Literature DB >> 33037503

Deep learning-based image reconstruction for brain CT: improved image quality compared with adaptive statistical iterative reconstruction-Veo (ASIR-V).

Injoong Kim1, Hyunkoo Kang1, Hyun Jung Yoon1, Bo Mi Chung1, Na-Young Shin2.   

Abstract

PURPOSE: To compare the image quality of brain computed tomography (CT) images reconstructed with deep learning-based image reconstruction (DLIR) and adaptive statistical iterative reconstruction-Veo (ASIR-V).
METHODS: Sixty-two patients underwent routine noncontrast brain CT scans and datasets were reconstructed with 30% ASIR-V and DLIR with three selectable reconstruction strength levels (low, medium, high). Objective parameters including CT attenuation, noise, noise reduction rate, artifact index of the posterior cranial fossa, and contrast-to-noise ratio (CNR) were measured at the levels of the centrum semiovale and basal ganglia. Subjective parameters including gray matter-white matter differentiation, sharpness, and overall diagnostic quality were also assessed and compared with the interobserver agreement.
RESULTS: There was a gradual reduction in the image noise and artifact index of the posterior cranial fossa as the strength levels of DLIR increased (all P < 0.001) compared with that of ASIR-V. CNR in both the centrum semiovale and basal ganglia levels also improved from the low to high strength levels of DLIR compared with that of ASIR-V (all P < 0.001). DLIR images with medium and high strength levels demonstrated the best subjective image quality scores among the reconstruction datasets. There was moderate to good interobserver agreement for the subjective image quality assessments with ASIR-V and DLIR.
CONCLUSION: On routine brain CT scans, optimized protocols with DLIR allowed significant reduction of noise and artifacts with improved subjective image quality compared with ASIR-V.

Entities:  

Keywords:  Adaptive statistical iterative reconstruction-Veo; Brain CT; Deep learning image reconstruction; Image quality

Year:  2020        PMID: 33037503     DOI: 10.1007/s00234-020-02574-x

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  23 in total

1.  Reduced partial volume artifacts using spiral computed tomography and an integrating interpolator.

Authors:  D J Heuscher; M Vembar
Journal:  Med Phys       Date:  1999-02       Impact factor: 4.071

2.  Single- versus multi-detector row CT of the brain: quality assessment.

Authors:  T R Jones; R T Kaplan; B Lane; S W Atlas; G D Rubin
Journal:  Radiology       Date:  2001-06       Impact factor: 11.105

3.  Using the baseline CT scan to select acute stroke patients for IV-IA therapy.

Authors:  M D Hill; A M Demchuk; T A Tomsick; Y Y Palesch; J P Broderick
Journal:  AJNR Am J Neuroradiol       Date:  2006-09       Impact factor: 3.825

Review 4.  Deep learning.

Authors:  Yann LeCun; Yoshua Bengio; Geoffrey Hinton
Journal:  Nature       Date:  2015-05-28       Impact factor: 49.962

5.  State of the Art: Iterative CT Reconstruction Techniques.

Authors:  Lucas L Geyer; U Joseph Schoepf; Felix G Meinel; John W Nance; Gorka Bastarrika; Jonathon A Leipsic; Narinder S Paul; Marco Rengo; Andrea Laghi; Carlo N De Cecco
Journal:  Radiology       Date:  2015-08       Impact factor: 11.105

6.  Improving filtered backprojection reconstruction by data-dependent filtering.

Authors:  Daniel M Pelt; Kees Joost Batenburg
Journal:  IEEE Trans Image Process       Date:  2014-07-22       Impact factor: 10.856

7.  What is the preferred strength setting of the sinogram-affirmed iterative reconstruction algorithm in abdominal CT imaging?

Authors:  Andrew D Hardie; Rachel M Nelson; Robert Egbert; William J Rieter; Sameer V Tipnis
Journal:  Radiol Phys Technol       Date:  2014-08-28

Review 8.  Deep Learning: A Primer for Radiologists.

Authors:  Gabriel Chartrand; Phillip M Cheng; Eugene Vorontsov; Michal Drozdzal; Simon Turcotte; Christopher J Pal; Samuel Kadoury; An Tang
Journal:  Radiographics       Date:  2017 Nov-Dec       Impact factor: 5.333

9.  Pediatric head computed tomography with advanced modeled iterative reconstruction: focus on image quality and reduction of radiation dose.

Authors:  Hyun-Hae Cho; So Mi Lee; Sun Kyoung You
Journal:  Pediatr Radiol       Date:  2019-10-19

10.  Thin-slice brain CT with iterative model reconstruction algorithm for small lacunar lesions detection: Image quality and diagnostic accuracy evaluation.

Authors:  Xiaoyi Liu; Lei Chen; Weiwei Qi; Yan Jiang; Ying Liu; Miao Zhang; Nan Hong
Journal:  Medicine (Baltimore)       Date:  2017-12       Impact factor: 1.817

View more
  6 in total

1.  Deep learning image reconstruction algorithm reduces image noise while alters radiomics features in dual-energy CT in comparison with conventional iterative reconstruction algorithms: a phantom study.

Authors:  Jingyu Zhong; Yihan Xia; Yong Chen; Jianying Li; Wei Lu; Xiaomeng Shi; Jianxing Feng; Fuhua Yan; Weiwu Yao; Huan Zhang
Journal:  Eur Radiol       Date:  2022-10-05       Impact factor: 7.034

2.  Accuracy of two deep learning-based reconstruction methods compared with an adaptive statistical iterative reconstruction method for solid and ground-glass nodule volumetry on low-dose and ultra-low-dose chest computed tomography: A phantom study.

Authors:  Cherry Kim; Thomas Kwack; Wooil Kim; Jaehyung Cha; Zepa Yang; Hwan Seok Yong
Journal:  PLoS One       Date:  2022-06-23       Impact factor: 3.752

3.  Reduced-Dose Deep Learning Reconstruction for Abdominal CT of Liver Metastases.

Authors:  Corey T Jensen; Shiva Gupta; Mohammed M Saleh; Xinming Liu; Vincenzo K Wong; Usama Salem; Wei Qiao; Ehsan Samei; Nicolaus A Wagner-Bartak
Journal:  Radiology       Date:  2022-01-11       Impact factor: 29.146

4.  Deep learning versus iterative image reconstruction algorithm for head CT in trauma.

Authors:  Zlatan Alagic; Jacqueline Diaz Cardenas; Kolbeinn Halldorsson; Vitali Grozman; Stig Wallgren; Chikako Suzuki; Johan Helmenkamp; Seppo K Koskinen
Journal:  Emerg Radiol       Date:  2022-01-05

5.  Impact of deep learning-based image reconstruction on image quality compared with adaptive statistical iterative reconstruction-Veo in renal and adrenal computed tomography.

Authors:  Yifan Bie; Shuo Yang; Xingchao Li; Kun Zhao; Changlei Zhang; Hai Zhong
Journal:  J Xray Sci Technol       Date:  2022       Impact factor: 2.442

6.  Impact of an artificial intelligence deep-learning reconstruction algorithm for CT on image quality and potential dose reduction: A phantom study.

Authors:  Joël Greffier; Salim Si-Mohamed; Julien Frandon; Maeliss Loisy; Fabien de Oliveira; Jean Paul Beregi; Djamel Dabli
Journal:  Med Phys       Date:  2022-06-24       Impact factor: 4.506

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.