W Cary Hill1, Matthew S Hull1,2, Robert I MacCuspie1. 1. NanoSafe, Inc., 1800 Kraft Drive, Suite 107, Blacksburg, Virginia 24060, United States. 2. Institute for Critical Technology and Applied Science, Virginia Tech, Kelly Hall (MC0193), Blacksburg, Virginia 24061, United States.
Abstract
Shortages in the availability of personal protective face masks during the COVID-19 pandemic required many to fabricate masks and filter inserts from available materials. While the base filtration efficiency of a material is of primary importance when a perfect seal is possible, ideal fit is not likely to be achieved by the average person preparing to enter a public space or even a healthcare worker without fit-testing before each shift. Our findings suggest that parameters including permeability and pliability can play a strong role in the filtration efficiency of a mask fabricated with various filter media, and that the filtration efficiency of loosely fitting masks/respirators against ultrafine particulates can drop by more than 60% when worn compared to the ideal filtration efficiency of the base material. Further, a test method using SARS-CoV-2 virion-sized silica nanoaerosols is demonstrated to assess the filtration efficiency against nanoparticulates that follow air currents associated with mask leakage.
Shortages in the availability of personal protective face masks during the COVID-19 pandemic required many to fabricate masks and filter inserts from available materials. While the base filtration efficiency of a material is of primary importance when a perfect seal is possible, ideal fit is not likely to be achieved by the average person preparing to enter a public space or even a healthcare worker without fit-testing before each shift. Our findings suggest that parameters including permeability and pliability can play a strong role in the filtration efficiency of a mask fabricated with various filter media, and that the filtration efficiency of loosely fitting masks/respirators against ultrafine particulates can drop by more than 60% when worn compared to the ideal filtration efficiency of the base material. Further, a test method using SARS-CoV-2 virion-sized silica nanoaerosols is demonstrated to assess the filtration efficiency against nanoparticulates that follow air currents associated with mask leakage.
Entities:
Keywords:
COVID-19; aerosol; exposure testing; face mask; filtration; mask fit
The use of masks and respirators as personal protective equipment (PPE) has garnered
significant attention during the COVID-19 pandemic.[1−4] Shortages of certified PPE[5] (e.g., N95
and P100 respirators) required the general public and healthcare workers to
fabricate practical immediate solutions from readily available materials.[6] While innovative, these improvised solutions often lack the
testing required to verify their efficacy against penetration by external
aerosols.Multiple research groups have reported the performance of improvised filter
materials.[2,4,7,8] Their
findings have proven useful in discovering broadly available materials that can
provide effective filtration against possible virus-carrying particulates. To
date, these studies generally measure filtration efficiency of a base filter media
in an ideal-fit scenario, where materials are challenged within a sealed container
and leakage is not considered. Proper fit is important, and air permeability of
the filter material plays a role in where particles may travel in a loosely
fitting mask, especially where smaller particulates are concerned which may more
easily follow air vectors[9,10] around an imperfect fit.There is a critical knowledge gap between understanding the dependencies on the
relationship between filter material properties and mask fit. Indeed, one of the
benchmark testing standards, ASTM F2299:2017 “Standard Test Method for
Determining the Initial Efficiency of Materials Used in Medical Face Masks to
Penetration by Particulates Using Latex Spheres”, calls out many of these
limitations, including that it “does not assess the overall effectiveness
of medical face masks in preventing the inward leakage of harmful
particles”.[11] This shortcoming has been
demonstrated in the testing of medical masks before;[12] while
the base material used to make common medical masks may demonstrate strong
filtration efficiency according to established methods, the masks themselves often
fail a basic quantitative fit test due to poor fit and resulting leakage.[13]A multitude of experts have proclaimed that airborne transmission of COVID-19 is a
major and even primary source of the spread of the virus.[14,15] Use of face masks
in public is especially critical to the reduction of virion exhalation by carriers
of the virus; face masks significantly reduce the travel distance and
concentration of virus-carrying particulates exhaled from the nose and mouth of
COVID-19-positive individuals.[1,3] It is the opinion of the U.S. Centers for
Disease Control and Prevention (CDC) and multiple research teams that the wearing
of masks in public should be strongly encouraged due to the scientific evidence
that mask usage reduces transmission from virus carrying individuals, whether they
