| Literature DB >> 33002090 |
Cody Hansen1, Karine D Bojikian2, Zhongdi Chu3, Xiao Zhou3, Qinqin Zhang3, Raghu C Mudumbai2, Murray A Johnstone2, Ruikang K Wang2,3, Philip P Chen2.
Abstract
PURPOSE: To investigate the relationships between global and sectoral macular vascular microcirculation parameters in the ganglion cell-inner plexiform layer (GCIPL) assessed by optical coherence tomography angiography (OCTA), and global and sectoral visual field (VF) central mean sensitivity (CMS) assessed by standard automated perimetry.Entities:
Mesh:
Year: 2020 PMID: 33002090 PMCID: PMC7529279 DOI: 10.1371/journal.pone.0240111
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Fig 1Representation of cluster of central 12 points on 24–2 Humphrey visual field (CMS–central mean sensitivity) (A) and corresponding sectors on macular scans (B, C). SN = super-nasal, IN-infero-nasal, ST = supero-temporal, IT = infero-temporal, I = inferior, S = superior.
Baseline information and optical coherence tomography angiography findings in the macular ganglion cell inner plexiform layer among glaucoma subjects (N = 54).
| Glaucoma (N = 54) | |
|---|---|
| Age (y) | 69.4 ± 12.3 |
| Male / Female | 33 (61.1%) / 21 (39.9%) |
| Systolic Blood Pressure (mmHg) | 127.7 ± 16.8 |
| Diastolic Blood Pressure (mmHg) | 78.3 ± 9.2 |
| MOPP (mmHg) | 52.3 ± 8.0 |
| Systemic Hypertension, n (%) | 23 (42.6%) |
| Diabetes Mellitus, n (%) | 5 (9.3%) |
| Systemic Hypertension Medications, Yes | 22 (40.7%) |
| Glaucoma Severity | |
| Mild | 27 (50.0%) |
| Moderate | 14 (25.9%) |
| Severe | 13 (24.1%) |
| Intraocular Pressure (mmHg) | 12.7 ± 3.3 |
| Number Glaucoma Medications | 2.0 ± 1.2 |
| Central Corneal Thickness μ | 536.2 ± 34.6 |
| History of Glaucoma Surgery, Yes | 11 (20.4%) |
| Cup-to-disc Ratio | 0.78 ± 0.15 |
| VF MD (dB) | -7.9 ± 7.6 |
| VF PSD (dB) | 6.9 ± 4.3 |
| VF CMS Parafoveal Area (1/L) | 612.8 ± 307.3 |
| VF CMS SN Area (1/L) | 554.9 ± 374.6 |
| VF CMS IN Area (1/L) | 665.5 ± 336.0 |
| VF CMS ST Area (1/L) | 649.4 ± 372.4 |
| VF CMS IT Area (1/L) | 777.4 ± 298.7 |
| RNFL Thickness (μm) | 61.6 ± 14.1 |
| Global GCIPL Flux | 0.255 ± 0.029 |
| Global GCIPL | 0.480 ± 0.048 |
| Vessel Area Density | |
| Global GCIPL Vessel Diameter | 13.598 ± 0.253 |
| Global GCIPL | |
| Vessel Skeleton Density | 0.246 ± 0.023 |
| Global GCIPL Vessel Perimeter Index | 0.450 ± 0.043 |
| Global GCIPL Vessel Complexity Index | 6215.59 ± 573.06 |
MOPP = mean ocular perfusion pressure, RNFL = retinal nerve fiver layer; VF = visual field; MD = mean deviation, PSD = pattern standard deviation, CMS = central mean sensitivity GCIPL = ganglion cell inner plexiform layer.
