| Literature DB >> 30830964 |
Fei Tang1,2, Henrietta Bada3, Chee M Ng1, Markos Leggas1,2.
Abstract
A high-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous quantification of morphine, morphine's major metabolites morphine-3-glucuronide and morphine-6-glucuronide, and clonidine, to support the pharmacokinetic analysis of an ongoing double-blinded randomized clinical trial that compares the use of morphine and clonidine in infants diagnosed with neonatal abstinence syndrome. Plasma samples were processed by solid-phase extraction and separated on an Inertsil ODS-3 (4 μm) column using an 0.1% formic acid in water-0.1% formic acid in methanol gradient. Detection of the analytes was conducted in the positive multiple reaction monitoring mode. The range of quantitation was 1-1000 ng/mL for morphine, morphine-3-glucuronide and morphine-6-glucuronide, and 0.25-100 ng/mL for clonidine. Intra-day and inter-day accuracy and precision were ≤15% for all analytes across the quantitation range. Extraction recovery rates were ≥94% for morphine, ≥90% for M3G, ≥87% for M6G and ≥ 79% for clonidine. Matrix effect ranged from 85-94% for clonidine to 101-106% for M3G. The method fulfilled all predetermined acceptance criteria and required only 100 μL of starting plasma volume. Furthermore, it was successfully applied to 30 clinical trial plasma samples.Entities:
Keywords: LC-MS/MS; clonidine; method validation; morphine; neonatal abstinence syndrome; solid-phase extraction
Mesh:
Substances:
Year: 2019 PMID: 30830964 PMCID: PMC6559858 DOI: 10.1002/bmc.4527
Source DB: PubMed Journal: Biomed Chromatogr ISSN: 0269-3879 Impact factor: 1.902