| Literature DB >> 33196037 |
Elizabeth P Gurney1, Arden McAllister1, Britt Lang1, Courtney A Schreiber1, Sarita Sonalkar1.
Abstract
OBJECTIVE: The objective was to describe the sonographic position of copper intrauterine devices (IUDs) 6 months after insertion during cesarean delivery. STUDYEntities:
Keywords: Copper intrauterine device; Intrauterine device complication; Intrauterine device expulsion; Postpartum contraception; Postpartum intrauterine device; Postplacental intrauterine device
Year: 2020 PMID: 33196037 PMCID: PMC7644571 DOI: 10.1016/j.conx.2020.100040
Source DB: PubMed Journal: Contracept X ISSN: 2590-1516
Fig. 1Study flow: recruitment, enrollment and IUD status of individuals receiving TCu380A IUDs during cesarean delivery.
Demographic and baseline characteristics of subjects with TCu380A IUDs placed during cesarean delivery, reported by IUD position at 6 months postpartum
| Total | Correct IUD position | Other IUD position outcome | Outcome unknown | ||
|---|---|---|---|---|---|
| Age (years) | 27.9 ± 4.8 | 28.4 ± 5.2 | 28.5 ± 4.6 | 27.0 ± 4.8 | .84 |
| Race/ethnicity | |||||
| Black/African-American | 80 (73.4) | 27 (65.9) | 23 (82.1) | 30 (75.0) | .28 |
| White | 11 (10.1) | 4 (9.8) | 2 (7.1) | 5 (12.5) | |
| Other/unknown | 18 (16.5) | 10 (24.4) | 3 (10.7) | 5 (12.5) | |
| Annual household income | |||||
| <$10,000 | 29 (26.6) | 8 (19.5) | 7 (25.0) | 14 (35.0) | .82 |
| $10,000–$30,000 | 29 (26.6) | 14 (34.2) | 8 (28.6) | 7 (17.5) | |
| >$30,001 | 51 (46.8) | 19 (46.3) | 13 (46.4) | 19 (47.5) | |
| Parity | |||||
| 1 | 18 (16.5) | 6 (14.6) | 5 (17.9) | 7 (17.5) | .75 |
| ≥ 2 | 91 (83.5) | 35 (85.4) | 23 (82.1) | 33 (82.5) | |
| Relationship status | |||||
| Single | 41 (37.6) | 14 (34.2) | 13 (46.4) | 14 (35.0) | .52 |
| With partner | 34 (31.2) | 13 (31.7) | 6 (21.4) | 15 (37.5) | |
| Married or divorced | 34 (31.2) | 14 (34.2) | 9 (32.1) | 11 (27.5) | |
| BMI (kg/m2) | |||||
| 18–24.9 | 16 (14.7) | 7 (18.0) | 4 (14.8) | 5 (12.5) | .51 |
| ≥ 25 | 84 (77.1) | 32 (82.1) | 23 (85.2) | 29 (72.5) | |
| Gestational age | |||||
| Preterm (34 weeks 0 day–36 weeks 6 days) | 7 (6.4) | 4 (9.8) | 2 (7.1) | 1 (2.5) | .71 |
| Term (≥ 37 weeks 0 day) | 102 (93.6) | 37 (90.2) | 26 (92.9) | 39 (97.5) | |
| History of cesarean delivery | 75 (68.8) | 26 (63.4) | 20 (71.4) | 29 (72.5) | .61 |
Data are mean ± standard deviation or n (%).
Tests comparing distribution of characteristics for the groups “Correct IUD position” and “Other IUD position outcome.”
Positions of 69 TCu380A IUDs placed immediately after cesarean delivery and at 6 months postpartum
| Illustration of IUD position | Description | |
|---|---|---|
| 41 (59.4) | ||
| 6 (8.7) | ||
| 3 (4.3) | ||
| 10 (14.5) | ||
| 2 (2.9) | ||
| 3 (4.3) | ||
| 2 (2.9) |
Denominator to calculate proportions: n = 69 (participants with known IUD position outcome assessed with ultrasound).