Literature DB >> 33048951

The development of an alternative growth chart for estimated fetal weight in the absence of ultrasound: Application in Indonesia.

Dewi Anggraini1, Mali Abdollahian2, Kaye Marion2.   

Abstract

A fetal growth chart is a vital tool for assessing fetal risk during pregnancy. Since fetal weight cannot be directly measured, its reliable estimation at different stages of pregnancy has become an essential issue in obstetrics and gynecology and one of the critical elements in developing a fetal growth chart for estimated fetal weight. In Indonesia, however, a reliable model and data for fetal weight estimation remain challenging, and this causes the absence of a standard fetal growth chart in antenatal care practices. This study has reviewed and evaluated the efficacy of the prediction models used to develop the most prominent growth charts for estimated fetal weight. The study also has discussed the potential challenges when such surveillance tools are utilized in low resource settings. The study, then, has proposed an alternative model based only on maternal fundal height to estimate fetal weight. Finally, the study has developed an alternative growth chart and assessed its capability in detecting abnormal patterns of fetal growth during pregnancy. Prospective data from twenty selected primary health centers in South Kalimantan, Indonesia, were used for the proposed model validation, the comparison task, and the alternative growth chart development using both descriptive and inferential statistics. Results show that limited access to individual fetal biometric characteristics and low-quality data on personal maternal and neonatal characteristics make the existing fetal growth charts less applicable in the local setting. The proposed model based only on maternal fundal height has a comparable ability in predicting fetal weight with less error than the existing models. The results have shown that the developed chart based on the proposed model can effectively detect signs of abnormality, between 20 and 41 weeks, among low birth weight babies in the absence of ultrasound. Consequently, the developed chart would improve the quality of fetal risk assessment during pregnancy and reduce the risk of adverse neonatal outcomes.

Entities:  

Mesh:

Year:  2020        PMID: 33048951      PMCID: PMC7553358          DOI: 10.1371/journal.pone.0240436

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


Introduction

Fetal growth is one of the critical indicators for assessing fetal risk during pregnancy. The assessment of fetal growth has been well documented as one of the objectives of antenatal care (ANC) to reduce the risk of neonatal mortality and morbidity [1-3]. Monitoring the intrauterine development of the fetus at different stages of pregnancy, even at earlier gestational ages (GAs), is vital for early detection of growth abnormalities [4]. In this way, delays in making informed referrals, decisions, and interventions can be minimized to ensure safe delivery and a positive pregnancy outcome, particularly crucial for those who are living in rural areas or settings with limited health resources. Birth weight is closely associated with fetal growth [5]. The measurement of fetal weight during pregnancy is used to estimate the expected (normal) birth weight [6]. Since fetal weight cannot be directly measured, its reliable estimation at different stages of pregnancy has become one of the important issues in obstetrics and gynecology, and one of the key elements in developing a fetal growth chart for the estimated fetal weight (EFW). The provision of a fetal growth chart for EFW has been identified as one of the fundamental preventive actions to promote healthy human development and to prevent the risk of common non-communicable diseases in later life [5, 7]. The impact of utilizing the growth chart in clinical practice has been investigated [2, 4, 8–10]. The results show a significant improvement in the detection of abnormal growth and a remarkable reduction in unnecessary referrals. Access to routine data collection of EFW at a given GA is required to develop an evidence-based fetal growth chart. In Indonesia, however, such data collection remains challenging and is one of the reasons for the absence of a standard fetal growth chart [11-15]. There is no fetal growth chart for EFW available in the current ANC practice of Indonesian primary health care centers. Its absence is particularly noticeable in the maternal and child health (MCH) booklet (Buku KIA) [16], which is nationally recognized as one of the vital profile monitoring records during pregnancy. This study aims to fill the gap by, first, reviewing and evaluating the efficacy of the prediction models used to develop the most prominent growth charts for EFW. Then, discussing the potential challenges when such surveillance tools are utilized in low resource settings, proposing an alternative growth chart for EFW in the absence of ultrasound, and analyzing the capability of the proposed chart in detecting abnormal patterns of fetal growth during pregnancy.

Methods

Review of existing fetal growth charts for estimated fetal weight and the applicability in low resource settings

A purposive literature review was performed for searching original research articles on the most prominent growth charts for EFW. The selection criteria for the research articles used in this study were based on the sizes of the study population, and the ways fetal growth charts were developed, including both customized and standard approaches. The review and evaluation were explicitly focused on the statistical models used to predict fetal weight and the potential challenges when the charts are utilized in Indonesian health care centers where advanced health equipment and facilities are not always available, or indeed necessary. From the chosen literature, the significant characteristics for each model were identified and investigated whether measurements of these characteristics might be available in the rural settings of Indonesia.

Local evaluation of ultrasound-based prediction models used in the development of existing growth charts for estimated fetal weight and the comparison with the proposed clinical model

A prospective cohort study, between June 1, 2016, and June 30, 2017, was carried out in South Kalimantan, Indonesia. The detailed procedures have been provided in previous publications [12, 15]. The prospective data, both clinical and ultrasound information, were used to validate the existing ultrasonic-based and proposed clinical-based models for estimating fetal weight. The data were obtained from one of the twenty selected primary health care centers that have access to both ultrasound measurement of fetal biometric characteristics and clinical assessment of fundal height (FH) at a given GA. All measurements (from the beginning of pregnancy to delivery) were performed by the dedicated midwife who runs the center. This midwife has had both ultrasound and scientific and technical training [12, 15]. The selected midwife has experienced and been involved in both the provision and delivery of ANC services for ≥ five years (actually 22 years). During the period of study, 30 pregnant women regularly attended ANC and gave birth to the selected center. One (3%) pregnant woman was excluded from the analysis due to low birth weight (LBW) newborn (< 2500 g). Ten women (33%) were excluded from the validation analysis due to unmet inclusion criteria S1 Fig. A comparison study was carried out between the existing and the proposed models using the de-identified prospective data. The existing models were developed based on data recorded within one week of delivery [17, 18] and within 14 days of the last ultrasound scan [19] while the proposed model: was developed based on FH measurement recorded between 35 and 41 weeks (before delivery) and actual birth weight. The model in Eq (1) was the improvement of the clinical model published in Anggraini, et al. [6], which was developed using recorded estimated weight based on the existing Johnson-Toshach formula [20]. Several accuracy measures used in this study, such as mean prediction error (ME), mean percentage prediction error (MPE), mean absolute percentage prediction error (MAPE), and median absolute percentage prediction error (MEDAPE). The number of estimates within 10% and 20% of ABWs (%) is also used to measure the prediction accuracy [6]. In this study, however, a two-sample T-test and a two-sample F-test were added to investigate if there is a significant difference in mean and variance of prediction errors between the existing and proposed models. The prediction accuracy of the existing and proposed models was assessed using the prospective data of 19 pregnant women recorded at different stages of pregnancy: between 16 and 38 weeks (during pregnancy) and between 33 and 40 weeks (before or at delivery).