are symptomatic, presymptomatic, or asymptomatic.[1,3,8,16] Recent evidence has shown, for instance, when two Missouri
hair salon employees and their customers were wearing masks and other guidelines
were followed, that symptomatic transmission of COVID-19 from the employees to the
customers was avoided when precautions were taken.[17] Therefore,
wearing masks to protect others continues to be a main focus of CDC
recommendations, i.e., “the cloth face cover is meant to protect other
people”.[18]The present work seeks to address concerns that publication of only the ideal
filtration efficiency of materials in perfectly sealed settings can give mask
wearers a false sense of security when venturing into areas of high exposure risk;
of specific concern are healthcare workers and persons known to be at-risk due to
age or pre-existing conditions. While a material or combination of materials may
reportedly offer high filtration efficiency in an ideal, well-sealed test
scenario, masks made from or combined with these materials may not provide an
equivalent level of protection when worn. Persons who must enter areas presenting
high risk of infection should be careful to wear respirators that are properly
fitted and rated for filtration efficiency according to fitted filtration
efficiency data where possible, and fit testing should be performed in
professional settings before shifts begin.Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) virions have been
reported to range from 60 to 140 nm in size, with an average size of 125 nm
typically referenced.[19] The current study was designed to
evaluate the filtration efficiency of respirators, masks, and filter media against
the smallest possible virus-carrying particulates, as recent data indicates that
COVID-19 is transmitted by both large and small particles and that small particles
are especially at risk for remaining airborne for extended
durations.[20,21] An investigation of the viability of minimally sized
particulates and individual virions as correlated to carrier particle size is
presented elsewhere.[22]A polydisperse silicon dioxide nanoaerosol was generated according to published
methods[23] and used as the challenge aerosol. Nanoaerosols
regularly produced the average particle concentrations and size distribution shown
in Figure . Summarily, a nanoaerosol
with median diameter of around 40 nm was generated by tightly controlling the
pressure and flow rate of nitrogen gas over tetraethyl orthosilicate before
passing it through a tube furnace at 850 °C and out through a diffuser for
ejection of the aerosol inside a 1.36 m3 electropolished stainless
steel enclosure built to an ANSI standard[24] with total particle
concentrations measuring around 1000000 particles/cm3. This method was
chosen over the more common salt generation techniques due to the tunability of
particle characteristics presented by the method and to offer an alternative
procedure to supplement existing published data.
Figure 1
A SiO2 nanoaerosol was generated for filtration efficiency
studies, with the peak concentration centered around 40 nm in
diameter.
A SiO2 nanoaerosol was generated for filtration efficiency
studies, with the peak concentration centered around 40 nm in
diameter.The ideal base filtration efficiency of selected materials was measured by cutting
samples into discs and clamping without tension in cartridges measuring 37 mm in
diameter. Sampling volume for filtration efficiency and pressure drop measurements
was tuned to 0.5 LPM, inducing an airflow rate of 0.0465 LPM/cm2 over
the filter media. This rate represents a similar standardized flow rate as may be
expected from a user under light activity (10–12 LPM), accounting for the
∼20× larger surface area of a typical face mask or respirator, which
will vary slightly depending upon design. All testing was performed within a Class
1000 cleanroom to provide minimal background particulate counts (<10
particles/cm3).Several commercially available masks and respirators were also tested as received
without further modification. One variety of N95 respirator was evaluated (3M
8511) as well as a generic dust mask (Rite Aid MaxiMask), a medical mask
(Medline), and a KN95 respirator (SupplyAid). A handmade dual-layer 600 thread
count cotton mask was produced according to a popular design,[25]
in which various filter materials were inserted for filtration efficiency
measurements, including a #4 coffee filter (Melitta), paper “shop”
towel (Scott), Filtrete 1500 (3M), surgical wrap (Halyard), vacuum filter bag
(Shop-Vac), N95 nonwoven material (Hollingsworth and Vose), and FTR467 ULPA
material (APC Filtration, Inc.). This cotton mask design includes a metal wire
stitched into the bridge of the nose area and drawstrings on each side to enable a
closer fit.Masks/respirators were attached to a soft headform with the nasal cavity modified to
accommodate intake ports for aerosol measurement equipment, connected using
static-dissipative tubing. These masks/respirators were fitted to the headform
consistently using physical markers to ensure equivalent fit across tested