Pearson correlation results between global GCIPL thickness and global OCTA parameters, and other functional and structural clinical measurements (N = 54).
| Global GCIPL Thickness (μm) Correlation (r) | Global GCIPL Flux | Global GCIPL VAD | ||||
|---|---|---|---|---|---|---|
| Correlation (r) | Correlation (r) | |||||
| GCIPL Thickness (μm) | 0.526 | 0.228 | 0.094 | |||
| Cup-to-disc Ratio | -0.349 | -0.532 | -0.586 | |||
| VF MD (dB) | 0.390 | 0.624 | 0.623 | |||
| VF PSD (dB) | -0.221 | 0.109 | -0.486 | -0.516 | ||
| Global VF CMS parafoveal area (1/L) | 0.272 | 0.629 | 0.718 |
VF = visual field, MD = mean deviation, PSD = pattern standard deviation, CMS = central mean sensitivity GCIPL = ganglion cell inner plexiform layer, VAD = vessel area density.
Pearson correlation between global OCTA parameters global visual field sensitivities for the glaucoma patients (N = 54).
| Correlation (r =) | ||
|---|---|---|
| Global GCIPL flux and Global VF CMS | 0.629 | |
| Global GCIPL vessel area density and Global VF CMS | 0.718 | |
| Global GCIPL vessel diameter and Global VF CMS | 0.159 | 0.251 |
| Global GCIPL vessel skeleton density and Global VF CMS | 0.713 | |
| Global GCIPL vessel perimeter index and Global VF CMS | 0.708 | |
| Global GCIPL vessel complexity index and Global VF CMS | 0.691 |
VF = visual field, CMS = central mean sensitivity GCIPL = ganglion cell inner plexiform layer.
Pearson correlation between sectoral OCTA parameters and sectoral visual field sensitivities for the glaucoma patients (N = 54).
| Correlation (r =) | ||
|---|---|---|
| IT GCIPL vessel area density and SN VF CMS | 0.559 | |
| ST GCIPL vessel area density and IN VF CMS | 0.228 | 0.097 |
| IN GCIPL vessel area density and ST VF CMS | 0.539 | |
| I GCIPL vessel area density and ST VF CMS | 0.683 | |
| SN GCIPL vessel area density and IT VF CMS | 0.462 | |
| S GCIPL vessel area density and IT VF CMS | 0.683 |
VF = visual field, CMS = central mean sensitivity GCIPL = ganglion cell inner plexiform layer, SN = super-nasal, IN-infero-nasal, ST = supero-temporal, IT = infero-temporal, I = inferior, S = superior.
Pearson correlation between sectoral OCTA parameters and sectoral visual field sensitivities for the glaucoma patients according to the structure-function correspondence map suggested by Garway-Heath et al. (N = 54).
| Vessel diameter | Vessel skeleton density | Vessel perimeter index | Vessel complexity index | |||||
|---|---|---|---|---|---|---|---|---|
| Correlation | Correlation | Correlation | Correlation | |||||
| IT GCIPL and SN VF CMS | -0.032 | 0.818 | 0.547 | 0.544 | -0.267 | 0.051 | ||
| ST GCIPL and IN VF CMS | -0.033 | 0.815 | 0.245 | 0.075 | 0.240 | 0.080 | 0.137 | 0.324 |
| IN GCIPL and ST VF CMS | -0.081 | 0.561 | 0.560 | 0.540 | -0.072 | 0.604 | ||
| I GCIPL ST VF CMS | 0.022 | 0.875 | 0.659 | 0.669 | -0.246 | 0.073 | ||
| SN GCIPL and IT VF CMS | 0.072 | 0.603 | 0.481 | 0.453 | -0.306 | |||
| S GCIPL and IT VF CMS | 0.007 | 0.958 | 0.655 | 0.675 | -0.179 | 0.196 |
VF = visual field, CMS = central mean sensitivity GCIPL = ganglion cell inner plexiform layer, SN = super-nasal, IN-infero-nasal, ST = supero-temporal, IT = infero-temporal, I = inferior, S = superior.
Fig 2Scatter plots showing the correlations between the Visual Field Central Mean Sensitivity (VF CMS 1/L) and Ganglion Cell Inner Plexiform Layer OCTA global flux (A) and global vessel area density (B).