The development of an alternative growth chart for estimated fetal weight in the absence of ultrasound

This study used information from 435 participating women enrolled in twenty selected primary health care centers, including the prospective cohort study explained in the previous section. Of these, 33 participating women (7.6%) were excluded from the study due to LBW (n = 16), no gender and birth weight information (n = 1), no measurements taken during pregnancy (n = 2), and no information on GA and FH (FH < 12 cm and FH > 38 cm [1], n = 14). Therefore, a total of 402 participating women provided the basis for the development of a true average growth curve based on a weight prediction model that does not use ultrasound data S2 Fig. In this study, a Bernoulli distribution with the event probability (p) of 70% was used to randomly divide 1,408 FH measurements of 402 pregnant women into two data sets. The first data set consists of 989 EFW measurements of 385 pregnant women (training data). The second data set consists of 419 (30%) EFW measurements of 282 pregnant women (testing data). Since this study aims to develop an alternative fetal growth chart for EFW that does not use an ultrasound-based weight prediction model, the proposed clinical model, based only on FH measurement [Eq (1)], was used to estimate the fetal weight at a given GA. The estimated values of fetal weight were then plotted against GA to develop the optimal model of weight prediction based on GA using the curve fitting option in SPSS 23. The idea of this model development was to create the percentile limits (profile limits) for EFW. Regression analysis using curve estimation was used to develop the relationship between EFW (estimated using the proposed clinical model) and GA. Diagnostic tests of residuals were carried out using the Ryan-Joiner or Shapiro-Wilk analysis to compare the sample distribution to a normal curve [21]. Also, a probability plot and histogram with normal curve fit were created to inspect the distribution of residuals visually. The testing data set was used to validate and assess the efficacy of the proposed fetal weight prediction models based on GA. The residual was calculated based on the difference between the actual birth weight (ABW) and the EFW-GA. Multiple comparisons were then carried out between the proposed EFW-GA model and two existing ultrasound-based EFW-GA models [22, 23] to select the most effective model in predicting EFW based on GA. The comparisons were presented in two periods: during pregnancy (13–42 weeks) and before or at delivery (32–42 weeks). This study used the research procedures proposed by Mikolajczyk, et al. [24] to develop an alternative fetal growth chart for EFW. This existing method has been recommended by Gardosi [25] to allow different countries (where reliable population data are not available) to use their own population information to create the references rather than using reference curves based on diverse populations. However, the existing method adapted an ultrasound-based formula proposed by Hadlock, et al. [22] to predict EFW based on GA and create the profile limits for EFW. In this research, the proposed clinical quadratic EFW-GA model: was used to develop the chart. The actual values of birth weight and the predicted values of fetal weight at term pregnancy (between 37 and 41 weeks) (using the value of the 50th percentile weight for GA) were first compared. Then, the proposed alternative fetal growth chart for EFW was implemented among 282 normal newborns (testing data) and 16 LBW newborns identified among 435 singleton live newborns in the prospective study S2 Fig. The capability of the proposed chart in detecting normal and unusual patterns of fetal growth was analyzed by calculating the number of cases and its percentage that falls below the lower specification limit (LSL), i.e., the 10th percentile, between the 10th and 90th percentiles and above the upper specification limit (USL), i.e., the 90th percentile [9].

Ethics approval and consent to participate

This research was conducted using retrospective (past and current) and prospective (longitudinal) data collected from Indonesia. Since the study dealt with personal data, two main ethics clearances were obtained: The Medical Research Ethics Committee, Medical Faculty, University of Lambung Mangkurat, Banjarmasin, South Kalimantan, Indonesia, on March 10, 2016, with registration number 018/KEPK-FK UNLAM/EC/III/2016. Based on the letter-number 019/KEPK-FK UNLAM/EC/III/2016, the validity period of the ethical clearance is from March 10, 2016, until March 2, 2019, or during the time that the research takes place. Permission to access de-identified secondary data in the pregnancy register available at the selected primary health care centers was also granted under this ethics approval. The Science, Engineering, and Health College Human Ethics Advisory Network, RMIT University, Melbourne, Australia, on March 16, 2016, with registration number ASEHAPP 19-16/RM No: 19974. Research permissions were also obtained from the Indonesian national, provincial, and local governments and the provincial health department. Information about the confidential nature of the project and consent forms (written in Bahasa Indonesia and English) for recruitment to the study was given to the selected midwives, who all agreed to participate. These forms were also provided for the pregnant women who participated in the prospective research through the representative midwives. All research participants have also signed and returned the consent forms to the principal researcher.

Results

Review of existing growth charts for estimated fetal weight and evaluation of their applicability in low resource settings

Five original research articles of the most prominent studies on fetal growth charts for EFW were selected: customized fetal growth chart studies (2 articles) and standard fetal growth chart studies (3 articles). The review and evaluation of these studies were summarized and provided in the S1 Table. The first two fetal growth charts for EFW, proposed by Gardosi et al. [26, 27], were developed by considering individual characteristics that significantly influence fetal growth. These widely used charts are referred to as customized fetal growth charts. Both charts were derived from a retrospective study among the British population. Access to ultrasound measurements of fetal biometric characteristics and the minimum database of maternal and fetal characteristics that have a potential impact on fetal growth was required to develop the charts. Also, information on maternal weight at the first visit, height, parity, ethnicity, and gender of fetus/neonate (if known) was needed. These characteristics were used to adjust the range of EFW for an individual pregnant woman. The remaining selected fetal growth charts for EFW were derived from either retrospective or prospective studies across countries with homogenous or heterogeneous populations but healthy, well-nourished, and of low risk of adverse pregnancy outcomes at both population and individual levels. Unlike customized fetal growth charts, these charts were developed without considering individual variability. These charts are referred to as standard fetal growth charts. The first standard growth chart, proposed by Mikolajczyk, et al. [24], is referred to as a global (generic) reference for fetal weight and birth weight percentiles because it combines fetal weight estimation with the notion of proportionality, as proposed by Gardosi, et al. [26]. The profile limits for EFW were developed based on the regression analysis between EFW and GA using Hadlock et al.'s [22] model. The second standard growth chart, proposed by the Intergrowth 21st project [19], was best developed using the fetal weight estimation based on fetal abdominal circumference (AC) and fetal head circumference (HC) measured between 0 and 14 days before delivery. The profile limits for EFW were developed using the Generalized Additive Models for Location, Scale, and Shape (GAMLSS) framework. The last standard growth chart, put forward by the World Health Organization (WHO) [5], was developed using the fetal weight estimation model proposed by Hadlock et al. [22] to create the profile limits for monitoring the change of EFW in terms of GA. However, the selected formula for EFW was based on Hadlock, et al.'s [28] that combines three (instead of four) fetal characteristics [HC, AC, and femur length (FL)] measured by ultrasound within 3–7 days of delivery.

Local evaluation of prediction models used in the development of existing growth charts for estimated fetal weight and the comparison with the proposed model

General information on the study population

Descriptive statistics of the study population (n = 19) are presented in the S2 Table. All pregnant women included in this study followed the minimum recommendation of ANC visits (8 visits). Overall, the pregnant women were between 23 and 32 years old (73.7%), well-nourished with middle-upper arm circumference (MUAC) ≥ 23.5 cm (84.2%), multiparous (68.4%) and had normal body mass index (BMI) at the first visit of ANC (between 18.5 and 24.9 kg/m2) (73.7%). Of these 19 women, 16 (84.2%) delivered the baby through spontaneous (normal) mode, between 37 and 44 weeks, and 15 (79%) were assisted by midwives.

