Literature DB >> 33065559

Noise reduction in CT image using prior knowledge aware iterative denoising.

Shengzhen Tao1, Kishore Rajendran2, Wei Zhou2, Joel G Fletcher2, Cynthia H McCollough2, Shuai Leng2.   

Abstract

The clinical demand for low image noise often limits the slice thickness used in many CT applications. However, a thick-slice image is more susceptible to longitudinal partial volume effects, which can blur key anatomic structures and pathologies of interest. In this work, we develop a prior knowledge aware iterative denoising (PKAID) framework that utilizes spatial data redundancy in the slice increment direction to generate low-noise, thin-slice images, and demonstrate its application in non-contrast head CT exams. The proposed technique takes advantage of the low noise of thicker images and exploits the structural similarity between the thick- and thin-slice images to reduce noise in the thin-slice image. Phantom data and patient cases (n= 3) of head CT were used to assess performance of this method. Images were reconstructed at clinically utilized slice thickness (5 mm) and thinner slice thickness (2 mm). PKAID was used to reduce image noise in 2 mm images using the 5 mm images as low-noise prior. Noise amplitude, noise power spectra (NPS), modulation transfer function (MTF), and slice sensitivity profiles (SSPs) of images before/after denoising were analyzed. The NPS and MTF analysis showed that PKAID preserved noise texture and resolution of the original thin-slice image, while reducing noise to the level of thick-slice image. The SSP analysis showed that the slice thickness of the original thin-slice image was retained. Patient examples demonstrated that PKAID-processed, thin-slice images better delineated brain structures and key pathologies such as subdural hematoma compared to the clinical 5 mm images, while additionally reducing image noise. To test an alternative PKAID utilization for dose reduction, a head exam with 40% dose reduction was simulated using projection-domain noise insertion. The image of 5 mm slice thickness was then denoised using PKAID. The results showed that the PKAID-processed reduced-dose images maintained similar noise and image quality compared to the full-dose images.
© 2020 Institute of Physics and Engineering in Medicine.

Entities:  

Keywords:  computed tomography; denoising; head CT; noise reduction; slice thickness

Mesh:

Year:  2020        PMID: 33065559      PMCID: PMC8050138          DOI: 10.1088/1361-6560/abc231

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  27 in total

Review 1.  High-resolution CT of the lungs.

Authors:  E A Kazerooni
Journal:  AJR Am J Roentgenol       Date:  2001-09       Impact factor: 3.959

2.  Early prediction of irreversible brain damage after ischemic stroke at CT.

Authors:  R von Kummer; H Bourquain; S Bastianello; L Bozzao; C Manelfe; D Meier; W Hacke
Journal:  Radiology       Date:  2001-04       Impact factor: 11.105

3.  Prior image constrained compressed sensing: implementation and performance evaluation.

Authors:  Pascal Thériault Lauzier; Jie Tang; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

4.  Adaptive nonlocal means filtering based on local noise level for CT denoising.

Authors:  Zhoubo Li; Lifeng Yu; Joshua D Trzasko; David S Lake; Daniel J Blezek; Joel G Fletcher; Cynthia H McCollough; Armando Manduca
Journal:  Med Phys       Date:  2014-01       Impact factor: 4.071

5.  Quantitative comparison of noise texture across CT scanners from different manufacturers.

Authors:  Justin B Solomon; Olav Christianson; Ehsan Samei
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.071

6.  Development and validation of a practical lower-dose-simulation tool for optimizing computed tomography scan protocols.

Authors:  Lifeng Yu; Maria Shiung; Dayna Jondal; Cynthia H McCollough
Journal:  J Comput Assist Tomogr       Date:  2012 Jul-Aug       Impact factor: 1.826

7.  Methods for clinical evaluation of noise reduction techniques in abdominopelvic CT.

Authors:  Eric C Ehman; Lifeng Yu; Armando Manduca; Amy K Hara; Maria M Shiung; Dayna Jondal; David S Lake; Robert G Paden; Daniel J Blezek; Michael R Bruesewitz; Cynthia H McCollough; David M Hough; Joel G Fletcher
Journal:  Radiographics       Date:  2014 Jul-Aug       Impact factor: 5.333

8.  Spectral prior image constrained compressed sensing (spectral PICCS) for photon-counting computed tomography.

Authors:  Zhicong Yu; Shuai Leng; Zhoubo Li; Cynthia H McCollough
Journal:  Phys Med Biol       Date:  2016-08-23       Impact factor: 3.609

9.  Thin-section CT of the secondary pulmonary lobule: anatomy and the image--the 2004 Fleischner lecture.

Authors:  W Richard Webb
Journal:  Radiology       Date:  2006-03-16       Impact factor: 11.105

Review 10.  High-resolution computed tomography for clinical imaging of bone microarchitecture.

Authors:  Andrew J Burghardt; Thomas M Link; Sharmila Majumdar
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

View more
  3 in total

1.  Quantification of Coronary Calcification using High-Resolution Photon-Counting-Detector CT and an Image Domain Denoising Algorithm.

Authors:  Patrick VanMeter; Jeffrey Marsh; Kishore Rajendran; Shuai Leng; Cynthia McCollough
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2022-04-04

2.  Diagnostic usefulness of cone-beam computed tomography versus multi-detector computed tomography for sinonasal structure evaluation.

Authors:  Miran Han; Hyun Jun Kim; Jin Wook Choi; Do-Yang Park; Jang Gyu Han
Journal:  Laryngoscope Investig Otolaryngol       Date:  2022-03-30

3.  Diagnostic Accuracy and Failure Mode Analysis of a Deep Learning Algorithm for the Detection of Intracranial Hemorrhage.

Authors:  Andrew F Voter; Ece Meram; John W Garrett; John-Paul J Yu
Journal:  J Am Coll Radiol       Date:  2021-04-03       Impact factor: 6.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.