Haitham AlRabiah1, Sabry M Attia2, Nasser S Al-Shakliah1, Gamal A E Mostafa1,3.
Abstract
An accurate and simple HPLC-UV method has been developed for the determination of clonidine in mouse plasma. A reversed phase C18 Nova Pack® column (125 mm × 4.6 mm i.d., × 3 μm particle size) was used as stationary phase. The mobile phase composition was a mixture of 0.1% diethylamine/acetonitrile (70:30, v/v) at pH 8 in an isocratic mode at flow rate was 1.0 mL/min. Detection was set at 210 nm. Tizanidine was used as an internal standard. The clonidine and tizanidine were extracted from plasma matrix using the deproteinization technique. The developed method exhibited a linear calibration range 100.0-2000 ng/mL and the lower limit of detection (LOD) and quantification (LOQ) were 31.0 and 91.9 ng/mL, respectively. The intra-day and inter-day accuracy and precision of the method were within 8.0% and 3.0%, respectively, relative to the nominal concentration. The developed method was validated with respect to linearity, accuracy, precision, and selectivity according to the US Food and drug guideline. Minimal degradation was demonstrated during the determination of clonidine under different stability conditions. The suggested method has been successfully applied during a pharmacokinetic study of clonidine in mouse plasma.Entities:
Keywords: HPLC; clonidine; detection method; mouse plasma; pharmacokinetic study
Mesh:
Substances:
Year: 2020 PMID: 32911847 PMCID: PMC7571031 DOI: 10.3390/molecules25184109
Source DB: PubMed Journal: Molecules ISSN: 1420-3049 Impact factor: 4.411
Figure 1Chemical structure of (A) clonidine and (B) tizanidine (IS).
System suitability parameters.
| Parameters | RT * | K | Selectivity | Resolution | Symmetry Factor |
|---|---|---|---|---|---|
| IS | 5.0 | 89.48 | 1.5 | - | 1.06 |
| Clonidine | 6.5 | 131.61 | 2.47 | 2.91 | 1.0 |
* RT = retention time.
Extraction of clonidine from mice plasma using the proposed HPLC method.
| Spiked (ng/mL) | Found a (ng/mL) | Recovery (%) b | RSD *, % |
|---|---|---|---|
| 100.0 | 105.0 | 105.0 | 0.29 |
| 200.0 | 216.0 | 108.0 | 0.69 |
| 400.0 | 380.0 | 95.0 | 2.24 |
| 800.0 | 748.0 | 93.5 | 0.87 |
| 1000.0 | 960.0 | 96.0 | 0.52 |
| 2000.0 | 2060.0 | 103.0 | 0.32 |
a Clonidine extracted from mice plasma; b Average recovery (repeatation = 3) (n = 3). * RSD, relative standard deviation.
Figure 2HPLC chromatogram of clonidine: (A) mouse plasma, (B) mouse plasma spiked with 1 μg/mL (Tizanidine, IS) and 200 (ng/mL) of IS and clonidine respectively (retention time was 5.002 and 6.505 (min)).
Analytical characteristic parameters of the investigated HPLC method. LOD: limit of detection, LOQ: limit of quantification.
| Parameter | Clonidine a |
|---|---|
| Slope | 0.002 |
| The standard error of the slope | 2.85 × 10−5 |
| Intercept | −0.0944 |
| The standard error of intercept | 0.03142 |
| SY/X * | 0.0168253 |
| Correlation coefficient, (r2) | 0.999 |
| Calibration range (ng/mL) | 100.0–2000.0 |
| LOD (ng/mL) | 31.0 |
| LOQ (ng/mL) | 91.9 |
| Retention time for clonidine (min) | 6.5 |
| Retention time for IS (min) | 5.0 |
a Values are the mean of three determinations.* SY/X is Standard error of Y/X.
Accuracy and precision of clonidine in spiked mice plasma using the proposed HPLC method.
| Conc. (ng/mL) | Intra-Day | Inter-Day | ||||||
|---|---|---|---|---|---|---|---|---|
| Mean | SD | RSD% | Accuracy % | Mean | SD | RSD% | Accuracy % | |
| 100 | 109.0 | 0.25 | 0.25 | 109.10 | 107.0 | 0.45 | 0.42 | 107.0 |
| 200 | 223.0 | 1.31 | 0.58 | 111. 5 | 211.0 | 1.55 | 0.73 | 105.5 |
| 500 | 481.6 | 8.5 | 1.7 | 96.3 | 478.0 | 9.4 | 1.96 | 95.6 |
| 1000 | 969.0 | 6.7 | 0.69 | 96.9 | 960.0 | 7.5 | 0.78 | 96.0 |
| 1500 | 1445.0 | 4.95 | 0.34 | 96.3 | 1400.0 | 5.1 | 0.36 | 93.3 |
| 2000 | 2068.5 | 6.4 | 0.31 | 103.4 | 2184.3 | 8.1 | 0.37 | 109.22 |
(number of repation n = 3).
Accuracy and precision of the quality control samples by the proposed HPLC.
| Conc. (ng/mL) | Intra-Day | Inter-Day | ||||||
|---|---|---|---|---|---|---|---|---|
| Mean | SD | RSD% | Accuracy % | Mean | SD | RSD% | Accuracy % | |
| 150.0 | 138.1 | 3.2 | 2.31 | 92.1 | 136.0 | 3.3 | 2.43 | 90.6 |
| 550.0 | 520.0 | 2.5 | 0.11 | 94.5 | 575.0 | 2.4 | 0.42 | 104.54 |
| 1250.0 | 1187.5 | 1.37 | 0.16 | 95.0 | 1168.75 | 2.4 | 0.21 | 93.5 |
| 1750.0 | 1680 | 1.38 | 0.10 | 96.0 | 1464.5 | 1.9 | 0.13 | 94.0 |
(number of repation (n = 3).
Stability data of clonidine in mouse plasma.
| Parameters | Bench Top for 8 h | Stability at −4 °C | Thaw Stability | ||||||
|---|---|---|---|---|---|---|---|---|---|
| Conc. ng/mL | Conc. ng/mL | Conc. ng/mL | |||||||
| 150 | 550 | 1250 | 150 | 550 | 1250 | 150 | 550 | 1250 | |
| Mean | 161.3 | 529.7 | 1213.8 | 165.3 | 530.7 | 1206.3 | 156.8 | 522.5 | 1193.8 |
| Recovery *, % | 107.5 | 96.3 | 97.1 | 110.2 | 96.5 | 96.7 | 104.5 | 95 | 95.5 |
| SD | 2.5 | 5.4 | 9.5 | 2.53 | 6.5 | 8.5 | 2.11 | 4.5 | 10.52 |
| RSD, % | 1.55 | 1.02 | 0.78 | 1.53 | 1.22 | 0.7 | 1.34 | 0.86 | 0.88 |
* Average of three determinations.
Figure 3The concentration–time curve of clonidine in mice plasma after administration with 2 mg/kg of clonidine (each point equal mean ± SD).
Figure 4HPLC chromatograms of mouse plasma sample after 3 h from administration (B) and (A) bank mouse plasma.