PURPOSE: To compare the effects of an aspheric intraocular lens (IOL) (Tecnis Z-9000, Pharmacia Corp.) with those of conventional silicone (AA4207VF, Staar Surgical) and acrylic (AcrySof SA60AT, Alcon Surgical) lenses on retinal imaging and functional visual performance.
SETTING: Eye Laser Center, Tucson, Arizona, USA.
METHODS: In this prospective study, 221 eyes of 156 patients were randomly assigned to receive 1 of 3 IOLs. Visual acuity was measured preoperatively and 1 day, 1 and 3 weeks, and 1, 3, and 6 months postoperatively. Fundus photography and photopic and mesopic functional acuity contrast testing were performed preoperatively and 3 months postoperatively.
RESULTS: The differences in the preoperative and postoperative spherical and astigmatic refractive errors and best corrected visual acuity among groups were not statistically significant. The postoperative uncorrected visual acuity was best in the aspheric group in the first month. Functional acuity contrast testing showed the aspheric IOL group had a 38% to 47% increase in photopic vision, 38% in photopic with glare, 43% to 100% in mesopic, and 9% to 100% in mesopic with glare. There was no increase in photopic vision in the acrylic group but increases of 38% in photopic with glare, 25% to 50% in mesopic, and 36% to 50% in mesopic with glare. The spherical silicone IOL group had no increase in contrast testing from preoperatively. Digital analysis of retinal imaging showed increased threshold luminance levels in the aspheric group (range 116 to 208 cd/m2) and a 4-fold increase in image contrast.
CONCLUSIONS: All 3 IOLs led to improved visual acuity after cataract surgery. The aspheric IOL provided a significant improvement in retinal image contrast and visual performance measured by visual acuity and functional acuity contrast testing. This improvement was greatest in night vision and night vision with glare compared to the performance of conventional spherical silicone and acrylic IOLs.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14522286     DOI: 10.1016/s0886-3350(03)00523-6

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  14 in total

1.  [Investigation of the theoretical image quality of aspheric intraocular lenses by decentration. Hoya AF-1 iMics1 und Zeiss ASPHINA(TM) (Invent ZO)].

Authors:  M Gillner; A Langenbucher; T Eppig
Journal:  Ophthalmologe       Date:  2012-03       Impact factor: 1.059

2.  Star testing: a novel evaluation of intraocular lens optical quality.

Authors:  L Mitchell; A C B Molteno; T H Bevin; G Sanderson
Journal:  Br J Ophthalmol       Date:  2006-05       Impact factor: 4.638

Review 3.  [Application of wavefront analysis in clinical and scientific settings. From irregular astigmatism to aberrations of a higher order--Part II: examples].

Authors:  J Bühren; T Kohnen
Journal:  Ophthalmologe       Date:  2007-11       Impact factor: 1.059

4.  Comparison of contrast sensitivity, depth of field and ocular wavefront aberrations in eyes with an IOL with zero versus positive spherical aberration.

Authors:  Jay S Pepose; Mujtaba A Qazi; Keith H Edwards; Jeff P Sanderson; Edwin J Sarver
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-03-11       Impact factor: 3.117

5.  [Accuracy of lens power calculation and centration of an aspheric intraocular lens].

Authors:  K A Becker; M P Holzer; A J Reuland; G U Auffarth
Journal:  Ophthalmologe       Date:  2006-10       Impact factor: 1.059

6.  Tilt and decentration of an intraocular lens implanted in the ciliary sulcus after capsular bag defect during cataract surgery.

Authors:  Thomas Sauer; Ulrich Mester
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-09-02       Impact factor: 3.117

Review 7.  [Aspheric intraocular lenses].

Authors:  T Kohnen; O K Klaproth
Journal:  Ophthalmologe       Date:  2008-03       Impact factor: 1.174

8.  Softec HD hydrophilic acrylic intraocular lens: biocompatibility and precision.

Authors:  Ladan Espandar; Shameema Sikder; Majid Moshirfar
Journal:  Clin Ophthalmol       Date:  2011-01-10

9.  Patient acceptability of the Tecnis multifocal intraocular lens.

Authors:  Priyanka Sood; Maria A Woodward
Journal:  Clin Ophthalmol       Date:  2011-03-24

10.  Visual performance of the Tecnis one-piece lens ZCB00.

Authors:  Sherein S Wahba; Riad F Riad; Fathy F Morkos; Abdallah K Hassouna; Maged M Roshdy
Journal:  Clin Ophthalmol       Date:  2011-12-23
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.