Magnetic resonance elastography for estimating in vivo stiffness of the abdominal aorta using cardiac-gated spin-echo echo-planar imaging: a feasibility study.

Huiming Dong1,2, Ning Jin3, Stephan Kannengiesser4, Brian Raterman1, Richard D White1,2,5, Arunark Kolipaka1,2,5.   

Abstract

INTRODUCTION: Magnetic resonance elastography (MRE)-derived aortic stiffness is a potential biomarker for multiple cardiovascular diseases. Currently, gradient-recalled echo (GRE) MRE is a widely accepted technique to estimate aortic stiffness. However, multi-slice GRE MRE requires multiple breath-holds (BHs), which can be challenging for patients who cannot consistently hold their breath. The aim of this study was to investigate the feasibility of a multi-slice spin-echo echo-planar imaging (SE-EPI) MRE sequence for quantifying in vivo aortic stiffness using a free-breathing (FB) protocol and a single-BH protocol.
METHOD: On Scanner 1, 25 healthy subjects participated in the validation of FB SE-EPI against FB GRE. On Scanner 2, another 15 healthy subjects were recruited to compare FB SE-EPI with single-BH SE-EPI. Among all volunteers, five participants were studied on both scanners to investigate the inter-scanner reproducibility of FB SE-EPI aortic MRE. Bland-Altman analysis, Lin's concordance correlation coefficient (LCCC) and coefficient of variation (COV) were evaluated. The phase-difference signal-to-noise ratios (PD SNR) were compared.
RESULTS: Aortic MRE using FB SE-EPI and FB GRE yielded similar stiffnesses (paired t-test, P = 0.19), with LCCC = 0.97. The FB SE-EPI measurements were reproducible (intra-scanner LCCC = 0.96) and highly repeatable (LCCC = 0.99). The FB SE-EPI MRE was also reproducible across different scanners (inter-scanner LCCC = 0.96). Single-BH SE-EPI scans yielded similar stiffness to FB SE-EPI scans (LCCC = 0.99) and demonstrated a low COV of 2.67% across five repeated measurements.
CONCLUSION: Multi-slice SE-EPI aortic MRE using an FB protocol or a single-BH protocol is reproducible and repeatable with advantage over multi-slice FB GRE in reducing acquisition time. Additionally, FB SE-EPI MRE provides a potential alternative to BH scans for patients who have challenges in holding their breath.
© 2020 John Wiley & Sons, Ltd.

Entities:  

Keywords:  aortic stiffness, free-breathing, gradient-recalled echo, MR elastography, single breath-hold, spin-echo echo-planar imaging

Mesh:

Year:  2020        PMID: 33021342     DOI: 10.1002/nbm.4420

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  3 in total

1.  MR Elastography of Abdominal Aortic Aneurysms: Relationship to Aneurysm Events.

Authors:  Huiming Dong; Brian Raterman; Richard D White; Jean Starr; Patrick Vaccaro; Mounir Haurani; Michael Go; Mariah Eisner; Guy Brock; Arunark Kolipaka
Journal:  Radiology       Date:  2022-05-31       Impact factor: 29.146

2.  Magnetic Resonance Elastography of Intervertebral Discs: Spin-Echo Echo-Planar Imaging Sequence Validation.

Authors:  Megan Co; Huiming Dong; Daniel J Boulter; Xuan V Nguyen; Safdar N Khan; Brian Raterman; Brett Klamer; Arunark Kolipaka; Benjamin A Walter
Journal:  J Magn Reson Imaging       Date:  2022-03-15       Impact factor: 5.119

Review 3.  Review of treatment and therapeutic targets in brain arteriovenous malformation.

Authors:  Peipei Pan; Shantel Weinsheimer; Daniel Cooke; Ethan Winkler; Adib Abla; Helen Kim; Hua Su
Journal:  J Cereb Blood Flow Metab       Date:  2021-06-23       Impact factor: 6.960

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.