Literature DB >> 32978269

Review of current intracranial aneurysm flow diversion technology and clinical use.

Sudeepta Dandapat1, Alan Mendez-Ruiz1, Mario Martínez-Galdámez2, Juan Macho3,4, Shahram Derakhshani3, Gustavo Foa Torres5, Vitor M Pereira6,7, Anil Arat8, Ajay K Wakhloo9, Santiago Ortega-Gutierrez10,11.   

Abstract

Endovascular treatment of intracranial aneurysms (IAs) has evolved considerably over the past decades. The technological advances have been driven by the experience that coils fail to completely exclude all IAs from the blood circulation, the need to treat the diseased parent vessel segment leading to the aneurysm formation, and expansion of endovascular therapy to treat more complex IAs. Stents were initially developed to support the placement of coils inside wide neck aneurysms. However, early work on stent-like tubular braided structure led to a more sophisticated construct that then later was coined as a flow diverter (FD) and found its way into clinical application. Although FDs were initially used to treat wide-neck large and giant internal carotid artery aneurysms only amenable to surgical trap with or without a bypass or endovascular vessel sacrifice, its use in other types of IAs and cerebrovascular pathology promptly followed. Lately, we have witnessed an explosion in the application of FDs and subsequently their modifications leading to their ubiquitous use in endovascular therapy. In this review we aim to compile the available FD technology, evaluate the devices' peculiarities from the authors' perspective, and analyze the current literature to support initial and expanded indications, recognizing that this may be outdated soon. © Author(s) (or their employer(s)) 2021. No commercial re-use. See rights and permissions. Published by BMJ.

Entities:  

Keywords:  aneurysm; device; fistula; flow diverter

Year:  2020        PMID: 32978269     DOI: 10.1136/neurintsurg-2020-015877

Source DB:  PubMed          Journal:  J Neurointerv Surg        ISSN: 1759-8478            Impact factor:   5.836


  12 in total

1.  Follow-up of Intracranial Aneurysms Treated by Flow Diverters: Evaluation of Parent Artery Patency Using 3D-T1 Gradient Recalled-Echo Imaging with 2-Point Dixon in Combination with 3D-TOF-MRA with Compressed Sensing.

Authors:  J Burel; E Gerardin; M Vannier; A Curado; M Verdalle-Cazes; N Magne; M Lefebvre; C Papagiannaki
Journal:  AJNR Am J Neuroradiol       Date:  2022-03-03       Impact factor: 3.825

2.  Endovascular treatment of a ruptured aneurysm arising from the proximal end of a partial vertebrobasilar duplication with a contralateral prominent persistent primitive hypoglossal artery: illustrative case.

Authors:  Nobuyuki Genkai; Kouichirou Okamoto; Toshiharu Nomura; Hiroshi Abe
Journal:  J Neurosurg Case Lessons       Date:  2021-05-10

3.  Ultra-Short-Term Dual Antiplatelet Therapy in Treating Unruptured Brain Aneurysm With the Pipeline Flex-Shield Embolization Device.

Authors:  Adam Delora; Obadah Ezzeldin; Uzma Ali; Mohammad El-Ghanem; Mohamad Ezzeldin
Journal:  Cureus       Date:  2022-05-31

4.  A novel intracranial exchange guidewire improves the navigation of various endovascular devices: An in vitro study of challenging situations.

Authors:  Naoki Kaneko; Ariel Takayanagi; Hamidreza Saber; Lea Guo; Satoshi Tateshima
Journal:  Interv Neuroradiol       Date:  2021-11-17       Impact factor: 1.764

5.  Endovascular treatment of pancreaticoduodenal aneurysm with braided stent-assisted coil embolization using intraoperative cone-beam computed tomography guidance.

Authors:  Marton Berczeli; Ponraj Chinnadurai; Ross G McFall; Orlando Diaz; Alan B Lumsden
Journal:  J Vasc Surg Cases Innov Tech       Date:  2022-03-31

6.  Retrospective analysis of intracranial aneurysms after flow diverter treatment including color-coded imaging (syngo iFlow) as a predictor of aneurysm occlusion.

Authors:  Andreas Simgen; Christine Mayer; Michael Kettner; Ruben Mühl-Benninghaus; Wolfgang Reith; Umut Yilmaz
Journal:  Interv Neuroradiol       Date:  2021-06-09       Impact factor: 1.764

7.  Hemodynamic Analysis of Pipeline Embolization Device Stent for Treatment of Giant Intracranial Aneurysm under Unsupervised Learning Algorithm.

Authors:  Haibin Gao; Wei You; Jian Lv; Youxiang Li
Journal:  J Healthc Eng       Date:  2022-01-04       Impact factor: 2.682

8.  Critical Angiographic and Sonographic Analysis of Intra Aneurysmal and Downstream Hemodynamic Changes After Flow Diversion.

Authors:  Radoslav Raychev; Stanimir Sirakov; Alexander Sirakov; Hamidreza Saber; Fernando Vinuela; Reza Jahan; May Nour; Viktor Szeder; Geoffrey Colby; Gary Duckwiler; Satoshi Tateshima
Journal:  Front Neurol       Date:  2022-03-10       Impact factor: 4.003

9.  Endovascular Treatment of Posterior Circulation Saccular Aneurysms With the p64 Flow Modulation Device: Mid-and Long-Term Results in 54 Aneurysms From a Single Center.

Authors:  Victoria Hellstern; Marta Aguilar-Pérez; Elina Henkes; Carmen Serna-Candel; Christina Wendl; Hansjörg Bäzner; Oliver Ganslandt; Hans Henkes
Journal:  Front Neurol       Date:  2021-07-16       Impact factor: 4.003

10.  Risk factors of intracranial infection in patients after intracranial aneurysm surgery: Implication for treatment strategies.

Authors:  Xiaohong Guo; Junkang Fang; Yi Wu
Journal:  Medicine (Baltimore)       Date:  2021-12-03       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.