| Literature DB >> 32821488 |
Ye Zhang1, Qing Zhang2, Lei Li1, Ravi Thomas3,4, Si Zhen Li5, Ming Guang He6,7,8, Ning Li Wang1,2.
Abstract
Purpose: To establish and evaluate algorithms for detection of primary angle closure suspects (PACS), the risk factor for primary angle closure disease by combining multiple static and dynamic anterior segment optical coherence tomography (ASOCT) parameters.Entities:
Keywords: iris dynamic changes; machine-learning algorithms; primary angle closure suspect; screening
Mesh:
Year: 2020 PMID: 32821488 PMCID: PMC7401939 DOI: 10.1167/tvst.9.5.16
Source DB: PubMed Journal: Transl Vis Sci Technol ISSN: 2164-2591 Impact factor: 3.283
Demographic Data and Ocular Biometric Measurements in PACS and Normal Subjects
| Parameter | Normal Subjects (n = 339) | PACS Subjects (n = 405) |
|
|---|---|---|---|
| Age (IR), years | 61.0 (56.0, 66.0) | 62.0 (57.0, 67.0) | 0.119 |
| Male (%) | 121 (35.7) | 125 (30.9) | |
| 0.163 | |||
| Female (%) | 218 (64.3) | 280 (69.1) | |
| PVA (IR) | 0.20 (0.10–0.32) | 0.30 (0.12–0.44) | <.001 |
| BCVA (IR) | 0.00 (0.00–0.18) | 0.08 (0.00–0.20) | 0.025 |
| SE (IR), diopter | 0.50 (-0.25–1.13) | 0.81 (0.25–1.50) | <0.001 |
| IOP (IR), mm Hg | 12.0 (10.0–13.5) | 11.5 (10.0–13.0) | 0.086 |
| CCT (IR), mm | 528 (510–545) | 528 (514–548) | 0.282 |
| Central ACD (IR), mm | 2.71 (2.49–2.92) | 2.51 (2.33–2.76) | <0.001 |
| LT (IR), mm | 4.79 (4.51–5.07) | 4.86 (4.53–5.11) | 0.139 |
| AL (IR), mm | 22.73 (22.19–23.27) | 22.28 (21.81–22.97) | 0.001 |
ACD, anterior chamber depth; AL, axial length; BCVA, best corrected visual acuity; CCT, central corneal thickness; IOP, intraocular pressure; IR, interquartile range; LT, lens thickness; PVA, presenting visual acuity; SE, spherical equivalent.
Mann-Whitney U test.
χ2 test.
Anterior Chamber, Angle, Lens, and Iris Parameters Measured by ASOCT in Light and Dark Conditions in PACS and Normal Subjects
| Conditions | Parameter | Normal Subjects (n = 339) | PACS Subjects (n = 405) |
|
|---|---|---|---|---|
|
| AOD500 (IR), mm | 0.349 (0.286–0.448) | 0.249 (0.183–0.313) | <0.001 |
| TISA500 (IR), mm2 | 0.144 (0.120–0.181) | 0.103 (0.076–0.131) | <0.001 | |
| ARA (IR), mm2 | 0.406 (0.322–0.488) | 0.269 (0.193–0.345) | <0.001 | |
| ACD (IR), mm | 2.488 (2.321–2.639) | 0.245 (2.072–2.401) | <0.001 | |
| ACW (SD), mm | 11.10 (0.40) | 10.87 (0.42) | <0.001 | |
| ACA (IR), mm2 | 18.26 (16.60–19.81) | 15.85 (14.25–17.25) | <0.001 | |
| ACV (IR), mm3 | 73.61 (65.26–82.33) | 60.40 (53.41–68.18) | <0.001 | |
| IT750 (IR), mm | 0.44 (0.39–0.48) | 0.47 (0.43–0.50) | <0.001 | |
| IC (SD), mm | 0.24 (0.19–0.28) | 0.26 (0.21–0.31) | <0.001 | |
| LV (IR), mm | 252.3 (111.1–393.3) | 415.9 (287.2–516.5) | <0.001 | |
|
| AOD500 (IR), mm | 0.309 (0.252–0.388) | 0.211 (0.138–0.278) | <0.001 |
| TISA500 (IR), mm2 | 0.129 (0.105–0.156) | 0.084 (0.059–0.111) | <0.001 | |
| ARA (IR), mm2 | 0.329 (0.266–0.408) | 0.206 (0.142–0.278) | <0.001 | |