Local validation: Using Indonesian ANC data recorded between 16 and 38 weeks (during pregnancy) and between 33 and 40 weeks (before or at delivery)

The prediction accuracy of the existing and proposed models was assessed using the prospective data of 19 pregnant women recorded at different stages of pregnancy: between 16 and 38 weeks and between 33 and 40 weeks. The results are presented in Tables 1 and 2, respectively.
Table 1

Accuracy of the existing and proposed models (16–38 weeks).

Number of pregnant women = 19 (53 observations)
Prediction error (ABW–EFWp)Mean (ME) (g)Mean percentage (MPE) (%)Mean absolute percentage (MAPE) (%)Median percentage (MEDPE) (%)Median absolute percentage (MEDAPE) (%)Number of estimates within 10% of ABWs (%)Number of estimates within 20% of ABWs (%)
Proposed clinical model
Dewi, Mali, and Kaye (2019): FH1,163.3636.1737.4634.7834.78423
Existing ultrasound models
Campbell and Wilkin (1975): AC1,735.9354.5055.4755.1255.12411
Hadlock (1985) I: AC and FL1,861.8658.6958.6959.9259.9268
Hadlock (1985) II: AC, BPD, and FL1,849.2058.3058.3660.5460.5468
Hadlock (1985) III: AC, HC, and FL1,890.6559.6559.6660.7760.7746
Hadlock (1985) IV: AC, BPD, HC, and FL1,875.1359.1559.2160.8760.8746
Stirnemann (2017): HC and AC1,888.0959.4959.5861.9661.9626
Table 2

Accuracy of the existing and proposed models (33–40 weeks).

Number of pregnant women = 19 (19 observations)
Prediction error (ABW–EFWp)Mean (ME) (g)Mean percentage (MPE) (%)Mean absolute percentage (MAPE) (%)Median percentage (MEDPE) (%)Median absolute percentage (MEDAPE) (%)Number of estimates within 10% of ABWs (%)Number of estimates within 20% of ABWs (%)
Proposed clinical model
Dewi, Mali, and Kaye (2019): FH235.097.0811.4410.5211.094284
Existing ultrasound models
Campbell and Wilkin (1975): AC272.188.4611.6911.6112.034289
Hadlock (1985) I: AC and FL269.768.2815.2412.3415.062684
Hadlock (1985) II: AC, BPD, and FL247.377.5814.8611.0012.452679
Hadlock (1985) III: AC, HC, and FL338.4510.5015.3613.5914.722684
Hadlock (1985) IV: AC, BPD, HC, and FL299.079.2415.1212.9813.072679
Stirnemann (2017): HC and AC503.5816.0417.6118.5518.552158
Tables 1 and 2 show the accuracy comparison between the existing and proposed models. The tables have several measures of prediction errors, such as the mean prediction errors (MEs), the mean percentage errors (MPEs), the mean absolute percentage errors (MAPEs), the median percentage errors (MEDPE), and the median absolute percentage errors (MEDAPEs). It can be seen from the tables that the proposed model [Equation (1)] produced smaller errors in predicting actual birth weight (ABW) than the existing models between 16 and 38 weeks and between 33 and 40 weeks. Tables 1 and 2 also show a smaller number of predictions falling within 10% and 20% of ABWs for all models during pregnancy (16–38 weeks). However, the proposed model is significantly comparable (84%) to the Hadlock, et al. 's [18] models I and III in predicting fetal weight. The proposed model is even better than the Hadlock models II and IV (79%) and the Stirnemann et al. 's [19] (58%) when the estimation of fetal weight was made before or at delivery (between 33 and 40 weeks) with the proportion of predicted birth weights falling within 20% of ABWs. Although Campbell and Wilkin's [17] model was slightly more capable (89%), it has somewhat higher prediction errors compared to the proposed model. The visual comparison of the MEDAPEs can be seen in Figs 1 and 2.
Fig 1

MEDAPEs of the proposed and existing models (16–38 weeks).

Fig 2

MEDAPEs of the proposed and existing models (33–40 weeks).

From Figs 1 and 2, it can be concluded that the proposed model is significantly more capable (less error) than the existing models in predicting fetal weight during pregnancy, even at earlier GAs. It also can be seen that the prediction errors are less pronounced when the pregnancy reaches advanced GAs. The results show that, between 16 and 38 weeks, there is a significant difference in variances and means of prediction errors between the existing and proposed models during pregnancy (p-value < 0.05), except for the variation between the proposed model and Stirnemann et al. 's [19] model (p-value = 0.128) S3 and S4 Tables. There is no significant difference in variances and means of prediction errors, between 33 and 40 weeks, between the existing and proposed models (p-value > 0.05), except for the mean between the proposed model and Stirnemann et al. 's [19] model (p-value = 0.032).

Local evaluation: Assessment of two prominent existing growth charts (the Intergrowth 21st Project and WHO) for estimated fetal weight

The existing fetal growth charts (the Intergrowth 21st project and the WHO) were applied to the prospective data (19 pregnant women with 53 fetal measurements by ultrasound). The results are shown in Figs 3 and 4, with the red line being the 10th percentile, green the 50th, and orange the 90th.
Fig 3

Intergrowth 21st Project fetal growth chart applied to an Indonesian population.

Fig 4

WHO fetal growth chart applied to an Indonesian population.

It can be seen from Figs 3 and 4 that both charts are comparable in fitting the Indonesian data when fetal biometric measurements using ultrasound are available. The WHO chart (Fig 4) fits the local population more effectively than the one proposed by the Intergrowth 21st Project (Fig 3). This can be seen from the distribution of raw observations falling within the 10th, 50th, and 90th percentiles.

Description of the study population

All 435 pregnant women included in this study followed the minimum recommendation of ANC visits (average of 6 visits) with a range between 1 and 14 visits, and only clinical ANC data were used. Overall, the pregnant women were between 23 and 32 years old (61.4%), well-nourished (37.5%) with MUAC ≥ 23.5 cm, multiparous (72.0%), and had normal BMI at the first visit of ANC (between 18.5 and 24.9 kg/m2) (71.3%). Of these 435 women, 391 (89.9%) delivered the baby at term pregnancy, 400 (92.0%) delivered the baby with spontaneous normal mode, 34 (7.8%) delivered preterm (< 37 completed weeks of gestation), 227 (52.2%) delivered male newborns, 200 (46.0%) delivered female newborns, and 356 (81.8%) were assisted by midwives S5 Table.

Efficacy assessment and comparison between the existing ultrasound-based and proposed clinical-based weight prediction models based on gestational age

The quadratic model [Eq(2)] is the best fit clinical model (it has the highest values of R = 0.851). The R2-adjusted (72.4%) shows a significant correlation between EFW and GA. This model also has the least standard error of prediction (309.0 g) S6 Table. Fig 5 shows a scatter plot between EFW (Y) and GA (X) for the best fit quadratic model together with its 95% confidence intervals.
Fig 5

Scatter plot for the proposed quadratic model.

Diagnostic tests of residuals were carried out, and the results are provided in the S7 Table. Based on the Ryan-Joiner or Shapiro Wilk test, it was concluded that the residuals of all the proposed EFW-GA models were roughly symmetric, particularly for the linear model (p-value = 0.025 > 1%). The prediction accuracy between the proposed clinical-based EFW-GA model and the existing ultrasound-based EFW-GA models proposed by Hadlock et al. [22] and Sotiriadis, et al. [23] was also evaluated using the testing dataset. The results are presented in two periods: during pregnancy (13–36 weeks) (Table 3 and Fig 6) and before or at delivery (32–42 weeks) (Table 4 and Fig 7).
Table 3

Accuracy of the proposed and existing EFW-GA models (13–36 weeks).

