Literature DB >> 33170374

Significance of implant design on the efficacy of different peri-implantitis decontamination protocols.

Ignacio Sanz-Martín1,2, Kyeongwon Paeng2, Hyobin Park2, Jae-Kook Cha3, Ui-Won Jung2, Mariano Sanz1,4.   

Abstract

OBJECTIVE: To assess the efficacy of three mechanical decontamination methods in four types of commercially available implants.
MATERIAL AND METHODS: Ninety-six implants of four commercial brands with different designs (regarding thread depth and thread pitch) were soaked in a surrogate biofilm (ink) and air-dried. Circumferential standardized peri-implant defects with 6 mm in depth and 1.55 mm in width were custom-made with a 3D printer. Stained implants were inserted in the defects and instrumented with three different methods: a titanium brush (TNB), a metallic ultrasonic tip (IST) and an air abrasive (PF). Standardized photographs were taken vertically to the implant axis (flat view), and with angulations of 60° (upper view) and 120° (lower view) to the implant long axis. The percentage of residual stain (PRS) was calculated with the image analysis software. Scanning electron microscope evaluations were performed on the buccal aspect of the implants at the central level of the defect.
RESULTS: The efficacy of PF was significantly inferior to the TNB and IST in all implant designs, while there were no significant differences between TNB and IST. IST showed significantly higher PRS in the implant with the highest thread pitch, while the TNB had the highest PRS in the implant with a marked reverse buttress-thread design. The micro-thread design had the lowest values of PRS for all decontamination methods. The apically facing threads represented the areas with highest PRS for all implant designs and decontamination methods.
CONCLUSION: Thread geometry influenced the access of the decontamination devices and in turn its efficacy. Implants with lower thread pitch and thread depth values appeared to have less residual staining. CLINICAL RELEVANCE: Clinicians must be aware of the importance of thread geometry in the decontamination efficacy.

Entities:  

Keywords:  Dental implants; Implant design; Peri-implantitis; Scanning electron microscope; Surface decontamination; Thread design

Year:  2020        PMID: 33170374     DOI: 10.1007/s00784-020-03681-y

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  4 in total

1.  An in vitro study of the treatment of implant surfaces with different instruments.

Authors:  R Mengel; C E Buns; C Mengel; L Flores-de-Jacoby
Journal:  Int J Oral Maxillofac Implants       Date:  1998 Jan-Feb       Impact factor: 2.804

2.  In vitro efficacy of three different implant surface decontamination methods in three different defect configurations.

Authors:  David Keim; Katrin Nickles; Bettina Dannewitz; Christoph Ratka; Peter Eickholz; Hari Petsos
Journal:  Clin Oral Implants Res       Date:  2019-05-08       Impact factor: 5.977

3.  The effect of five mechanical instrumentation protocols on implant surface topography and roughness: A scanning electron microscope and confocal laser scanning microscope analysis.

Authors:  Jae-Kook Cha; Kyeongwon Paeng; Ui-Won Jung; Seong-Ho Choi; Mariano Sanz; Ignacio Sanz-Martín
Journal:  Clin Oral Implants Res       Date:  2019-05-07       Impact factor: 5.977

4.  Conventional versus CO2 laser-assisted treatment of peri-implant defects with the concomitant use of pure-phase beta-tricalcium phosphate: a 5-year clinical report.

Authors:  Herbert Deppe; Hans-Henning Horch; Andreas Neff
Journal:  Int J Oral Maxillofac Implants       Date:  2007 Jan-Feb       Impact factor: 2.804

  4 in total
  3 in total

1.  Peri-Implantitis: Application of a Protocol for the Regeneration of Deep Osseous Defects. A Retrospective Case Series.

Authors:  Simone Verardi; Nicola Alberto Valente
Journal:  Int J Environ Res Public Health       Date:  2021-12-01       Impact factor: 3.390

2.  Erythritol air polishing in the surgical treatment of peri-implantitis: A randomized controlled trial.

Authors:  Diederik F M Hentenaar; Yvonne C M De Waal; Roy E Stewart; Arie Jan Van Winkelhoff; Henny J A Meijer; Gerry M Raghoebar
Journal:  Clin Oral Implants Res       Date:  2021-12-02       Impact factor: 5.021

3.  Reconstructive treatment of peri-implantitis infrabony defects of various configurations: 5-year survival and success.

Authors:  Mario Roccuzzo; Davide Mirra; Dario Pittoni; Guglielmo Ramieri; Andrea Roccuzzo
Journal:  Clin Oral Implants Res       Date:  2021-08-16       Impact factor: 5.021

  3 in total