Precision of glucose measurements in control sera by isotope dilution/mass spectrometry: proposed definitive method compared with a reference method.

O Pelletier, C Arratoon.   

Abstract

This improved isotope-dilution gas chromatographic/mass spectrometric (GC/MS) method, in which [13C]glucose is the internal standard, meets the requirements of a Definitive Method. In a first study with five reconstituted lyophilized sera, a nested analysis of variance of GC/MS values indicated considerable among-vial variation. The CV for 32 measurements per serum ranged from 0.5 to 0.9%. However, concentration and uncertainty values (mmol/L per gram of serum) assigned to one serum by the NBS Definitive Method (7.56 +/- 0.28) were practically identical to those obtained with the proposed method (7.57 +/- 0.20). In the second study, we used twice more [13C]glucose diluent to assay four serum pools and two lyophilized sera. The CV ranged from 0.26 to 0.5% for the serum pools and from 0.28 to 0.59% for the lyophilized sera. In comparison, results by the hexokinase/glucose-6-phosphate dehydrogenase reference method agreed within acceptable limits with those by the Definitive Method but tended to be slightly higher (up to 3%) for lyophilized serum samples or slightly lower (up to 2.5%) for serum pools.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3301068

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  7 in total

1.  Glucose information for tight glycemic control: different methods with different challenges.

Authors:  Christian Weber; Kurt Neeser
Journal:  J Diabetes Sci Technol       Date:  2010-09-01

2.  Evaluation of different POCT devices for glucose measurement in a clinical neonatal setting.

Authors:  Matthias Roth-Kleiner; Corinne Stadelmann Diaw; Jocelyne Urfer; Christiane Ruffieux; Dominique Werner
Journal:  Eur J Pediatr       Date:  2010-06-24       Impact factor: 3.183

Review 3.  Assessing the analytical performance of systems for self-monitoring of blood glucose: concepts of performance evaluation and definition of metrological key terms.

Authors:  Oliver Schnell; Rolf Hinzmann; Bernd Kulzer; Guido Freckmann; Michael Erbach; Volker Lodwig; Lutz Heinemann
Journal:  J Diabetes Sci Technol       Date:  2013-11-01

4.  Suboptimal performance of blood glucose meters in an antenatal diabetes clinic.

Authors:  Nimalie Jacintha Perera; Lynda Molyneaux; Maria Ines Constantino; Marg McGill; Dennis Koon-See Yue; Stephen Morris Twigg; Glynis Pauline Ross
Journal:  Diabetes Care       Date:  2011-01-07       Impact factor: 19.112

5.  Different glucose analyzers report different glucose concentration values in term newborns.

Authors:  Rina P Duke; Shasha Bai; Joshua A Bornhorst; Nahed O ElHassan; Jeffrey R Kaiser
Journal:  Front Pediatr       Date:  2022-09-21       Impact factor: 3.569

6.  Effects of endotoxin on lactate metabolism in humans.

Authors:  Burkhard Michaeli; Alexandre Martinez; Jean-Pierre Revelly; Marie-Christine Cayeux; René L Chioléro; Luc Tappy; Mette M Berger
Journal:  Crit Care       Date:  2012-07-27       Impact factor: 9.097

7.  Evaluation of three glucometers for whole blood glucose measurements at the point of care in preterm or low-birth-weight infants.

Authors:  Joon Ho Hwang; Yong-Hak Sohn; Seong-Sil Chang; Seung Yeon Kim
Journal:  Korean J Pediatr       Date:  2015-08-21
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.