Number of pregnant women = 234 with 309 FH observations
Prediction error (ABW–EFW-GA)Mean (ME) (g)Mean percentage (MPE) (%)Mean absolute percentage (MAPE) (%)Median percentage (MEDPE) (%)Median absolute percentage (MEDAPE) (%)Number of estimates within 10% of ABWs (%)Number of estimates within 20% of ABWs (%)
Proposed models
Quadratic731.7222.5823.6221.9321.9320.0644.34
Existing models
Hadlock (1991)1635.9351.9252.3355.4555.457.1215.86
Sotiriadis (2018)1684.4353.5053.6856.1356.134.8513.92
Fig 6

MEDAPEs of the proposed and existing EFW-GA models (13–36 weeks).

Table 4

Accuracy of the proposed and existing EFW-GA models (32–42 weeks).

Number of pregnant women = 102 with 110 FH observations
Prediction error (ABW–EFW-GA)Mean (ME) (g)Mean percentage (MPE) (%)Mean absolute percentage (MAPE) (%)Median percentage (MEDPE) (%)Median absolute percentage (MEDAPE) (%)Number of estimates within 10% of ABWs (%)Number of estimates within 20% of ABWs (%)
Proposed models
Quadratic154.423.788.864.078.4961.8293.64
Existing models
Hadlock (1991)-130.83-5.0711.92-6.4510.7947.2782.73
Sotiriadis (2018)161.474.039.633.967.9059.0992.73
Fig 7

MEDAPEs of the proposed and existing EFW-GA models (32–42 weeks).

The prediction ability of the proposed clinical-based EFW-GA model and the two existing ultrasound-based EFW-GA models show that the MEs recorded for the proposed model is significantly smaller [731.72 g (between 13 and 36 weeks) and 154.42 g (between 32 and 42 weeks)] than those recorded for the existing models. Similarly, the MPEs, MAPEs, and MEDAPEs recorded for the proposed model are significantly smaller [22.58%, 23.62%, and 21.93%, respectively (between 13 and 36 weeks) and 3.78%, 8.86%, and 8.49%, respectively (between 32 and 42 weeks)] than those recorded for the existing models [> 50%, respectively (between 13 and 36 weeks) and -5.07–4.03%, 9.63–11.92%, and 7.9–10.79%, respectively (between 32 and 42 weeks)]. Tables 3 and 4 summarize that between 13 and 36 weeks, the proposed model produced more predicted values that fall within the 10% and 20% of ABWs (20.1% and 44.3%, respectively) compared with the Hadlock model (7.1% and 15.9%, respectively) and the Sotiriadis model (4.9% and 13.9%, respectively). The proposed model was also produced more predicted values that fall within 10% and 20% of ABWs (61.8% and 93.6%, respectively) compared with the Hadlock model (47.3% and 82.7%, respectively) and the Sotiriadis model (59.1% and 92.7%, respectively) when the estimates were made before or at delivery (32–42 weeks). The visualization of these multiple comparisons can be seen in Figs 6 and 7. The results also show that, between 32 and 42 weeks, there is a significant difference in variances and means of prediction errors between the proposed model and the existing ultrasound models (p-value < 0.05) S8 Table. However, there is no significant difference in the means of prediction errors within the existing models.

Construction of growth charts for estimated fetal weight based on the proposed EFW-GA quadratic model

Using the proposed EFW-GA quadratic model based on modified methods of Mikolajczyk et al. [24], the predicted values for specific fetal weight percentiles based on non-ultrasound measurements are listed in Table 5 for each GA. The table shows the percentiles (g) of EFW for an Indonesian population in South Kalimantan province with a mean birth weight at 40 weeks of gestation of 3178.4 g.
Table 5

Estimated fetal weights for an Indonesian population.

Gestational age (weeks)Percentiles of estimated fetal weight (g)
1st3rd5th10th25th50th (mean)75th90th95th97th99th
2012711346138614481551166617811884194619862062
2113431423146615311640176218831992205721002180
2214151499154416121727185519832097216622112295
2314841573161916921812194620802201227323202408
2415521645169417691895203521752301237724262518
2516191715176618451976212222682400247925302626
2616831784183719192055220723592496257826312731
2717471851190619912133229024482590267527302834
2818081916197320612208237125342681276928262934
2918681980203921292281245026182770286129203031
3019272042210221962353252627002857295130113126
3119842102216522612422260127802941303831003218
3220392160222523242490267428583023312231873308
3320932217228323852555274429333103320432713395
3421452273234024452619281230063180328433523480
3521952326239525022680287830773255336234313562
3622442378244925582740294331453327343635073641
3722912428250026122798300532113398350935813718
3823372477255026642854306532763465357936533792
3923812523259827142908312333373531364737223864
4024242568264527632960317833973594371237883933
4124652612269028093010323234553655377538523999
Fig 8 demonstrates the distribution of actual (raw) observations of predicted values based on the EFW-FH model (using testing data, n = 282 with 419 observations) superimposed on the EFW curve developed based on the proposed quadratic EFW-GA model together with the 95% confidence interval. The distribution of the actual observations shown in Fig 8 was then superimposed on the existing profile limits proposed by Mikolajczyk, et al. [24], the Intergrowth 21st project reference (International standard) [19] and the WHO [5]. The result is shown in Fig 9.
Fig 8

Proposed fetal weight chart with test data superimposed.

Key: = 10th percentile, = 50th percentile, = 90th percentile, = 95% confidence intervals.

Fig 9

Fit of proposed weight chart compared with existing references.

Key: as for Fig 8 with profile limits added from -------- = global reference [24] — — = Intergrowth 21st Project reference (International standard) [19] – – – – = WHO [5].

Proposed fetal weight chart with test data superimposed.

Key: = 10th percentile, = 50th percentile, = 90th percentile, = 95% confidence intervals.

Fit of proposed weight chart compared with existing references.

Key: as for Fig 8 with profile limits added from -------- = global reference [24] — — = Intergrowth 21st Project reference (International standard) [19] – – – – = WHO [5]. It can be seen from Fig 9 that the existing fetal growth charts for EFW do not fit well to the local population because they underestimate. The patterns of fetal growth measured by clinical measurements are different to the ones measured by ultrasound. Furthermore, fetal birth weight at term pregnancy, between 37 and 41 weeks, was compared using the 50th percentile predicted values of fetal weight from the developed quadratic model and the ABW of the study population. These results were also compared with the predicted values of fetal weight, and the observed values of birth weight derived from the existing models [22, 23] and references [5, 19]. This comparison is presented in Table 6.
Table 6

Fetal birth weight at term pregnancy (37–41 weeks).

