| Literature DB >> 33083552 |
Emilio Pedrotti1, Francesco Carones2, Pietro Talli3, Erika Bonacci1, Federico Selvi4, Alice Galzignato1, Andrea Besutti1, Alessandra De Gregorio5, Giorgio Marchini1.
Abstract
OBJECTIVE: To evaluate objective and subjective outcomes after bilateral implantation of two different multifocal intraocular lenses, which correct pseudophakic presbyopia in an adequate and homogeneous population court. METHODS AND ANALYSIS: Fifty patients were evaluated at 3 months after bilateral implantation, at the Eye Clinic of University of Verona and at the Carones Ophthalmology Center Milano, as follows: Tecnis Symfony (25 patients), Alcon PanOptix (25 patients). Main outcomes were uncorrected and best-corrected distance visual acuity (UDVA and BCVA) at 4 m, 60 cm (best distance corrected intermediate visual acuity (BDCIVA) and uncorrected intermediate visual acuity), 40 cm (best distance corrected near visual acuity (BDCNVA) and uncorrected near visual acuity (UNVA)), objective refractive outcome, defocus curve, contrast sensitivity (Modulation Transfer Function (MTF) cut-off), optical quality (Strehl ratio), aberrometry (root mean square RMS 4 mm), subjective quality of life (National Eye Institute Refractive Error Quality of Life score (NEI-RQL-42 score) test).Entities:
Keywords: optics and refraction; visual perception
Year: 2020 PMID: 33083552 PMCID: PMC7559032 DOI: 10.1136/bmjophth-2020-000497
Source DB: PubMed Journal: BMJ Open Ophthalmol ISSN: 2397-3269
Preoperative patient’s characteristics in the two IOL groups
| Sample features before surgery | P value | ||
| Extended Depth of Focus IOL mean (SD) (25 patients) | Enlighten IOL mean (SD) (25 patients) | ||
| Age (years), mean (SD) | 70.16±4.4 | 72.12±3.25 | >0.05 |
| SE (D), mean (SD) | −0.45±3.25 | −2.01±0.2 | >0.05 |
| Preoperative CDVA (logMar), mean (SD) | 0.456±0.32 | 0.26±0.4 | >0.05 |
| AL (mm), mean (SD) | 23.21±1.2 | 23.87±2.5 | >0.05 |
| K1 (D), mean (SD) | 43.99±1.88 | 43.17±3.8 | >0.05 |
| K2 (D), mean (SD) | 44.41±3.25 | 43.87±1.3 | >0.05 |
| IOL power (D), mean (SD) | 21.83±4.5 | 21.02±2.86 | >0.05 |
| Photopic pupil size (mm), mean (SD) | 3.28±0.3 | 3.16±0.20 | >0.05 |
| Scotopic pupil size (mm), mean (SD) | 5.02±0.4 | 5.11±0.3 | >0.05 |
AL, Axial Lenght; CDVA, Corrected Distance Visual Acuity; EDOF, Extended Depth of Focus; IOL, intraocular lens; SE, spherical equivalent.
Visual acuity at several distances at 3 months after bilateral implantation
| Postoperative visual acuity | |||
| Extended Depth of Focus IOL | Enlighten IOL | P value | |
| 0.489 | |||
| Mean±SD | −0.09 (0.05) | −0.08 (0.06) | |
| Median (range) | −0.08 (-0.18 to 0.02) | −0.10 (-0.18 to 0.04) | |
| 0.058 | |||
| Mean±SD | 0.10 (0.03) | 0.12 (0.04) | |
| Median (range) | 0.10 (0.02 to 0.14) | 0.12 (0.06 to 0.20) | |
| Mean±SD | 0.07 (0.03) | 0.10 (0.03) | 0.001 |
| Median (range) | 0.08 (0.00 to 0.08) | 0.10 (0.04 to 0.18) | |
| 0.001 | |||
| Mean±SD | 0.26 (0.08) | 0.14 (0.05) | |
| Median (range) | 0.24 (0.14 to 0.32) | 0.14 (0.02 to 0.20) | |
| 0.001 | |||
| Mean±SD | 0.26 (0.05) | 0.14 (0.04) | |
| Median (range) | 0.26 (0.16 to 0.36) | 0.14 (0.06 to 0.20) | |
BDCIVA, best distance corrected intermediate visual acuity; BDCNVA, best distance corrected near visual acuity; BDCVA, best distance corrected visual acuity; UDVA, uncorrected distance visual acuity; UIVA, uncorrected intermediate visual acuity; UNVA, uncorrected near visual acuity.
Figure 1Defocus curve. The defocus curve, according to visual acuity at several distances, presented significant differences at −1.50 D and at −2.50 D.
Objective postoperative quality of vision
| Postoperative quality of vision | |||
| A | B | P value | |
| 0.258 | |||
| Mean (SD) | 0.17 (0.05) | 0.15 (0.08) | |
| Median (range) | 0.1 (0.001 to 0.272) | 0.12 (0.07 to 0.4) | |
| 0.024 | |||
| Mean (SD) | 0.15 (0.06) | 0.18 (0.06) | |
| Median (range) | 0.18 (0.05 to 0.46) | 0.2 (0.08 to 0.33) | |
| 0.041 | |||
| Mean (SD) | 34.25 (11.8) | 27.41 (13.5) | |
| Median | 36.69 | 22.2 | |
MTF, Modulation Transfer Function; RMS, root mean square.
Subjective quality of vision by means of NEI-RQL-42 score
| Subjective quality of vision NEI-RQL-42 score | ||
| Extended Depth of Focus IOL | Enlighten IOL | |
| Clarity of vision | 92.01 (10.41) | 88.75 (18.53) |
| 91.66 (56.25 to 100) | 100 (44.4 to 100) | |
| Expectations | 61.49 (36.44) | 70.83 (43.10) |
| 74 (0 to 100) | 100 (0.00 to 100) | |
| Near vision | 86.11 (15.89) | 90.81 (16.00) |
| 83.33 (39.58 to 100) | 91.75 (33.3 to 100) | |
| Far vision | 87.65 (13.18) | 84.50 (14.90) |
| 88.33 (45 to 100) | 89.16 (39.98 to 100) | |
| Diurnal fluctuations | 80.71 (24.21) | 82.98 (22.67) |
| 87.50 (12.5 to 100) | 93.75 (29.75 to 100) | |
| Dependence on correction | 62.96 (35.37) | 95 (9.21) |
| 75 (0 to 100) | 100 (100 to 75) | |
| Symptoms | 75.75 (16.09) | 79.73 (19.99) |
| 79.83 (35 to 100) | 91 (35.8 to 100) | |
| Suboptimal correction | 91.20 (18.33) | 100 (0) |
| 100 (50 to 100) | 100 (100 to 100) | |
NEI-RQL-42, National Eye Institute Refractive Error Quality of Life score.