Literature DB >> 8205645

[Multicenter study of toxoplasma serology using various commercial ELISA reagents. Work Group Toxoplasmosis of the National Agency for Quality Control in Parasitology].

F Derouin1, Y J Garin, C Buffard, F Berthelot, J C Petithory.   

Abstract

A collaborative study conducted by the French National Agency for Quality Control in Parasitology (CNQP) and various manufacturers of ELISA kits, represented by the Association of Laboratory Reagent Manufacturers (SFRL) compared the toxoplasmosis IgG antibody titres obtained with different ELISA-IgG kits and determined the relationships between the titres obtained by these techniques and the titre defined in international units (IU). Fifty-one serum samples with toxoplasmosis antibody titres ranging from 0 to 900 IU were tested in two successive studies with 16 ELISA-IgG kits. For the negative sera, false-positive reactions were observed with one kit. For the positive sera, the titres observed in ELISA were generally higher than those expressed in IU. Above 250 IU, the very wide variability of the titres found with the different ELISA kits renders any comparative analysis impossible. For titres below 250 IU, the results are sufficiently homogeneous to permit the use of regression analysis to study how the results for each ELISA kit compare with the mean results for the other kits. The slope of the line of regression shows a tendency to over-titration or under-titration compared with the results of the other manufacturers; the ordinate at the origin reflects the positivity threshold of the reaction and can be used to assess the risk of a lack of sensitivity (high threshold) or of specificity (threshold too low). On the whole, the trends revealed for a given manufacturer are constant from one study to the other. Within this range of titres, regression analysis also reveals the general tendency of ELISA kits to overestimate the titres by comparison with immunofluorescence.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8205645      PMCID: PMC2486538     

Source DB:  PubMed          Journal:  Bull World Health Organ        ISSN: 0042-9686            Impact factor:   9.408


  7 in total

1.  [Quantitiative immunofluorescent antibody technic and serological diagnosis of toxoplasmosis: introduction of international units in the expression of positive results].

Authors:  G Niel; G Desmonts; M Gentilini
Journal:  Pathol Biol (Paris)       Date:  1973-02

2.  Evaluation of commercial serodiagnostic kits for toxoplasmosis.

Authors:  M Wilson; D A Ware; K W Walls
Journal:  J Clin Microbiol       Date:  1987-12       Impact factor: 5.948

3.  Evaluation of the enzyme-linked immunosorbent assay (ELISA) and other serological tests for the diagnosis of toxoplasmosis.

Authors:  Y Carlier; D Bout; J P Dessaint; A Capron; F Van Knapen; E J Ruitenberg; R Bergquist; G Huldt
Journal:  Bull World Health Organ       Date:  1980       Impact factor: 9.408

4.  [Value and limitations of toxoplasmosis serology in HIV patients].

Authors:  F Derouin; P Thulliez; Y J Garin
Journal:  Pathol Biol (Paris)       Date:  1991-04

5.  Five commercial enzyme linked immunosorbent assay kits for toxoplasma specific IgM antibody.

Authors:  D H Joynson; R A Payne; A H Balfour; E S Prestage; D G Fleck; B S Chessum
Journal:  J Clin Pathol       Date:  1989-06       Impact factor: 3.411

6.  Analysis of Toxoplasma gondii antigens recognized by human sera obtained before and after acute infection.

Authors:  I Potasman; F G Araujo; G Desmonts; J S Remington
Journal:  J Infect Dis       Date:  1986-10       Impact factor: 5.226

7.  Recent primary toxoplasma infection indicated by a low avidity of specific IgG.

Authors:  K Hedman; M Lappalainen; I Seppäiä; O Mäkelä
Journal:  J Infect Dis       Date:  1989-04       Impact factor: 5.226

  7 in total
  4 in total

1.  Performance of European laboratories testing serum samples for Toxoplasma gondii.

Authors:  J C Petithory; I Reiter-Owona; F Berthelot; M Milgram; J De Loye; E Petersen
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1996-01       Impact factor: 3.267

2.  [Serodiagnosis of toxoplasmosis: a comparative multicenter study of a standard scale through various actual tests and expression of the results in international units. Groupe de travail toxoplasmose du Contrôle national de qualité en parasotologie. Syndicat des fabricants de réactifs de laboratoire. Groupe de travail standardisation des tests sérologiques du Réseau européen de lutte contre la toxoplasmose congénitale].

Authors:  J C Petithory; P Ambroise-Thomas; J De Loye; H Pelloux; A Goullier-Fleuret; M Milgram; C Buffard; J P Garin
Journal:  Bull World Health Organ       Date:  1996       Impact factor: 9.408

Review 3.  Toxoplasma gondii: from animals to humans.

Authors:  A M Tenter; A R Heckeroth; L M Weiss
Journal:  Int J Parasitol       Date:  2000-11       Impact factor: 3.981

4.  A new IgG immunoblot kit for diagnosis of toxoplasmosis in pregnant women.

Authors:  Imen Khammari; Fatma Saghrouni; Sami Lakhal; Aida Bouratbine; Moncef Ben Said; Jalel Boukadida
Journal:  Korean J Parasitol       Date:  2014-10-22       Impact factor: 1.341

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.