date:  1996       Impact factor: 9.408

4.  Application of quantitative immunofluorescence to clinical serology: antibody levels of Toxoplasma gondii.

Authors:  D S Kaplan; G L Picciolo
Journal:  J Clin Microbiol       Date:  1989-09       Impact factor: 5.948

5.  Evaluation of the second generation IMx Toxo IgG antibody assay for detection of antibodies to Toxoplasma gondii in human sera.

Authors:  C De Champs; H Pelloux; M Cambon; H Fricker-Hidalgo; A Goullier-Fleuret; P Ambroise-Thomas
Journal:  J Clin Lab Anal       Date:  1997       Impact factor: 2.352

6.  Diagnosis of toxoplasmosis by joint detection of immunoglobulin A and immunoglobulin M.

Authors:  M Arcavi; G Orfus; G Griemberg
Journal:  J Clin Microbiol       Date:  1997-06       Impact factor: 5.948

7.  Evaluation of six commercial kits for detection of human immunoglobulin M antibodies to Toxoplasma gondii. The FDA Toxoplasmosis Ad Hoc Working Group.

Authors:  M Wilson; J S Remington; C Clavet; G Varney; C Press; D Ware
Journal:  J Clin Microbiol       Date:  1997-12       Impact factor: 5.948

8.  The differential agglutination test as a diagnostic aid in cases of toxoplasmic lymphadenitis.

Authors:  Jose G Montoya; Andrew Berry; Fernando Rosso; Jack S Remington
Journal:  J Clin Microbiol       Date:  2007-02-21       Impact factor: 5.948

9.  [Multicenter study of toxoplasma serology using various commercial ELISA reagents. Work Group Toxoplasmosis of the National Agency for Quality Control in Parasitology].

Authors:  F Derouin; Y J Garin; C Buffard; F Berthelot; J C Petithory
Journal:  Bull World Health Organ       Date:  1994       Impact factor: 9.408

10.  Evaluation of microparticle enzyme immunoassays for immunoglobulins G and M to rubella virus and Toxoplasma gondii on the Abbott IMx automated analyzer.

Authors:  L E Schaefer; J W Dyke; F D Meglio; P R Murray; W Crafts; A C Niles
Journal:  J Clin Microbiol       Date:  1989-11       Impact factor: 5.948

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.