Literature DB >> 30089179

A Comparative Evaluation of a New Generation of Diffractive Trifocal and Extended Depth of Focus Intraocular Lenses.

Beatrice Cochener, Guillaume Boutillier, Mathieu Lamard, Claire Auberger-Zagnoli.   

Abstract

PURPOSE: To evaluate and compare the performance of two diffractive trifocal and one extended depth of focus (EDOF) intraocular lenses (IOLs).
METHODS: In this 6-month, single-center, prospective, randomized, comparative study, patients undergoing routine cataract surgery were randomized to receive one of two trifocal IOLs (AcrySof IQ PanOptix; Alcon Laboratories, Inc., Fort Worth, TX, or FineVision Micro F; PhysIOL SA, Liège, Belgium) or an EDOF IOL (TECNIS Symfony; Abbott Medical Optics, Inc., Abbott Park, IL). There were 20 patients in each group. The primary outcome was binocular and monocular uncorrected distance (UDVA), intermediate (UIVA), and near (UNVA) visual acuity. The secondary outcomes were quality of vision and aberrometry.
RESULTS: There was no statistically significant difference between groups in either monocular (P = .717) or binocular (P = .837) UDVA. Monocular and binocular UNVA were statistically and significantly better for both trifocal lenses than for the EDOF IOL (P = .002). The percentage of patients with J2 UNVA was 52.5% monocularly and 70% binocularly for the TECNIS Symfony IOL, 81.5% monocularly and 100% binocularly for the AcrySof IQ PanOptix IOL, and 82.5% monocularly and 95% binocularly for the FineVision Micro F IOL. There was no significant difference in binocular UIVA between groups; VA was better than 0.6 in 55%, 53%, and 35% of patients with the TECNIS Symfony, AcrySof IQ Pan-Optix, and FineVision Micro F IOLs, respectively. Overall, 90% patients achieved spectacle independence. There were no differences in visual symptoms and aberrometry among groups.
CONCLUSIONS: All three IOLs provided good visual acuity at all distances, a high percentage of spectacle independence, and little or no impact of visual symptoms on the patients' daily functioning. Near vision was statistically better for both trifocal IOLs compared to the EDOF IOL. [J Refract Surg. 2018;34(8):507-514.]. Copyright 2018, SLACK Incorporated.

Entities:  

Mesh:

Year:  2018        PMID: 30089179     DOI: 10.3928/1081597X-20180530-02

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  45 in total

1.  Presbyopic lens exchange (PRELEX) cataract surgery outcomes with implantation of a rotationally asymmetric refractive multifocal intraocular lens: femtosecond laser-assisted versus manual phacoemulsification.

Authors:  Peter Žiak; Juraj Halička; Peter Mojžiš; Karolína Kapitánová; Javorka Michal; David P Piñero
Journal:  Int Ophthalmol       Date:  2019-06-05       Impact factor: 2.031

2.  Optical design and performance of a trifocal sinusoidal diffractive intraocular lens.

Authors:  Fidel Vega; Maite Valentino; Franco Rigato; María S Millán
Journal:  Biomed Opt Express       Date:  2021-05-12       Impact factor: 3.732

3.  Visual Outcomes and Optical Quality of Accommodative, Multifocal, Extended Depth-of-Focus, and Monofocal Intraocular Lenses in Presbyopia-Correcting Cataract Surgery: A Systematic Review and Bayesian Network Meta-analysis.

Authors:  Jeong-Yeon Cho; Yeo Kyoung Won; Jongyeop Park; Jin Hyun Nam; Ji-Yoon Hong; Serim Min; Nahyun Kim; Tae-Young Chung; Eui-Kyung Lee; Sun-Hong Kwon; Dong Hui Lim
Journal:  JAMA Ophthalmol       Date:  2022-09-22       Impact factor: 8.253

4.  Comparisons of visual outcomes between bilateral implantation and mix-and-match implantation of three types intraocular lenses.

Authors:  Shurui Ke; Wenjuan Wan; Can Li
Journal:  Int Ophthalmol       Date:  2022-09-20       Impact factor: 2.029

5.  Visual and Refractive Outcomes and Patient Satisfaction Following Implantation of Monofocal IOL in One Eye and ERV IOL in the Contralateral Eye with Mini-Monovision.

Authors:  Sheetal Brar; Sri Ganesh; Raghavender Reddy Arra; Smith Snehal Sute
Journal:  Clin Ophthalmol       Date:  2021-05-04

6.  Reported Patient Satisfaction and Spectacle Independence Following Bilateral Implantation of the PanOptix® Trifocal Intraocular Lens.

Authors:  Clayton Blehm; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2021-07-06

7.  Spectacle Independence and Quality of Vision After Bilateral Implantation of a Trifocal Intraocular Lens.

Authors:  Andrew C Shatz; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2021-06-17

8.  Comparison of the Clinical Outcomes between Echelette Extended Range of Vision and Diffractive Bifocal Intraocular Lenses.

Authors:  Xin Liu; Xiaohui Song; Wei Wang; Yanan Zhu; Danni Lyu; Xingchao Shentu; Peiqing Chen; Yibo Yu; Ke Yao
Journal:  J Ophthalmol       Date:  2019-09-23       Impact factor: 1.909

9.  Comparison of the Visual Outcomes of an Extended Depth-of-Focus Lens and a Trifocal Lens.

Authors:  Majid Moshirfar; James Ellis; Daniel Beesley; Shannon E McCabe; Adam Lewis; William B West; Yasmyne Ronquillo; Phillip Hoopes
Journal:  Clin Ophthalmol       Date:  2021-07-16

10.  Visual Performances of a New Extended Depth-of-Focus Intraocular Lens with a Refractive Design: A Prospective Study After Bilateral Implantation.

Authors:  Leopoldo Spadea; Maria Ilaria Giannico; Martina Formisano; Ludovico Alisi
Journal:  Ther Clin Risk Manag       Date:  2021-07-16       Impact factor: 2.423

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.