Literature DB >> 27918709

Spectral Photon-counting CT: Initial Experience with Dual-Contrast Agent K-Edge Colonography.

Daniela Muenzel1, Daniel Bar-Ness1, Ewald Roessl1, Ira Blevis1, Matthias Bartels1, Alexander A Fingerle1, Stefan Ruschke1, Philippe Coulon1, Heiner Daerr1, Felix K Kopp1, Bernhard Brendel1, Axel Thran1, Michal Rokni1, Julia Herzen1, Loic Boussel1, Franz Pfeiffer1, Roland Proksa1, Ernst J Rummeny1, Philippe Douek1, Peter B Noël1.   

Abstract

Purpose To investigate the feasibility of using spectral photon-counting computed tomography (CT) to differentiate between gadolinium-based and nonionic iodine-based contrast material in a colon phantom by using the characteristic k edge of gadolinium. Materials and Methods A custom-made colon phantom was filled with nonionic iodine-based contrast material, and a gadolinium-filled capsule representing a contrast material-enhanced polyp was positioned on the colon wall. The colon phantom was scanned with a preclinical spectral photon-counting CT system to obtain spectral and conventional data. By fully using the multibin spectral information, material decomposition was performed to generate iodine and gadolinium maps. Quantitative measurements were performed within the lumen and polyp to quantitatively determine the absolute content of iodine and gadolinium. Results In a conventional CT section, absorption values of both contrast agents were similar at approximately 110 HU. Contrast material maps clearly differentiated the distributions, with gadolinium solely in the polyp and iodine in the lumen of the colon. Quantitative measurements of contrast material concentrations in the colon and polyp matched well with those of actual prepared mixtures. Conclusion Dual-contrast spectral photon-counting CT colonography with iodine-filled lumen and gadolinium-tagged polyps may enable ready differentiation between polyps and tagged fecal material. © RSNA, 2016.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27918709     DOI: 10.1148/radiol.2016160890

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  44 in total

1.  Quantification of multiple mixed contrast and tissue compositions using photon-counting spectral computed tomography.

Authors:  Tyler E Curtis; Ryan K Roeder
Journal:  J Med Imaging (Bellingham)       Date:  2019-02-11

2.  Impact of prior information on material decomposition in dual- and multienergy computed tomography.

Authors:  Liqiang Ren; Shengzhen Tao; Kishore Rajendran; Cynthia H McCollough; Lifeng Yu
Journal:  J Med Imaging (Bellingham)       Date:  2019-03-14

Review 3.  Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology.

Authors:  Shuai Leng; Michael Bruesewitz; Shengzhen Tao; Kishore Rajendran; Ahmed F Halaweish; Norbert G Campeau; Joel G Fletcher; Cynthia H McCollough
Journal:  Radiographics       Date:  2019 May-Jun       Impact factor: 5.333

4.  Dual-source multienergy CT with triple or quadruple x-ray beams.

Authors:  Lifeng Yu; Liqiang Ren; Zhoubo Li; Shuai Leng; Cynthia H McCollough
Journal:  J Med Imaging (Bellingham)       Date:  2018-07-24

5.  Quantitative accuracy and dose efficiency of dual-contrast imaging using dual-energy CT: a phantom study.

Authors:  Liqiang Ren; Kishore Rajendran; Cynthia H McCollough; Lifeng Yu
Journal:  Med Phys       Date:  2019-12-10       Impact factor: 4.071

6.  Radiation dose efficiency of multi-energy photon-counting-detector CT for dual-contrast imaging.

Authors:  Liqiang Ren; Kishore Rajendran; Cynthia H McCollough; Lifeng Yu
Journal:  Phys Med Biol       Date:  2019-12-13       Impact factor: 3.609

7.  Photon-counting CT for simultaneous imaging of multiple contrast agents in the abdomen: An in vivo study.

Authors:  Rolf Symons; Bernhard Krauss; Pooyan Sahbaee; Tyler E Cork; Manu N Lakshmanan; David A Bluemke; Amir Pourmorteza
Journal:  Med Phys       Date:  2017-08-20       Impact factor: 4.071

8.  Improving iodine contrast to noise ratio using virtual monoenergetic imaging and prior-knowledge-aware iterative denoising (mono-PKAID).

Authors:  Shengzhen Tao; Kishore Rajendran; Wei Zhou; Joel G Fletcher; Cynthia H McCollough; Shuai Leng
Journal:  Phys Med Biol       Date:  2019-05-16       Impact factor: 3.609

Review 9.  Nanoparticle contrast agents for X-ray imaging applications.

Authors:  Jessica C Hsu; Lenitza M Nieves; Oshra Betzer; Tamar Sadan; Peter B Noël; Rachela Popovtzer; David P Cormode
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2020-05-22

10.  Photon-counting computed tomography of lanthanide contrast agents with a high-flux 330-μm-pitch cadmium zinc telluride detector in a table-top system.

Authors:  Chelsea A S Dunning; Jericho O'Connell; Spencer M Robinson; Kevin J Murphy; Adriaan L Frencken; Frank C J M van Veggel; Kris Iniewski; Magdalena Bazalova-Carter
Journal:  J Med Imaging (Bellingham)       Date:  2020-06-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.