materials, with qualitative visual and tactile inspection to ensure that no
obvious gaps or crevices were present. This method was followed in lieu of
quantitative fit testing in keeping with resources available to a typical user of
a homemade face mask (namely, providing best fit possible by touch and sight) in
order to capture filtration efficiency of masks in a real-use scenario. Further,
quantitative fit testing (i.e., using TSI Portacount) cannot differentiate between
particles that penetrate the filter media versus particles that leak through areas
of poor fit; fit factor is quantified as the ratio of measured particulate
concentration outside versus inside the mask or respirator, where any particulates
measured inside the mask are assumed to have arrived due to leakage. As many of
the tested mask materials do not provide highly efficient particulate filtration,
quantitative fit testing by existing methods is not appropriate. Instead, removal
and reattachment of the masks between samplings was conducted to capture the
statistical variance associated with this necessarily qualitative method,
providing a quantitative measure of repeatability.Nanoaerosol measurements were made using a Nanoscan 3910 scanning mobility particle
sizer (SMPS; TSI, Inc.), sampling 0.5 LPM. Detailed measurements were taken at
particle sizes of 60 and 125 nm at a rate of 1 per second for a total of 180 s per
sample, with samples taken in triplicate for a total of at least 540 measurements
per filter media tested. These two particle sizes were chosen to represent the
minimum and average reported SARS-CoV-2 virion size, respectively.[19]The experimental configuration for ideal base filtration testing is illustrated in
Figure (left). The
SiO2 challenge aerosol described previously was generated in an
electropolished steel environmental chamber designed according to the
specifications of ANSI/CAN/UL 2904, measuring 4′ × 3′ ×
3′ with cleanroom air (background total particulate concentration <10
particles/cm3) injected at a rate sufficient to induce one full
chamber air exchange per hour. Ports at the top of the chamber allowed for intake
of the challenge aerosol, which passed through the sealed 37 mm cartridge on its
way to the characterization equipment. A blank 37 mm cartridge was inserted for
measurement of unfiltered aerosol concentration immediately before the measurement
of every filter media sample, which formed the basis for filtration efficiency
calculations. By this method, ideal filtration efficiency of various media using
methods similar to those reported previously[2,7,26] was
determined.
Figure 2
Left: The base filtration efficiency of materials was tested in-line
between a SiO2 nanoaerosol-filled chamber and a scanning
mobility particle sizer (SMPS). Right: The filtration efficiency in
mask form was tested using a soft headform modified with sampling
ports in the nasal cavity. Components are not shown to scale.
Left: The base filtration efficiency of materials was tested in-line
between a SiO2 nanoaerosol-filled chamber and a scanning
mobility particle sizer (SMPS). Right: The filtration efficiency in
mask form was tested using a soft headform modified with sampling
ports in the nasal cavity. Components are not shown to scale.Filtration efficiency of masks and respirators (whether as-received in the case of
commercial items or as-inserted in a 2-layer cotton mask in the case of filter
media) was measured using the setup illustrated in Figure (right). Alterations between the mask and ideal
filtration testing setups were limited to the insertion of the headform into the
chamber and the corresponding sampling location (located an equivalent distance
from the diffuser as in the previous arrangement, albeit laterally rather than
vertically). Samples were collected from a background line measuring the aerosol
concentration just outside the mask/respirator immediately before the measurement
of aerosol concentration through the nose of the masked headform in order to
provide evaluation of filtration efficiency. Sampling occurred at a rate of 0.5
LPM; increasing the rate of airflow to 12 LPM by the addition of a second sampling
pump through the second nostril of the headform did not significantly alter
filtration efficiency measurements (measured particulate concentration changed by
no more than 10% with the introduction of additional airflow).The pressure drop across filter materials was measured using a dual input
differential manometer (HHP886, Omega). Filter materials were mounted within the
same 37 mm cartridge used for base filtration efficiency tests during pressure
drop measurements at a rate of 0.5 LPM.The base filtration efficiency of each tested mask material, as tested under ideal
filtration circumstances within a sealed 37 mm cartridge, is reported in Figure . A single layer of 600 thread
count cotton provided the lowest measured filtration efficiency (26.2% and 17.4%
efficiency at filtering 60 and 125 nm particles, respectively), whereas a double
layer of nonwoven N95 material and single layers of KN95, 3M 8511, and FTR467 ULPA
materials demonstrated better than 98% filtration efficiency of both particulate
sizes.