| ACD (IR), mm | 2.483 (2.327–2.633) | 2.251 (2.066–2.402) | <0.001 | |
| ACW (IR), mm | 11.08 (10.80–11.33) | 10.94 (10.69–11.19) | <0.001 | |
| ACA (IR), mm2 | 18.60 (16.96–20.25) | 16.24 (14.63–17.79) | <0.001 | |
| ACV (IR), mm3 | 74.47 (66.57–83.86) | 62.76 (54.23–70.95) | <0.001 | |
| IT750 (IR), mm | 0.47 (0.42–0.51) | 0.49 (0.46–0.53) | <0.001 | |
| IC (IR), mm | 0.24 (0.20–0.28) | 0.25 (0.21–0.30) | <0.001 | |
| LV (IR), mm | 276.4 (136.3–390.3) | 418.9 (303.5–558.1) | <0.001 |
ACA, anterior chamber area; ACD, anterior chamber depth; ACV, anterior chamber volume; ACW, anterior chamber width; AOD500, angle opening distance at 500 µm; ARA750, angle recess area at 750 µm; IC, iris curvature; IT750, iris thickness at 750 µm; IR, interquartile range; LV, lens vault; SD, standard deviation; TISA500, trabecular-iris space at 500 µm.
Mann-Whitney U test.
Two sample t-test.
ASOCT Data: IA, PD, IA Changes and IA Changes per PD Changes for PACS and Normal Subjects
| Parameter | Normal Subjects (n = 339) | PACS Subjects (n = 405) |
|
|---|---|---|---|
| IA; L (SD), mm2 | 2.94 (0.37) | 2.90 (0.39) | 0.155 |
| PD; L (SD), mm | 3.82 (0.64) | 3.90 (0.64) | 0.113 |
| IA; D (SD), mm2 | 2.69 (0.34) | 2.71 (0.37) | 0.383 |
| PD; D (IR), mm | 4.86 (4.25–5.28) | 4.81 (4.34–5.23) | 0.952 |
| IA Change; D (IR), mm2 | 0.25 (0.13–0.39) | 0.20 (0.03–0.35) | <0.001 |
| PD Change; D (IR), mm | 0.88 (0.61–1.18) | 0.74 (0.31–0.35) | 0.001 |
| IA Change / PD Change (IR), mm | 0.26 (0.16–0.36) | 0.22 (0.05–0.37) | 0.001 |
D, dark; IA, iris cross-sectional area; IR, interquartile range; L, light; PD, pupil diameter; SD, standard deviation.
Mann-Whitney U test.
Two sample t-test.
Variables Included in the Prediction Models Using Backward Logistic Regression
| Estimated Regression | Standard | ||||
|---|---|---|---|---|---|
| Parameter | Coefficient | Error |
|
| OR (95% CI) |
| ARA750 | -7.846 | 1.112 | 49.764 | <0.001 | <0.001 (<0.001–0.003) |
| ACV | -0.029 | 0.010 | 8.863 | 0.003 | 0.971 (0.953–0.990) |
| LV | 0.001 | 0.001 | 7.741 | 0.005 | 1.001 (1.000–1.003) |
| IA change/PD change | -1.014 | 0.353 | 8.272 | 0.004 | 0.363 (0.182–0.724) |
ACV, anterior chamber volume; ARA750, angle recess area at 750 µm; CI, confidence interval; IA, iris cross-sectional area; LV, lens vault; OR, odds ratio; PD, pupil diameter.
AUC, Sensitivity, and Specificity of Algorithms
| Prediction | 95% CI of | 95% CI of | 95% CI of | |||
|---|---|---|---|---|---|---|
| Algorithm | AUC | of AUC | Sensitivity | Sensitivity | Specificity | Specificity |
| Backward logistic Regression | 0.827 | 0.798–0.856 | 72.35% | 67.99–76.71 | 78.17% | 73.77–82.57 |
| Naïve Bayes’ classification | 0.826 | 0.797–0.854 | 72.84% | 68.51–77.17 | 76.40% | 71.88–80.92 |
| Neural network | 0.844 | 0.817–0.871 | 78.02% | 73.98–82.05 | 74.93% | 70.32–79.54 |
AUC, area under the receiver operator characteristic curve; CI, confidence interval.
FigureReceiver operating characteristic curves of three machine-learning algorithms