Literature DB >> 9509785

An in vitro study of the treatment of implant surfaces with different instruments.

R Mengel1, C E Buns, C Mengel, L Flores-de-Jacoby.   

Abstract

The aim of this in vitro study using implants and abutments was to examine traces left by various cleaning instruments and to determine the quantity of substance removal. The implants and relevant abutments were Screw-Vent implants (Dentsply), titanium plasma-coated full-screw implants (Straumann), and standard Brånemark implants (Nobel Biocare). The instruments used were titanium curettes, Gracey curettes, plastic curettes, rubber cups with Zircate prophy paste, the Cavitron Jet ultrasonic scaler with universal inserts and airpolishing nozzles with Prophy-Jet cleaning powder, and the Densonic sonic scaler with SofTip disposable prophy tips and universal tips. Two test fields (2 x 2 mm) on the respective implant head and abutment underwent standard treatment with each instrument. With the full-screw implants, an additional two test fields were examined from the transition of the titanium plasma coating to the implant head. Untreated implants and abutment surfaces served as controls. The treated and untreated surfaces were examined by scanning electron microscopy for work traces and by optical laser profilometry for substance removal. The results showed that the Cavitron Jet ultrasonic unit, the Densonic sonic scaler with universal tips, and the Gracey curette left pronounced traces and induced high substance removal. The titanium curette and the Densonic sonic scaler with SofTip disposable prophy tips left virtually no traces and removed very little substance. The rubber cup, the plastic curette, and the Cavitron Jet airpolishing system left the implant surfaces unchanged. All instruments apart from the rubber cup and Cavitron Jet airpolishing system left pronounced traces at the transition of the implant head to the titanium plasma coating of the full-screw implants. The Cavitron Jet airpolishing system, the rubber cup, the plastic curette, and, with some reservations, the Densonic sonic scaler with SofTip plastic fittings and the titanium curette, appear to be suitable for cleaning implant surfaces.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9509785

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  14 in total

1.  Influence of different treatment approaches on the removal of early plaque biofilms and the viability of SAOS2 osteoblasts grown on titanium implants.

Authors:  Frank Schwarz; Anton Sculean; Georg Romanos; Monika Herten; Nadine Horn; Werner Scherbaum; Jürgen Becker
Journal:  Clin Oral Investig       Date:  2005-04-20       Impact factor: 3.573

2.  Surface scratch assessment of titanium implant abutments and cementum following instrumentation with metal curettes.

Authors:  P M Anastassiadis; C Hall; V Marino; P M Bartold
Journal:  Clin Oral Investig       Date:  2014-05-23       Impact factor: 3.573

3.  Taurolidine as an effective and biocompatible additive for plaque-removing techniques on implant surfaces.

Authors:  Gordon John; Frank Schwarz; Jürgen Becker
Journal:  Clin Oral Investig       Date:  2014-10-28       Impact factor: 3.573

4.  Significance of implant design on the efficacy of different peri-implantitis decontamination protocols.

Authors:  Ignacio Sanz-Martín; Kyeongwon Paeng; Hyobin Park; Jae-Kook Cha; Ui-Won Jung; Mariano Sanz
Journal:  Clin Oral Investig       Date:  2020-11-10       Impact factor: 3.573

5.  Biological response of human bone marrow stromal cells to sandblasted titanium nitride-coated implant surfaces.

Authors:  Marco Annunziata; Luigi Guida; Letizia Perillo; Raffaella Aversa; Irene Passaro; Adriana Oliva
Journal:  J Mater Sci Mater Med       Date:  2008-07-16       Impact factor: 3.896

Review 6.  Implant Maintenance: A Clinical Update.

Authors:  Minkle Gulati; Vivek Govila; Vishal Anand; Bhargavi Anand
Journal:  Int Sch Res Notices       Date:  2014-07-09

7.  A novel non-surgical method for mild peri-implantitis- a multicenter consecutive case series.

Authors:  J C Wohlfahrt; B J Evensen; B Zeza; H Jansson; A Pilloni; A M Roos-Jansåker; G L Di Tanna; A M Aass; M Klepp; O C Koldsland
Journal:  Int J Implant Dent       Date:  2017-08-03

8.  A comparison of retentive strength of implant cement depending on various methods of removing provisional cement from implant abutment.

Authors:  Eun-Cheol Keum; Soo-Yeon Shin
Journal:  J Adv Prosthodont       Date:  2013-08-31       Impact factor: 1.904

9.  Detoxification of implant surfaces affected by peri-implant disease: an overview of surgical methods.

Authors:  Pilar Valderrama; Thomas G Wilson
Journal:  Int J Dent       Date:  2013-08-04

10.  Detoxification of Implant Surfaces Affected by Peri-Implant Disease: An Overview of Non-surgical Methods.

Authors:  Pilar Valderrama; Jonathan A Blansett; Mayra G Gonzalez; Myrna G Cantu; Thomas G Wilson
Journal:  Open Dent J       Date:  2014-05-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.