| Literature DB >> 32864061 |
Argyrios Tzamalis1,2, Myron Kynigopoulos2, Grigoris Pallas2, Ioannis Tsinopoulos1, Nikolaos Ziakas1.
Abstract
PURPOSE: To evaluate the effect of asphericity and blue light filter (BLF) of three different intraocular lenses (IOLs) on the visual performance, second- and third-order aberrations (defocus, coma, trefoil), and contrast sensitivity after uneventful cataract surgery.Entities:
Keywords: Asphericity; Blue-light Filtering; Contrast Sensitivity; Intraocular Lens; Aberrometry
Year: 2020 PMID: 32864061 PMCID: PMC7431729 DOI: 10.18502/jovr.v15i3.7449
Source DB: PubMed Journal: J Ophthalmic Vis Res ISSN: 2008-322X
Main characteristics and special features of the intraocular lenses used in the study
|
| |||
|
| Hydrophilic acrylic copolymer 26 % water | Hydrophilic acrylic copolymer | Hydrophilic acrylic |
|
| Biconvex aspherical | Biconvex aspherical | Spherical |
|
| 6.0 | 6.5 | 6.0 |
|
| 12.0 | 12.5 | 12.5 |
|
| 360º square edge | 360º reinforced edge design "pco-barrier" | 360º square edge |
|
| 0 | 5 | 5 |
|
| With BLF | Without BLF | Without BLF |
|
| 118.8 | 118.9 | 118.0 |
|
| 1.465 | 1.46 | 1.462 |
|
| 4.98 | 4.99 | 4.96 |
| BLF, blue light filtering | |||
Main demographics and clinical characteristics of the study participants
|
| |||||
|
| 21F/19M | 22/18M | 19F/21M | 0.79 | 62F/58M |
|
| 70.3 | 74.6 | 72.5 | 0.53 | 72.4 |
|
| 24.1 | 23.6 | 23.7 | 0.59 | 23.8 |
|
| 0.19 | 0.45 | 0.39 | 0.68 | 0.34 |
|
| –0.32 | –0.34 | –0.31 | 0.41 | –0.32 |
|
| 21.1 | 22.5 | 22.2 | 0.15 | 21.8 |
|
| 0.38 (0.42 | 0.29 (0.53 | 0.32 (0.48 | 0.59 | 0.33 (0.47 |
|
| 0.018 (0.96 | 0.031 (0.93 | 0.022 (0.95 | 0.59 | 0.023 (0.948 |
|
| 7.65 | 7.64 | 7.66 | 0.87 | 7.65 |
|
| 7.66 | 7.66 | 7.69 | 0.93 | 7.67 |
|
| |||||
Comparisons of second- and third-order aberrations among the three IOL groups
|
| |||
|
| –0.7842 | 0.1288 | 0.1082 |
|
| –0.6557 | 0.1573 | 0.1929 |
|
| –0.6136 | 0.1984 | 0.2058 |
|
| –0.69 | 0.16 | 0.16 |
|
| |||
|
| 0.52 | 0.11 |
|
|
| 0.59 | 0.43 |
|
|
| 0.8 | 0.36 | 0.82 |
Mean loss of contrast sensitivity, expressed in logarithmic units, from photopic to mesopic lighting conditions (LC) and under glare conditions in mesopic LC.
|
| ||||||||||
|
| 0.051 | 0.105 | 0.227 | 0.406 | 0.569 | 0.096 | 0.23 | 0.233 | 0.452 | 0.256 |
|
| 0.021 | 0.129 | 0.185 | 0.400 | 0.358 | 0.165 | 0.121 | 0.154 | 0.217 | 0.331 |
|
| 0.030 | 0.140 | 0.221 | 0.521 | 0.433 | 0.167 | 0.139 | 0.229 | 0.099 | 0.206 |
|
| 0.69 | 0.62 | 0.69 | 0.69 | 0.27 | 0.17 | 0.04 | 0.75 | 0.02 | 0.64 |
|
| 0.43 | 0.59 | 0.17 | 0.77 | 0.25 | 0.13 | 0.01 | 0.71 | 0.27 | 0.84 |
|
| 0.53 | 0.31 | 0.60 | 0.34 | 0.41 | 0.20 | 0.05 | 0.84 | 0.04 | 0.81 |
|
| 0.92 | 0.64 | 0.60 | 0.62 | 0.75 | 0.98 | 0.77 | 0.85 | 0.30 | 0.67 |
| IOL1, Bioline Yellow Accurate; IOL2, Physiol H65C/N; IOL3, BioAcryl60125; cpd, cycles per degree
| ||||||||||