Gestational age (week)Weights (g)
Present study (predicted values*)Present study (observed values^)Hadlock (1991) (predicted values*)Hadlock (1991) (observed values^)Sotiriadis (2018) (predicted values*)Stirnemann (2017) (predicted values*)Kiserud (2017) (predicted values*)
3730053027 (10)3028NA276928062966
3830653127 (9)32363234299230063186
3931233142 (11)34353469321331863403
4031783178 (10)36193598342633383617
41NA3112 (12)NA3686NANANA

Note:

Numbers in parentheses are standard deviations expressed as a percentage of the actual mean birth weight

NA = No data or insufficient data at these time points

* The 50th percentile weight for GA based on the model

^ The mean of actual birth weights

Note: Numbers in parentheses are standard deviations expressed as a percentage of the actual mean birth weight NA = No data or insufficient data at these time points * The 50th percentile weight for GA based on the model ^ The mean of actual birth weights It can be seen from Table 6 that generally the mean of predicted fetal weights [based on the proposed model, Equation (2)] in the Indonesian population was lower than those predicted based on the existing models and references, i.e., those developed based on ultrasound measurements of fetal biometrics. At 38 weeks, the expected value was comparable with the one derived from the existing model [23] and the existing reference from the Intergrowth 21st Project [19]. Meanwhile, the mean of actual birth weights in the study population was also lower than the one observed in the existing model [22]. Fig 10 represents the distribution of actual (raw) data of predicted values for the 16 LBW newborns among the 435 singleton live newborns in the prospective data, between 20 and 40 weeks, using the developed fetal growth chart.
Fig 10

Proposed fetal weight chart (20–40 weeks) used with data relating to 16 LBW babies.

The capability of the developed clinical-based fetal growth chart to detect abnormal patterns among 282 normal (Fig 8) and 16 LBW newborns (Fig 10) was assessed by calculating the percentage of cases falling below the LSL (the 10th percentile), within the 10th and the 90th percentiles and above the USL (the 90th percentile). The results are shown in Table 7.
Table 7

Signals of fetal growth abnormality.

Raw data (g)CaseGestational age (weeks)MeasurementNWithin the optimal fetal growth limitsOutside the optimal fetal growth limits
Between the 10th and 90th percentilesBelow the 10th percentileBelow the 50th percentileAbove the 90th percentile
EFW Model 5 (The optimal clinical-based prediction model based on FH)Normal newbornsBetween 13 and 42 weeksIndividual pregnant women282186 (66.0%)59 (20.9%)153 (54.3%)37 (13.1%)
Repeated observations419302 (72.1%)70 (16.7%)228 (54.4%)47 (11.2%)
LBW newbornsBetween 13 and 39 weeksIndividual pregnant women166 (37.5%)7 (43.8%)11 (68.8%)3 (18.8%)
Repeated observations4018 (45.0%)18 (45.0%)29 (72.5%)4 (10.0%)
Based on the data in Table 7, the developed fetal growth chart was able to detect 43.8–68.8% of the abnormal patterns of EFW during pregnancy among pregnant women who delivered LBW babies. When fetuses were delivered with normal weight, the risk of having such unusual growth patterns was smaller (20.9–54.3%). It shows that for 16 LBW babies, 7 (43.8%) had at least one EFW reading falling below the proposed 10th percentile and 11 (68.8%) at least one EFW reading below the 50th percentile.

