Abstract

PURPOSE: To determine whether implantation of a microincision intraocular lens (IOL) with a modified anterior surface, designed to compensate for the positive spherical aberration of the cornea in eyes of cataract patients, results in improved pseudophakic quality of vision in pseudophakic eyes after biaxial microincision phacoemulsification.
SETTING: Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.
METHODS: In a nonrandomized parallel cohort investigation, the visual performance of 52 eyes of 52 patients unilaterally implanted with the aspherical Acri. Smart 36 A IOL (Acri.Tec) were compared with those of 25 eyes of 25 age-matched patients unilaterally implanted with the spherical Acri. Smart 46 S IOL (Acri.Tec). Eight weeks after surgery, the following parameters were assessed: uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), pupil size under various illumination conditions, high-contrast and low-contrast visual acuities, photopic and mesopic contrast sensitivities, capsulorhexis size, and wavefront aberration of the cornea and eye. The primary clinical endpoint of the comparison was defined as the area under the cycles per degree (cpd) curve of the contrast sensitivity profile.
RESULTS: The aspherical IOL group and the spherical IOL group did not differ in baseline characteristics. The median age was 71 years and 68% were women in the aspherical group versus 69 years and 62% women in the spherical group. The preoperative median UCVA was 20/80 in both groups. The UCVA, BCVA, pupil size, and capsulorhexis size were not statistically different between the 2 groups. Furthermore, no clinically relevant or statistically significant between-group differences were observed in the primary clinical endpoint. The median postoperative low mesopic contrast sensitivity without glare was 73 cpd in the aspherical group and 84 cpd in the spherical group (P = .624); a similar tendency was observed under high mesopic conditions (median 80 cpd and 83 cpd, respectively) (P = 1.000). Implantation of both IOL types resulted in a negative spherical aberration Z(4)(0), which was significantly different between the 2 groups (median -0.09 mum aspherical and -0.29 microm aspherical at a pupil size of 4.5 mm) (P<.001).
CONCLUSIONS: No clinically relevant postoperative differences in contrast sensitivity were observed between the aspherical microincision IOL and the spherical equivalent model. The development of microincision IOLs, which fit through corneal incisions smaller than 2.0 mm and improve night-driving conditions (eg, reduction of glare), could optimize modern biaxial cataract surgery.

Entities:  

Mesh:

Year:  2007        PMID: 17321388     DOI: 10.1016/j.jcrs.2006.10.066

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  13 in total

1.  Visual and optical performance of eyes with different corneal spherical aberration implanted with aspheric intraocular lens.

Authors:  Xian-Hui Gong; Qin-Xiang Zheng; Na Wang; Ding Chen; Juan Zhao; Jin Li; Yun-E Zhao
Journal:  Int J Ophthalmol       Date:  2012-06-18       Impact factor: 1.779

2.  Comparison of contrast sensitivity, depth of field and ocular wavefront aberrations in eyes with an IOL with zero versus positive spherical aberration.

Authors:  Jay S Pepose; Mujtaba A Qazi; Keith H Edwards; Jeff P Sanderson; Edwin J Sarver
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-03-11       Impact factor: 3.117

3.  Bimanual microincisional cataract surgery technique and clinical outcome.

Authors:  Abdulrahman Al-Muammar
Journal:  Saudi J Ophthalmol       Date:  2009-08-05

4.  Custom optimization of intraocular lens asphericity.

Authors:  Douglas D Koch; Li Wang
Journal:  Trans Am Ophthalmol Soc       Date:  2007

Review 5.  [Aspheric intraocular lenses].

Authors:  T Kohnen; O K Klaproth
Journal:  Ophthalmologe       Date:  2008-03       Impact factor: 1.174

6.  Correlation between contrast sensitivity and higher-order aberration based on pupil diameter after cataract surgery.

Authors:  Takefumi Yamaguchi; Kazuno Negishi; Kazuhiko Ohnuma; Kazuo Tsubota
Journal:  Clin Ophthalmol       Date:  2011-12-07

7.  Aspheric versus Spherical Posterior Chamber Intraocular Lenses.

Authors:  Mohammad-Reza Jafarinasab; Sepehr Feizi; Ahmad-Reza Baghi; Hossein Ziaie; Mehdi Yaseri
Journal:  J Ophthalmic Vis Res       Date:  2010-10

8.  A comparative study on visual and optical performance of Akreos AO and Kontur AB IOLs after phacoemulsification cataract surgery.

Authors:  Hamid Gharaee; Masoud Zabihifard; Alireza Eslampour; Samira Hassanzadeh; Masoud Shafiee
Journal:  J Curr Ophthalmol       Date:  2016-03-28

9.  Aspheric intraocular lenses implantation for cataract patients with extreme myopia.

Authors:  Yanwen Fang; Yi Lu; Aizhu Miao; Yi Luo
Journal:  ISRN Ophthalmol       Date:  2014-03-19

Review 10.  Premium IOLs in Glaucoma.

Authors:  Parul Ichhpujani; Shibal Bhartiya; Anuj Sharma
Journal:  J Curr Glaucoma Pract       Date:  2013-05-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.