Jialang Zhuang1, Jiangying Chen1, Xueding Wang1, Yin Pang2, Huichang Bi1, Lihui Huang1, Guixiong Zeng1, Xiaoxing Liao3, Zhongfu Ma3, Xiao Chen3, Guoping Zhong1, Min Huang1, Xianglan Zhao1.
Abstract
A rapid and sensitive liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method to determine clonidine in human plasma was developed and fully validated. Sample preparation was involved an one-step extraction with diethyl ether. Donepezil was employed as the internal standard (IS). Chromatographic separation was performed on a Hypersil BDS C18 column (i.d. 2.1 × 50 mm, particle size 3μm) with a mobile phase of methanol-water (containing 0.1% formic acid; 60:40, v/v) at a flow rate of 200 μL/min. The peaks were detected by mass spectrometry using the electrospray ion source in selected reaction monitoring mode. The extraction recovery was 72.53-85.25%. The method was found to be linear in a concentration range of 0.02-6.00 ng/mL and the lower limit of quantification was 0.02 ng/mL. The within- and between-batch precisions at three concentrations were 4.33-16.47 and 7.24-17.24% with accuracies of -2.47-10.91 and 1.86-10.19%, respectively. This validated method was successfully used for a bioequivalence study of two clonidine transdermal patches on healthy volunteers. The results suggested that the test formulation of clonidine patch met the regulatory criterion for bioequivalence to the reference formulation, but a larger sample size should be needed for the estimation of bioequivalence.Entities:
Keywords: Clonidine; HPLC-MS/MS; bioequivalence; human plasma
Mesh:
Substances:
Year: 2015 PMID: 25776729 DOI: 10.1002/bmc.3450
Source DB: PubMed Journal: Biomed Chromatogr ISSN: 0269-3879 Impact factor: 1.902