Discussion

Fetal growth charts have not been introduced in the Indonesian first level of health care systems. The growth charts are also not included in the current MCH booklet (Buku KIA) that is used to monitor individual mothers, fetuses, and newborns during ANC and postnatal care [12, 15, 16]. This study, therefore, set out with the aim of filling this gap, first by reviewing the existing studies on fetal growth charts, particularly for EFW. Potential challenges when implementing such surveillance tools in Indonesian primary health care centers were also statistically reviewed. This local review is necessary to ensure the fitness and feasibility of the charts to the Indonesian population before their implementation [5, 8]. Based on the literature review, the selected studies on fetal growth charts have used previously published ultrasound-based statistical models to estimate fetal weight. However, in the majority of limited resource settings, the provision of ultrasound machines and skilled personnel is logistically not always available [1, 29]. It has already been noted that the ultrasound method to estimate the fetal weight is not universally accessible in the current practice of ANC across Indonesian primary health care centers [12, 15]. This hinders fetal weight estimation using the ultrasound prediction models that are commonly used in the existing fetal growth chart studies. A fetal weight prediction model based on the clinical measurement of FH has been proposed in the previous study [30]. This model was used in the development of one of the existing customized fetal growth charts as an alternative in the absence of ultrasound facilities. The model was constructed based on a linear relationship between EFW and FH, which was measured simultaneously during the third trimester of pregnancy. However, the EFW was derived from the extrapolation technique of Campbell and Wilkin [17] and the formulas of Hadlock, et al. [18] and Mongelli, et al. [31]. Therefore the clinical-based prediction model proposed in their study still depends on ultrasound data. A minimum dataset of individual maternal, fetal, and neonatal characteristics is required to utilize the existing customized fetal growth charts. This information is used to derive the regression coefficients for adjusting the term optimal weight [27]. However, access to this information remains challenging in most developing countries, particularly in the majority of Indonesian primary health care centers, due to low quality in the routine collection of ANC data [12, 15]. As already mentioned in our previous publication [15], the average amount of recorded ANC data across primary health care providers in the South Kalimantan province, between 2012 and 2016, was approximately 17.5%. This result is lower than the national reported figure of 42.5% [32]. For this reason, the existing customized fetal growth charts are less applicable in Indonesia. This study has assessed the accuracy of the ultrasound-based prediction models used in the development of the existing fetal growth charts and compared them with the proposed clinical model before implementation in the Indonesian population. Such validation is highly recommended to ensure the fitness and practicability of charts for the local population [5, 8]. Based on the comparison analysis, the proposed model produced fewer prediction errors than the existing models both during pregnancy (between 16 and 38 weeks) and before or at delivery (between 33 and 40 weeks). The recorded MPE was 7.1% in those born within an average of 14 days (2 weeks between the last scan and birth) (n = 19). This error is smaller than in the previous research (-10.7%) on babies born precisely 14 days after the last scan (n = 196). In the previous publication [6], it has been shown that a weight prediction model based on FH only produced fewer errors compared with the existing clinical and ultrasound models. Therefore, the proposed model, as the improvement of the previously published model [6], can be a potential weight prediction model to be used in the development of an alternative fetal growth chart for EFW. This is particularly significant for those who are living in rural areas where ultrasound is not always accessible. Ultrasound measurement, as a complement to the routine measurement of FH, is necessary only if it is considered appropriate. Regular analysis of FH is recommended for low-risk pregnancies to screen the intrauterine development of the fetus [1, 3, 33]. On the other hand, ultrasound measurement of fetal characteristics is recommended only for high-risk pregnancies to monitor the growth of the fetus [1, 3]. Two standard fetal growth charts for EFW, one proposed by the Intergrowth 21st Project and one by WHO, were evaluated for their fit to the Indonesian population [5, 19]. Based on the analysis, both charts could potentially be implemented in Indonesian primary health care centers to monitor fetal growth provided that information on fetal biometric characteristics (required to estimate fetal weight) is available. The former chart uses its own EFW based on AC and HC, while the latter chart uses the EFW model previously published by Hadlock et al. [18], which is based on AC, HC, and FL. However, their practicality remains challenging for Indonesian ANC settings due to the lack of recorded data on fetal biometric characteristics during pregnancy [6, 12, 15]. Therefore, an alternative weight prediction model using clinical measurement (rather than ultrasound measurement) is required to develop a suitable fetal growth chart for EFW. The chart can be easily implemented in the local primary health care centers or other settings with low health resources. The proposed quadratic clinical model was selected as the most suitable formula to be used to develop an alternative fetal growth chart for EFW in settings with limited resources (no ultrasound). The proposed quadratic regression model has produced more effective estimates of fetal weight than the existing ultrasound formulas. Furthermore, the proposed formula for estimating fetal weight is simple and can be used by doctors, midwives, and pregnant women. This would improve the quality of communication, information, and education as part of routine ANC service in low-resource primary health care centers. The quadratic model fitted the local data more efficiently compared to the other estimating models, particularly between 24 and 40 weeks of gestation. This finding seems to be consistent with other research, which found that the quadratic model was the optimal prediction model for fetal weight between the second and third trimesters of pregnancy [22, 23, 34]. Therefore, in this study, the quadratic model has been used to develop an alternative fetal growth chart. The prediction accuracy of the optimal model, i.e., the quadratic model, has also been assessed using a prospective dataset and compared with the existing regression models based on ultrasound measurements [22, 23]. The MPE for the proposed model was 22.6% in those born between 13 and 36 weeks (prospective; n = 234). This percentage error was lower than the existing ultrasound-based prediction models [22, 23] when implemented on local data (MPEs 51.9–53.5%). Using data recorded between 32 and 42 weeks (before or at delivery), the results showed that the proposed quadratic model produced smaller ME (154.4g), less MPE (3.8%), and less MAPE (8.9%). The MPE steadily tended towards zero as the time interval between the last scan and birth decreased [19]. The MAPE was higher than that reported by Hadlock et al. [22] when they applied their model in their original population (1.1%) but smaller than the one indicated in the existing study when Hadlock et al. 's model was used to the local population (11.9%). The results show that the difference between EFW during pregnancy (between 13 and 36 weeks) and ABW was more significant than when it was measured before delivery (between 32 and 42 weeks). This finding is in agreement with Hadlock's earlier study of fetal growth [22] and also the most recent study reported in the literature [23]. The divergence between predicted and observed term birth weights reported in this study (MPE = 3.8% and MAPE = 8.9%) are higher than those published by Hadlock (MPE = 0.8% and MAPE = 1.1%), while the average variability reported in this study (when expressed as a percentage of the predicted values) is smaller (11%) (Table 5) than in the earlier study (13%) [22]. Also, at earlier GAs, for example, at 27 weeks, the difference between ABWs and EFWs reported in this study was smaller (11%) than that published in Sotiriadis' recent study (14%) [23]. There is no fetal growth chart for EFW available in the current ANC practice of Indonesian primary health care centers. Its absence is particularly noticeable in the MCH booklet (Buku KIA) [16], which is nationally recognized as one of the vital profile monitoring records during pregnancy. One of the reasons for this is the difficulty in collecting the data required to develop a standard fetal growth chart [11, 12, 15]. This study, therefore, set out with the aim of creating a fetal growth chart for use in the primary health care settings in Indonesia. Customized and standard fetal growth charts for EFW have been developed and are highly recommended for general use when local data are not available. The charts can be used to monitor fetal growth, defined as the change in EFW with GA. If access to ultrasound measurement of fetal biometric characteristics is limited, this hinders fetal weight estimation using the existing models. Low-quality data (missing or incomplete records) on the minimum data requirements on individual maternal, fetal, and neonatal characteristics also make the existing customized charts less applicable in the local setting. These have been identified statistically as some of the potential challenges in implementing the existing charts in the Indonesian primary health care centers. The fetal growth charts are developed to monitor the growth patterns at different GAs and ensure that they follow normal predicted values and limits for fetal weight so that the optimal birth weight and a safe pregnancy outcome can be achieved. Since GA is not a significant predictor for birth weight [19], a prediction model of fetal weight is commonly developed based on FH or ultrasonic measurements. This EFW model was then regressed by GA to generate a growth chart for EFW. As a result, most of the existing fetal growth charts for EFW have been developed based on regression models between EFW and GA, i.e., derived based on ultrasound-based prediction models using fetal biometric characteristics [5, 19, 24, 26, 27]. However, the use of ultrasound-based prediction models to estimate fetal weight makes it challenging to implement these existing charts for the Indonesian population due to a lack of access to actual fetal biometric data. This study proposed an alternative fetal growth chart based on the most effective clinical-based EFW-FH model (based on FH measurement) for predicting fetal weight at a given GA. This chart can be easily implemented in settings with limited resources using readily accessible clinical information rather than ultrasound data. A wide range of statistical methods has been implemented to construct GA-related charts for pregnancy dating, fetal size, and fetal weight [35], mainly using a parametric approach from cross-sectional to longitudinal data. The aim of this study, however, is to create a fetal growth chart for use in Indonesia to make up for the absence of fetal growth charts in settings with limited resources. Therefore simpler yet still appropriate techniques would preferably be used to develop this chart. This study, for the first time, has developed an alternative fetal growth chart for EFW based on a weight prediction model that uses easily accessible, statistically significant Indonesian clinical data, the maternal FH. It is essential to highlight the significance of the developed growth chart for risk assessment during ANC to prevent LBW delivery. Using prospective data, it has been shown that the proposed chart can effectively detect signs of abnormality with the risk of LBW delivery between 20 and 41 weeks. The introduction of the chart can assist midwives and other medical practitioners to identify high-risk pregnancies, prevent delays in making decisions, referrals, and interventions, and reduce the number of unnecessary investigations during ANC. The utilization of this chart in primary health care centers, as the first level of healthcare in Indonesia and located near where people live, should be prioritized. The development of the fetal growth chart followed the previously published procedures of Mikolajczyk et al. [24]. Their methods combine the fetal weight estimation with the notion of proportionality, as proposed by Gardosi, et al. [26], and adjust it to the mean birth weight at 40 weeks of gestation for any local population. However, the current methods used one of the ultrasound-based prediction models, the one proposed by Hadlock, et al. [18], which was based on fetal measurements of biparietal diameter (BPD), HC, AC and FL to estimate fetal weight. Then the model was regressed by GA [22] to construct the fetal growth chart. It has also been suggested that the existing reference charts, i.e., those developed based on EFW and GA, should not be applied for monitoring fetuses whose ages (GA) were not verified using ultrasound [22]. Therefore a quadratic model was developed based on regression analysis between EFW (based on FH) and GA, and this was used to create the alternative fetal growth chart. The mean birth weight at 40 weeks in the local population was calculated from 142 pregnant women who delivered live singleton newborns with normal weight. Following the recommendations of Mikolajczyk, et al. [24], the size of this sample population at 40 weeks agrees with the population sample size recommended providing acceptable accuracy, i.e., a minimum of 100 samples per GA, and with the inclusion criteria for reference birth weights of a population. The local SD is smaller (10.1%) than the empirical SD in most countries that participated in 2004–2008 WHO Global Survey on Maternal and Perinatal Health (average 13.2%, i.e., 13.2% of the mean weight at 40 weeks) [24]. The result implies that the local population was more homogeneous in birth weight distribution at 40 weeks than other countries involved in the WHO global survey. Since the aim is to reduce the prevalence of LBW newborns, this study concentrated only on the detection of EFW below the 10th and 50th percentiles. It is important to highlight the significance of the proposed EFW growth chart for risk assessment during ANC to prevent LBW newborns, and to repeat that there is currently no equivalent in use in Indonesia. Evaluation of the data from the 16 women who had LBW babies out of the 435 pregnant women studied shows that the proposed chart can effectively detect signs of abnormality. A predominant strength of this research was its methods and data sources. This research has implemented a prospective study using more reliable information, which is the ideal method to monitor and record changes in the process of pregnancy from the start to delivery. This longitudinal study approach has also been recognized as the most recommended design for studies in fetal growth [36, 37]. This study also encountered limitations associated with the accuracy of the information recorded on the manual pregnancy register or with inaccurate data transferred to the electronic database. This limitation was minimized by monitoring and controlling the process of data transfer to reduce potential error.