Figure 3
Base filtration efficiency of each tested fabric ranged from as low as
17.4% to greater than 99.98%.
Base filtration efficiency of each tested fabric ranged from as low as
17.4% to greater than 99.98%.The measured pressure drop across each filter material as a means for quantifying
relative air permeability is reported in Figure .
Figure 4
Measured pressure drops across filter media were largely similar; the
FTR467 ULPA material exhibited a pressure drop that would likely
preclude use in a passive filtration mask, as it is designed for use
in pleated, high surface area filter cartridges for powered
applications.
Measured pressure drops across filter media were largely similar; the
FTR467 ULPA material exhibited a pressure drop that would likely
preclude use in a passive filtration mask, as it is designed for use
in pleated, high surface area filter cartridges for powered
applications.The filtration efficiency of all materials dropped significantly in mask form
compared with the base ideal filtration efficiency of the material itself (Figure ). Few materials provided a
significant increase in filtration efficiency over the cotton mask. Notably, the
dust mask provided negligible protection against 60 and 125 nm particles.
Figure 5
When inserted into a 2-layer cotton mask, all filter materials exhibited
a significant drop in filtration efficiency compared to the measured
base filtration efficiency. The 3M 8511 and KN95 respirators as well
as the medical and dust masks were all tested as-received in mask
form, whereas the remainder were tested through insertion between the
two layers of the cotton mask. A KN95 respirator that was sealed to
the headform before testing with thermoplastic adhesive (i.e. to
demonstrate a leak-free fit) provided filtration efficiency very near
to its base filtration efficiency, proving that the cause of
efficiency reductions was related primarily to fit quality.
When inserted into a 2-layer cotton mask, all filter materials exhibited
a significant drop in filtration efficiency compared to the measured
base filtration efficiency. The 3M 8511 and KN95 respirators as well
as the medical and dust masks were all tested as-received in mask
form, whereas the remainder were tested through insertion between the
two layers of the cotton mask. A KN95 respirator that was sealed to
the headform before testing with thermoplastic adhesive (i.e. to
demonstrate a leak-free fit) provided filtration efficiency very near
to its base filtration efficiency, proving that the cause of
efficiency reductions was related primarily to fit quality.The 3M 8511 and KN95 respirators excelled in the base media filtration efficiency
measurements, achieving greater than 98% filtration efficiency of the
SiO2 nanoaerosol. However, when fit to the headform as reported
in Figure , filtration efficiency
dropped to less than 40%, slightly better than the fitted cotton mask. To verify
that this drop in efficiency was due to fit quality as opposed to other
considerations (such as leakage at seams on the manufactured product), KN95
respirators were also sealed to the headform using a thermoplastic adhesive to
provide a leak-free fit and tested. When sealed, the KN95 respirators provided
filtration efficiency (Figure ) very
near to the base KN95 material filtration efficiency reported previously in Figure (96.7 ± 0.2% when sealed to
the headform compared to 98.1 ± 1.6% base filtration efficiency of the KN95
material against 60 nm SiO2 particles).Most tested materials did not significantly improve cotton mask performance as an
insert even if excellent base filtration efficiency was exhibited; in most cases,
the cotton mask offered practically equivalent levels of protection without the
insertion of the extra layer.Among insert filter materials that did significantly increase filtration efficiency,
air permeability and pliability appear to be important factors. If a material is
relatively impermeable, airflows (and the aerosols they carry) may be more likely
to follow contours around the mask into leaks and other areas of low resistance
rather than seek to penetrate the filter material; cascade impactors take
advantage of similar principles of differential inertia in order to segregate
particulates by size.[27] More pliable materials were observed to
qualitatively fit and fill the cotton mask more effectively, allowing for a closer
fit to the face, reducing opportunities for leaks. Illustratively, while the
FTR467 ULPA material exhibited the best base filtration efficiency of all measured
