Literature DB >> 33163989

Grating-based Spectral CT using Small Angle X-ray Beam Deflections.

J Webster Stayman1, Matthew Tivnan1, Grace J Gang1, Wenying Wang1, Nadav Shapira2, Peter B Noël2.   

Abstract

Interest in spectral CT for diagnostics and therapy evaluation has been growing. Acquisitions of data from distinct energy spectra provide, among other advantages, quantitative density estimations for multiple materials. We introduce a novel spectral CT concept that includes a fine-pitch grating for prefiltration of the x-ray beam. The attenuation behavior of this grating changes significantly if x-rays are slightly angled in relation to the grating structures. To apply such an angle (i.e. switch between the different filtrations) we propose a fast, controllable, and precise solution by moving the focal spot of the x-ray tube. In this work, we performed preliminary evaluations with a grating prototype on a CT test bench. Our results include x-ray spectrometer measurements that reveal diverse and controllable spectral shaping between 4° and 6° for a specific grating design. Additional experiments with a contrast agent phantom illustrated the capability to decompose clinically relevant iodine concentrations (5, 10, 20, and 50mg/mL) - demonstrating the feasibility of the grating-based approach. Ongoing and future studies will investigate the potential of this novel concept as a relatively simple upgrade to standard energy-integrating CT.

Entities:  

Keywords:  Spectral CT; adaptive imaging; dual energy CT; material decomposition; quantitative CT

Year:  2020        PMID: 33163989      PMCID: PMC7643889     

Source DB:  PubMed          Journal:  Conf Proc Int Conf Image Form Xray Comput Tomogr


  14 in total

1.  Dynamic fluence field modulation in computed tomography using multiple aperture devices.

Authors:  Grace J Gang; Andrew Mao; Wenying Wang; Jeffrey H Siewerdsen; Aswin Mathews; Satomi Kawamoto; Reuven Levinson; J Webster Stayman
Journal:  Phys Med Biol       Date:  2019-05-21       Impact factor: 3.609

2.  K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors.

Authors:  E Roessl; R Proksa
Journal:  Phys Med Biol       Date:  2007-07-17       Impact factor: 3.609

3.  Spectral Photon-counting CT: Initial Experience with Dual-Contrast Agent K-Edge Colonography.

Authors:  Daniela Muenzel; Daniel Bar-Ness; Ewald Roessl; Ira Blevis; Matthias Bartels; Alexander A Fingerle; Stefan Ruschke; Philippe Coulon; Heiner Daerr; Felix K Kopp; Bernhard Brendel; Axel Thran; Michal Rokni; Julia Herzen; Loic Boussel; Franz Pfeiffer; Roland Proksa; Ernst J Rummeny; Philippe Douek; Peter B Noël
Journal:  Radiology       Date:  2016-12-02       Impact factor: 11.105

4.  Dual-contrast agent photon-counting computed tomography of the heart: initial experience.

Authors:  Rolf Symons; Tyler E Cork; Manu N Lakshmanan; Robert Evers; Cynthia Davies-Venn; Kelly A Rice; Marvin L Thomas; Chia-Ying Liu; Steffen Kappler; Stefan Ulzheimer; Veit Sandfort; David A Bluemke; Amir Pourmorteza
Journal:  Int J Cardiovasc Imaging       Date:  2017-03-13       Impact factor: 2.357

5.  Split-filter computed tomography: a simple technique for dual energy scanning.

Authors:  B Rutt; A Fenster
Journal:  J Comput Assist Tomogr       Date:  1980-08       Impact factor: 1.826

6.  Feasibility of multi-contrast imaging on dual-source photon counting detector (PCD) CT: An initial phantom study.

Authors:  Shengzhen Tao; Kishore Rajendran; Cynthia H McCollough; Shuai Leng
Journal:  Med Phys       Date:  2019-07-05       Impact factor: 4.071

7.  Optimized Spatial-Spectral CT for Multi-Material Decomposition.

Authors:  Matthew Tivnan; Wenying Wang; Steven Tilley; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2019-05-28

8.  Bone mineral density measurements in vertebral specimens and phantoms using dual-layer spectral computed tomography.

Authors:  Kai Mei; Benedikt J Schwaiger; Felix K Kopp; Sebastian Ehn; Alexandra S Gersing; Jan S Kirschke; Daniela Muenzel; Alexander A Fingerle; Ernst J Rummeny; Franz Pfeiffer; Thomas Baum; Peter B Noël
Journal:  Sci Rep       Date:  2017-12-13       Impact factor: 4.379

9.  Multicolor spectral photon-counting computed tomography: in vivo dual contrast imaging with a high count rate scanner.

Authors:  David P Cormode; Salim Si-Mohamed; Daniel Bar-Ness; Monica Sigovan; Pratap C Naha; Joelle Balegamire; Franck Lavenne; Philippe Coulon; Ewald Roessl; Matthias Bartels; Michal Rokni; Ira Blevis; Loic Boussel; Philippe Douek
Journal:  Sci Rep       Date:  2017-07-06       Impact factor: 4.379

10.  Experimental feasibility of spectral photon-counting computed tomography with two contrast agents for the detection of endoleaks following endovascular aortic repair.

Authors:  Julia Dangelmaier; Daniel Bar-Ness; Heiner Daerr; Daniela Muenzel; Salim Si-Mohamed; Sebastian Ehn; Alexander A Fingerle; Melanie A Kimm; Felix K Kopp; Loic Boussel; Ewald Roessl; Franz Pfeiffer; Ernst J Rummeny; Roland Proksa; Philippe Douek; Peter B Noël
Journal:  Eur Radiol       Date:  2018-02-19       Impact factor: 5.315

View more
  1 in total

1.  Hepatic dual-contrast CT imaging: slow triple kVp switching CT with CNN-based sinogram completion and material decomposition.

Authors:  Wenchao Cao; Nadav Shapira; Andrew Maidment; Heiner Daerr; Peter B Noël
Journal:  J Med Imaging (Bellingham)       Date:  2022-01-31
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.