Conclusions

The proposed clinical model has a comparable ability in predicting fetal weight with less error than the existing models and is, in fact, even more, effective at earlier GAs than the existing models. Consequently, the proposed model could be an alternative model to estimate fetal weight and develop a suitable fetal growth chart. The presence of this alternative chart would be particularly significant for those who are living in rural areas where ultrasound facilities are not always available. This would improve the quality of fetal risk assessment during pregnancy to detect fetal growth abnormalities and reduce the risk of adverse neonatal outcomes. In conclusion, the outcomes of this research can provide useful administrative and scientific guidelines for the expansion of health services and programs and the effective distribution of limited government resources in rural areas. This includes analysis of where further aid investments are likely to the best impact on reducing neonatal mortality. The outcomes can also effectively aid midwives and other medical practitioners in identifying the key risk factors and types of clinical interventions required before delivery to reduce the mortality rate.

Recruitment of participants.

(PDF) Click here for additional data file.

Recruitment of study participants.

(PDF) Click here for additional data file.

Selected studies on fetal growth charts for estimated fetal weight.

(PDF) Click here for additional data file.

Baseline characteristics and antenatal events.

(PDF) Click here for additional data file.

Two-sample F-test and T-test results (16–38 weeks).

(PDF) Click here for additional data file.

Two-sample F-test and T-test results (33–40 weeks).

(PDF) Click here for additional data file. (PDF) Click here for additional data file.

Regression models between EFW and GA.

(PDF) Click here for additional data file.

Analysis of residuals.

(PDF) Click here for additional data file.

Two-sample F-test and T-test results (32–42 weeks).

(PDF) Click here for additional data file. 20 Jul 2020 PONE-D-19-33469 The development of an alternative growth chart for estimated fetal weight in the absence of ultrasound: application in Indonesia PLOS ONE Dear Dr. Anggraini, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. ============================== ============================== Please submit your revised manuscript by Aug 09 2020 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript: A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'. A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'. An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'. If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: http://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols We look forward to receiving your revised manuscript. Kind regards, Giovanni Delli Carpini Academic Editor PLOS ONE Journal Requirements: When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf 2. Please amend your current ethics statement to address the following concerns: a) Did participants provide their written or verbal informed consent to participate in this study? b) If consent was verbal, please explain i) why written consent was not obtained, ii) how you documented participant consent, and iii) whether the ethics committees/IRB approved this consent procedure. Additional Editor Comments (if provided): Please revise the manuscript according to Author's instructions and Manuscript preparation guidelines. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes Reviewer #2: Yes ********** 2. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: I Don't Know Reviewer #2: Yes ********** 3. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: Yes ********** 4. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes ********** 5. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: No, i don't have any comments for authors. But he did not follow author's instructions and manuscript preparation guidelines. Author needs to follow journal's manuscript preparation guidelines in order to create good manuscript. Reviewer #2: The present study entitled “The development of an alternative growth chart for estimated fetal weight in the absence of ultrasound: application in Indonesia” by Anggraini Dewi at al. showed that the proposed model based on maternal fundal height has a comparable ability in predicting fetal weight with less error than existing model and it would improve the quality of fetal risk assessment during pregnancy and reduce the risk of adverse neonatal outcomes. Despite relevant topic and public health importance of the study, there are many issues related to presentation of results, discussions and conclusions which need to be addressed for strengthening the paper in order to maintain readers’ clarity and interest. Major revisions: • In results, while describing the general characteristics of study population, total number of enrolled women is missing and without this, it is difficult to understand various percentages given in this section. • While describing tables 1 and 2, authors have reported all estimates (ME, MPE, MAPE, PEDPE, etc.) in lines from 285 to 297. This text should be rephrased to simplify the message of both tables. • In Tables 1, all median percentages and median absolute percentages for various models are same, whereas in table 2, both values are different for all models except Stirnemann (2017). These should be rechecked. • The lines 320 and 321 regarding F test should be removed from here as it has already been described in lines 134 – 136 in methods section. • Lines 373 and 374 “However, since ………. Problems.” Should be part of discussion. • Lines 413 and 414 on page 19 regarding F test should be moved to methods. • Lines 418 – 420 can be moved to discussion/conclusion. Similarly, lines 457 – 459 on page 21 “The reason ………….EFW-FH model” should be moved to discussion. • The text “Since the aim ………………percentiles” in lines 501 and 502 should be the part of discussion • The conclusion part should be revised as most of the text given in 1st and 3rd para of conclusions should be part of discussion. Similarly, the strengths and limitations of the study given on pages 32 and 33 under conclusion section should be moved to discussion section. Minor corrections: • The abstract can be presented with standard headings, such as Introduction, methods, results, and Conclusion. • Some language corrections will further improve the quality of paper. ********** 6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #2: No [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. 12 Aug 2020 SUMMARY OF MAIN CHANGES FOR PAPER Paper Title: The development of an alternative growth chart for estimated fetal weight in the absence of ultrasound: Application in Indonesia Manuscript ID: PONE-D-19-33469 Response to reviewers' comments The authors would like to thank the editor and the reviewers for their constructive comments on the paper. Responses to the editor's and reviewers' comments have been provided immediately after the comment. Additional requirements "When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf Response to additional requirements 1: Thank you for the feedback. We have revised the manuscript based on PLOS ONE's style requirements and templates, including file naming. 2. Please amend your current ethics statement to address the following concerns: a) Did participants provide their written or verbal informed consent to participate in this study? b) If consent was verbal, please explain i) why written consent was not obtained, ii) how you documented participant consent, and iii) whether the ethics committees/IRB approved this consent procedure". Response to additional requirements 2: We have amended the ethics statement as suggested and highlighted the changes in lines 190-207 in the revised manuscript. Additional Editor Comments "Please revise the manuscript according to the Author's instructions and Manuscript preparation guidelines." Response to additional Editor Comments: We have revised the manuscript according to the Author's instructions and Manuscript preparation guidelines. Reviewer 1 Comment 1: "No, I don't have any comments for authors. But he did not follow the Author's instructions and manuscript preparation guidelines. The author needs to follow the journal's manuscript preparation guidelines to create a good manuscript". Authors' response to comment 1: Thank you for the suggestion. We have revised the manuscript and followed the Author's instructions and Manuscript preparation guidelines Reviewer 2 Major Revisions Comment 1: "In results, while describing the general characteristics of the study population, the total number of enrolled women is missing, and without this, it is difficult to understand various percentages given in this section." Authors' response to comment 1: Thank you for the constructive feedback. We have put the total number of enrolled women used for: the local evaluation, the validation of the prediction models deployed in the development of existing growth charts for estimated fetal weight, and the comparison with the proposed model. The correction is highlighted on line 250 in the revised manuscript. Comment 2: "While describing tables 1 and 2, authors have reported all estimates (ME, MPE, MAPE, PEDPE, etc.) in lines from 285 to 297. This text should be rephrased to simplify the message of both tables". Authors responses to comments 2: Thank you for the suggestion. We have rephrased the paragraph to simplify the message of Tables 1 and 2. The changes are highlighted in lines 269-274 in the revised manuscript. Comment 3: "In Tables 1, all median percentages and median absolute percentages for various models are the same, whereas, in table 2, both values are different for all models except Stirnemann (2017). These should be rechecked". Authors responses to comments 3: Thank you for the critical feedback. We have rechecked, and all median percentages and median absolute percentages for various models in both Tables 1 and 2 are correct. Comment 4: "The lines 320 and 321 regarding F test should be removed from here as it has already been described in lines 134 – 136 in methods section". Authors responses to comments 4: Thank you for the correction. We have removed the sentence in lines 320-321 regarding the F test in the revised manuscript. Comment 5: "Lines 373 and 374 "However, since ………. Problems." Should be part of the discussion". Authors responses to comments 5: Thank you for the suggestion. We have removed the sentence in the revised manuscript. Comment 6: "Lines 413 and 414 on page 19 regarding F test should be moved to methods". Authors responses to comments 6: Thank you for the constructive feedback. We have moved lines 413 and 414 to the Methods section and highlighted in lines 133-135 in the revised manuscript. Comment 7: "Lines 418 – 420 can be moved to discussion/conclusion. Similarly, lines 457 – 459 on page 21, "The reason ………….EFW-FH model" should be moved to the discussion." Authors responses to comments 7: Thank you for the critical feedback. We have moved lines 418-420 and lines 457-459 to the Discussion section. The changes are highlighted in lines 524-525 and lines 577-579, respectively, in the revised manuscript. Comment 8: "The text "Since the aim ………………percentiles" in lines 501 and 502 should be the part of the discussion". Authors responses to comments 8: Thank you for the constructive feedback. We have moved lines 501-502 to the Discussion section. The changes are highlighted in lines 621-622 in the revised manuscript. Comment 9: "The conclusion part should be revised as most of the text given in the 1st and 3rd para of conclusions should be part of the discussion. Similarly, the strengths and limitations of the study given on pages 32 and 33 under the conclusion section should be moved to the discussion section". Authors responses to comments 9: Thank you for the comment and suggestions. We have moved the 1st and 3rd paragraphs of the conclusion to the Discussion section. The changes are highlighted in lines 564-571 and lines 591-600, respectively in the revised manuscript. We also moved the strengths and limitations of the study to the Discussion section. The changes are also highlighted in lines 627-631 and lines 632-635 in the revised manuscript. Minor Corrections Comment 10: "The abstract can be presented with standard headings, such as Introduction, methods, results, and Conclusion." Authors responses to comments 10: Thank you for the comment. However, the abstract has been presented and written based on the following PLOS ONE's style templates https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf. Comment 11: "Some language corrections will further improve the quality of the paper." Authors responses to comments 11: Thank you for the suggestion. This paper has been proofread and corrected from some language errors. Submitted filename: Response to Reviewers.docx Click here for additional data file. 28 Sep 2020 The development of an alternative growth chart for estimated fetal weight in the absence of ultrasound: application in Indonesia PONE-D-19-33469R1 Dear Dr. Anggraini, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Giovanni Delli Carpini Academic Editor PLOS ONE Additional Editor Comments (optional): Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation. Reviewer #1: All comments have been addressed Reviewer #2: All comments have been addressed ********** 2. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes Reviewer #2: (No Response) ********** 3. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes Reviewer #2: (No Response) ********** 4. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: (No Response) ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: (No Response) ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: (No Response) Reviewer #2: (No Response) ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #2: No 2 Oct 2020 PONE-D-19-33469R1 The development of an alternative growth chart for estimated fetal weight in the absence of ultrasound: Application in Indonesia Dear Dr. Anggraini: I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department. If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org. If we can help with anything else, please email us at plosone@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Dr. Giovanni Delli Carpini Academic Editor PLOS ONE
  30 in total

