| Literature DB >> 33096872 |
Silvijus Abramavičius1, Mantas Venslauskas2, Antanas Vaitkus3, Vaidotas Gudžiūnas1,2, Ovidijus Laucius1, Edgaras Stankevičius1.
Abstract
Background and objectives: tremor is an unintentional and rhythmic movement of any part of the body that is a typical symptom of Essential Tremor (ET). ET impairs the quality of life of patients and is treated with pharmacotherapy. We investigated the tremor reduction efficacy of an innovative vibrational medical device (IMD) in ET patients. Materials andEntities:
Keywords: essential tremor; essential tremor treatment; local hand-arm vibration; mechanical vibration; vibrational therapy
Mesh:
Year: 2020 PMID: 33096872 PMCID: PMC7589646 DOI: 10.3390/medicina56100552
Source DB: PubMed Journal: Medicina (Kaunas) ISSN: 1010-660X Impact factor: 2.430
Figure 1The Vilim ball device.
Figure 2Secondary efficacy endpoint.
Inclusion and exclusion criteria.
| Inclusion Criteria |
|---|
|
Male and female subjects 18–65 years of age at the time of consent; Written informed consent provided by the patient; Patients diagnosed with essential tremor. |
|
|
|
Non-compliance; Substance-dependence; Uncontrolled medical illness (arterial hypertension, diabetes, severe liver or kidney failure); Subjects with following abnormal laboratory values at screening visit:
Hemoglobin < 11.0 g/dL (<110.0 g/L) or hematocrit < 30% (<0.30 White blood cell count <3.0 × 109/L (<3000/mm3), Absolute neutrophil count of <1.5 × 109/L (<1500/mm3), Absolute lymphocyte count of <0.5 × 109/L (<500/mm3), Platelet count < 100 × 109/L, Estimated creatinine clearance < 40 mL/min based on the Cockcroft–Gault calculation or serum creatinine value greater than 1.5 times the upper limit of normal (ULN), Aspartate aminotransferase (AST) or alanine aminotransferase (ALT) values greater than 2 times the upper limit of normal, Subject has positive results for hepatitis B surface antigens (HBsAg), antibodies to hepatitis B core antigens (anti-HBc), hepatitis C virus (HCV), or human immunodeficiency virus (HIV); Other subjects who, in the opinion of the investigator, have any acute or chronic medical or psychiatric condition or laboratory abnormality at the screening that would impair the subject’s capability to follow the study protocol. |
IMD (investigated medical device) effectiveness and baseline tremor intensity as reported by patients.
| Tremor Increased Slightly | Tremor Did Not Change | Tremor Decreased Slightly | |
|---|---|---|---|
| Tremor occurs only upon stressful situation | 0 | 0 | 1 |
| Tremor impairs my ability to perform some routine tasks that I was previously capable of performing | 0 | 4 | 3 |
| Tremor intensity has significantly impaired my ability to perform daily tasks | 2 | 3 | 3 |