Literature DB >> 31022305

The effect of five mechanical instrumentation protocols on implant surface topography and roughness: A scanning electron microscope and confocal laser scanning microscope analysis.

Jae-Kook Cha1, Kyeongwon Paeng1, Ui-Won Jung1, Seong-Ho Choi1, Mariano Sanz2,3, Ignacio Sanz-Martín2.   

Abstract

OBJECTIVE: To evaluate in vitro the changes in implant surface topography and roughness of commercial implants after instrumentation with five decontamination protocols.
MATERIAL AND METHODS: Seventy-two titanium implants with a sandblasted and acid-etched (SLA) surface were placed 5 mm supra-crestally. Five groups of twelve implants were instrumented with the following protocols: a metal scaler tip (SCAL), a thermoplastic scaler tip (PEEK), a round titanium brush (RBRU), a tufted brush with titanium bristles (TNBRU), and a glycine-based air-powder abrasive (GLYC). A sixth group with untreated implants was used as control. Scanning electron microscope and confocal laser scanning microscope were utilized to evaluate the changes in the implant surfaces.
RESULTS: The SCAL caused pronounced macroscopic alterations and damage of the implant surface, the PEEK left remnants of the plastic tip in the implant surface, and both titanium brush groups flattened the thread profile, while minimal alterations were observed in the GLYC. When compared to the control group, the roughness parameters (Sa) in the buccal aspect increased in the thread area of SCAL, and a minor reduction was observed in the PEEK while in the other groups, these values remained unchanged. In the valley areas, however the RBRU, TNBRU, and GLYC experienced a significant reduction (smoothening) indicating different accessibility of the decontamination protocols to the thread and valley. Similarly, the buccal aspects had more pronounced changes than those in the palatal aspect.
CONCLUSION: Within the limitations of this in vitro investigation, the tested protocols induced different macroscopic alterations and surface roughness changes that varied in the thread and valley area.
© 2019 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  confocal microscope; dental implants; peri-implantitis; scanning electron microscope; surface decontamination; surface macrotopography; titanium

Mesh:

Substances:

Year:  2019        PMID: 31022305     DOI: 10.1111/clr.13446

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  11 in total

1.  Significance of implant design on the efficacy of different peri-implantitis decontamination protocols.

Authors:  Ignacio Sanz-Martín; Kyeongwon Paeng; Hyobin Park; Jae-Kook Cha; Ui-Won Jung; Mariano Sanz
Journal:  Clin Oral Investig       Date:  2020-11-10       Impact factor: 3.573

2.  [Efficacy of combined application of glycine powder air-polishing in non-surgical treatment of peri-implant diseases].

Authors:  F Sun; S Q Li; Y P Wei; J S Zhong; C Wang; W J Hu
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2022-02-18

3.  Comparison of decontamination efficacy of two electrolyte cleaning methods to diode laser, plasma, and air-abrasive devices.

Authors:  Holger Zipprich; Paul Weigl; Riccardo Di Gianfilippo; Larissa Steigmann; Dirk Henrich; Hom-Lay Wang; Markus Schlee; Christoph Ratka
Journal:  Clin Oral Investig       Date:  2022-03-24       Impact factor: 3.573

Review 4.  The unfavorable role of titanium particles released from dental implants.

Authors:  Zilan Zhou; Quan Shi; Jie Wang; Xiaohang Chen; Yujia Hao; Yuan Zhang; Xing Wang
Journal:  Nanotheranostics       Date:  2021-03-10

5.  A micromorphological/microbiological pilot study assessing three methods for the maintenance of the implant patient.

Authors:  Elisabetta Polizzi; Bianca D'orto; Simone Tomasi; Giulia Tetè
Journal:  Clin Exp Dent Res       Date:  2020-11-19

6.  Antibacterial Effect of Functionalized Polymeric Nanoparticles on Titanium Surfaces Using an In Vitro Subgingival Biofilm Model.

Authors:  Jaime Bueno; Leire Virto; Manuel Toledano-Osorio; Elena Figuero; Manuel Toledano; Antonio L Medina-Castillo; Raquel Osorio; Mariano Sanz; David Herrera
Journal:  Polymers (Basel)       Date:  2022-01-18       Impact factor: 4.329

7.  Effects of implant surface mechanical instrumentation methods on peri-implantitis: An in vitro study using a circumferential bone defect model.

Authors:  Motohiro Munakata; Akihiro Suzuki; Kikue Yamaguchi; Yu Kataoka; Minoru Sanda
Journal:  J Dent Sci       Date:  2021-09-14       Impact factor: 3.719

8.  In vitro surgical and non-surgical air-polishing efficacy for implant surface decontamination in three different defect configurations.

Authors:  Otto Zuhr; Hari Petsos; Vivian Tuchscheerer; Peter Eickholz; Bettina Dannewitz; Christoph Ratka
Journal:  Clin Oral Investig       Date:  2020-08-19       Impact factor: 3.573

9.  The Effects of Ultrasonic Scaling and Air-Abrasive Powders on the Decontamination of 9 Implant-Abutment Surfaces: Scanning Electron Analysis and In Vitro Study.

Authors:  Francesco Gianfreda; Patrizio Bollero; Maurizio Muzzi; Andrea Di Giulio; Eleonora Nicolai; Luigi Canullo
Journal:  Dent J (Basel)       Date:  2022-03-01

10.  Ultrastructural changes of smooth and rough titanium implant surfaces induced by metal and plastic periodontal probes.

Authors:  Matthias Folwaczny; Torsten Rudolf; Iris Frasheri; Madlena Betthäuser
Journal:  Clin Oral Investig       Date:  2020-06-21       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.