1.  Ultrasonic measurement of fetal abdomen circumference in the estimation of fetal weight.

Authors:  S Campbell; D Wilkin
Journal:  Br J Obstet Gynaecol       Date:  1975-09

2.  Customised antenatal growth charts.

Authors:  J Gardosi; A Chang; B Kalyan; D Sahota; E M Symonds
Journal:  Lancet       Date:  1992-02-01       Impact factor: 79.321

3.  Surveillance in longitudinal models: detection of intrauterine growth restriction.

Authors:  Max Petzold; Christian Sonesson; Eva Bergman; Helle Kieler
Journal:  Biometrics       Date:  2004-12       Impact factor: 2.571

4.  Divergence of estimated fetal weight and birth weight in singleton fetuses.

Authors:  Alexandros Sotiriadis; Makarios Eleftheriades; Vassileios Papadopoulos; Kosmas Sarafidis; Panagiota Pervanidou; Efstratios Assimakopoulos
Journal:  J Matern Fetal Neonatal Med       Date:  2017-03-08

5.  Fetal femur length: a critical reevaluation of the relationship to menstrual age.

Authors:  A H Warda; R L Deter; I K Rossavik; R J Carpenter; F P Hadlock
Journal:  Obstet Gynecol       Date:  1985-07       Impact factor: 7.661

6.  Gestation-adjusted projection of estimated fetal weight.

Authors:  M Mongelli; J Gardosi
Journal:  Acta Obstet Gynecol Scand       Date:  1996-01       Impact factor: 3.636

7.  Estimation of fetal weight with the use of head, body, and femur measurements--a prospective study.

Authors:  F P Hadlock; R B Harrist; R S Sharman; R L Deter; S K Park
Journal:  Am J Obstet Gynecol       Date:  1985-02-01       Impact factor: 8.661

8.  Early-life prevention of non-communicable diseases.

Authors:  John M Balbus; Robert Barouki; Linda S Birnbaum; Ruth A Etzel; Peter D Gluckman; Philippe Grandjean; Christine Hancock; Mark A Hanson; Jerrold J Heindel; Kate Hoffman; Génon K Jensen; Ann Keeling; Maria Neira; Cristina Rabadán-Diehl; Johanna Ralston; Kwok-Cho Tang
Journal:  Lancet       Date:  2013-01-05       Impact factor: 79.321

9.  INTERGROWTH-21st vs customized birthweight standards for identification of perinatal mortality and morbidity.

Authors:  Ngaire H Anderson; Lynn C Sadler; Christopher J D McKinlay; Lesley M E McCowan
Journal:  Am J Obstet Gynecol       Date:  2015-11-04       Impact factor: 8.661

10.  Foetal weight prediction models at a given gestational age in the absence of ultrasound facilities: application in Indonesia.

Authors:  Dewi Anggraini; Mali Abdollahian; Kaye Marion
Journal:  BMC Pregnancy Childbirth       Date:  2018-11-06       Impact factor: 3.007

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.