materials (better than 99.8%), it provided the worst protection as an insert,
offering no additional protection over the unfilled cotton mask; it was also the
least permeable and least pliable material tested. Similarly, while a double layer
of N95 material provided excellent filtration efficiency in base measurements
while maintaining adequate permeability, its relative stiffness appears to have
limited its efficacy as a cotton mask insert, though other unidentified factors
may have also contributed. The highest performing mask insert materials (the
surgical wrap and ShopVac materials) exhibited a combination of strong base
filtration efficiency and air permeability and were also among the most
qualitatively pliable of the tested materials. There are likely other factors such
as electrostatic interactions at play that were not quantified during these
experiments. These results suggest that a combination of pliability and
permeability should be considered alongside suspected or measured filtration
efficiency when choosing a material for homemade mask or mask insert.Fit clearly plays a critical role in the ability of a mask or respirator to protect
its user from particulate inhalation. The as-received items did not show nearly
the filtration efficiency when worn by the headform as was measured in base form
despite apparent visual and tactile fit across the face of the headform, unless
great effort was taken to seal the respirator–skin interface using
adhesive. The bridge of the nose provides the most exaggerated contour difference
and therefore presents the most likely region where leaks will be present,
followed by the chin and jawline. These features may vary greatly across
individuals, exacerbating fit issues; further research is needed to perform
equivalent measurements using headforms of a range of representative dimensions to
quantify how fit variance affects filtration efficiency.In conclusion, our results demonstrate the importance of fit on filtration
efficiency. Two outcomes are desired; first, while wearing a homemade mask can and
does significantly reduce virion-sized particulate exposure (as-worn filtration
efficiencies of 15–40% are reported here), masks of this style cannot
provide the level of protection measured and more commonly reported in ideal-fit
scenarios. Users should, therefore, exercise caution when entering areas of high
exposure risk and consider using PPE known to create a better sealed fit, such as
a half- or full-face respirator, when contact with infectedpersons is inevitable,
and perform quantitative fit testing before shifts where possible. These
implications also hold true for mask and respirator usage in other activities
(such as construction), as fit affects the ability of the mask or respirator to
protect the wearer against ultrafine particulates represented by the
SiO2 nanoaerosol used in this study.Second, those seeking to create new PPE designs should prioritize the integration of
fit testing along with penetration testing; we suspect the greatest source of
leakage remains around the bridge of the nose. Innovation ensuring a better seal
could provide a greater return in overall reduced viral exposure compared to the
expenditure of effort toward improving base material filtration efficiency.It should also be noted that researchers have recently hypothesized that usage of
masks that block large droplets but remain vulnerable to smaller aerosols may
actually contribute to the development of immunity and occurrence of infection
with reduced COVID-19-related symptoms.[28] In essence, allowing
leakage of small particles that carry a lower viral load is suggested to provide
opportunity for inoculation without overwhelming bodily defenses. If this nascent
theory holds true, then the leakage of small aerosols in mild exposure situations
may actually benefit the wearer (though vulnerable populations and those entering
areas with known high exposure potential may still wish to take fullest
precautions).Mask usage remains a critical part of reducing exposure, lowering the rate of
infection, and allowing economies to remain open in some capacity during a
pandemic; these findings do not diminish the well-demonstrated fact that masks
significantly reduce the travel distance and concentration of droplets and
aerosols released by the mask wearer. Greater understanding of the relationship
between filter media properties, mask fit, and filtration efficiency will lead to
PPE configurations that afford better levels of protection to users while the
activities required to sustain life are conducted.