Literature DB >> 30830964

Validation of a HPLC/MS method for simultaneous quantification of clonidine, morphine and its metabolites in human plasma.

Fei Tang1,2, Henrietta Bada3, Chee M Ng1, Markos Leggas1,2.   

Abstract

A high-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous quantification of morphine, morphine's major metabolites morphine-3-glucuronide and morphine-6-glucuronide, and clonidine, to support the pharmacokinetic analysis of an ongoing double-blinded randomized clinical trial that compares the use of morphine and clonidine in infants diagnosed with neonatal abstinence syndrome. Plasma samples were processed by solid-phase extraction and separated on an Inertsil ODS-3 (4 μm) column using an 0.1% formic acid in water-0.1% formic acid in methanol gradient. Detection of the analytes was conducted in the positive multiple reaction monitoring mode. The range of quantitation was 1-1000 ng/mL for morphine, morphine-3-glucuronide and morphine-6-glucuronide, and 0.25-100 ng/mL for clonidine. Intra-day and inter-day accuracy and precision were ≤15% for all analytes across the quantitation range. Extraction recovery rates were ≥94% for morphine, ≥90% for M3G, ≥87% for M6G and ≥ 79% for clonidine. Matrix effect ranged from 85-94% for clonidine to 101-106% for M3G. The method fulfilled all predetermined acceptance criteria and required only 100 μL of starting plasma volume. Furthermore, it was successfully applied to 30 clinical trial plasma samples.
© 2019 John Wiley & Sons, Ltd.

Entities:  

Keywords:  LC-MS/MS; clonidine; method validation; morphine; neonatal abstinence syndrome; solid-phase extraction

Mesh:

Substances:

Year:  2019        PMID: 30830964      PMCID: PMC6559858          DOI: 10.1002/bmc.4527

Source DB:  PubMed          Journal:  Biomed Chromatogr        ISSN: 0269-3879            Impact factor:   1.902


  30 in total

Review 1.  Clonidine in paediatric anaesthesia.

Authors:  K Nishina; K Mikawa; M Shiga; H Obara
Journal:  Paediatr Anaesth       Date:  1999       Impact factor: 2.556

2.  Sensitive and convenient method for the quantification of clonidine in serum of pediatric patients using liquid chromatography/tandem mass spectrometry.

Authors:  C Müller; M Ramic; S Harlfinger; C Hünseler; M Theisohn; B Roth
Journal:  J Chromatogr A       Date:  2006-11-21       Impact factor: 4.759

3.  Liquid chromatography tandem mass spectrometry method for the quantification of clonidine with LLOQ of 10 pg/mL in human plasma.

Authors:  Ramakrishna Nirogi; Vishwottam Kandikere; Koteshwara Mudigonda; Prashanth Komarneni
Journal:  Biomed Chromatogr       Date:  2008-09       Impact factor: 1.902

4.  Use of clonidine in the prevention and management of neonatal abstinence syndrome.

Authors:  Jerrold B Leikin; William P Mackendrick; Gerry E Maloney; James W Rhee; Elaine Farrell; Michael Wahl; Karen Kelly
Journal:  Clin Toxicol (Phila)       Date:  2009-07       Impact factor: 4.467

5.  Sedation and plasma concentration of clonidine hydrochloride for pre-anesthetic medication in pediatric surgery.

Authors:  Kenji Sumiya; Masato Homma; Machiko Watanabe; Yasuyuki Baba; Shin-ichi Inomata; Shin-ichi Kihara; Hidenori Toyooka; Yukinao Kohda
Journal:  Biol Pharm Bull       Date:  2003-04       Impact factor: 2.233

6.  Treatment of neonatal abstinence syndrome with clonidine and chloral hydrate.

Authors:  A Esmaeili; A K Keinhorst; T Schuster; F Beske; R Schlösser; C Bastanier
Journal:  Acta Paediatr       Date:  2009-10-19       Impact factor: 2.299

7.  Clonidine as an adjunct therapy to opioids for neonatal abstinence syndrome: a randomized, controlled trial.

Authors:  Alexander G Agthe; George R Kim; Kay B Mathias; Craig W Hendrix; Raul Chavez-Valdez; Lauren Jansson; Tamorah R Lewis; Myron Yaster; Estelle B Gauda
Journal:  Pediatrics       Date:  2009-04-27       Impact factor: 7.124

8.  Rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of clonidine in human plasma.

Authors:  Sagar A Parekh; Ashutosh Pudage; Santosh S Joshi; Vikas V Vaidya; Noel A Gomes
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2008-04-11       Impact factor: 3.205

9.  Age- and therapy-related effects on morphine requirements and plasma concentrations of morphine and its metabolites in postoperative infants.

Authors:  N J Bouwmeester; J N van den Anker; W C J Hop; K J S Anand; D Tibboel
Journal:  Br J Anaesth       Date:  2003-05       Impact factor: 9.166

Review 10.  Relationships among morphine metabolism, pain and side effects during long-term treatment: an update.

Authors:  Gertrud Andersen; Lona Christrup; Per Sjøgren
Journal:  J Pain Symptom Manage       Date:  2003-01       Impact factor: 3.612

View more
  2 in total

1.  Simultaneous detection of a panel of nine sedatives and metabolites in plasma from critically ill pediatric patients via UPLC-MS/MS.

Authors:  Jonathan Birabaharan; Raymond E West; Thomas D Nolin; Chani Traube; Michael J Bell; Philip E Empey
Journal:  J Pharm Biomed Anal       Date:  2022-05-23       Impact factor: 3.571

2.  Development and Validation of an HPLC-UV Detection Assay for the Determination of Clonidine in Mouse Plasma and Its Application to a Pharmacokinetic Study.

Authors:  Haitham AlRabiah; Sabry M Attia; Nasser S Al-Shakliah; Gamal A E Mostafa
Journal:  Molecules       Date:  2020-09-08       Impact factor: 4.411

  2 in total