Jong Yoon Lee1, Myeongseok Koh1, Jong Hoon Lee2. 1. Department of Internal Medicine, Dong-A University College of Medicine, Busan, 49201, South Korea. 2. Department of Internal Medicine, Dong-A University College of Medicine, Busan, 49201, South Korea. leejonghoon2002@gmail.com.
Abstract
BACKGROUND: Adenoma detection rate (ADR) is an important quality indicator of colonoscopy. High-definition (HD) colonoscopy has been reported to increase ADR compared to standard-definition (SD) colonoscopy. Although there are few reports comparing the latest generation and the previous generation of HD colonoscopy equipment, there are reports that the latest generation colonoscopy equipment improves ADR. However, there are no reports on the impact of the latest generation HD colonoscopy on the ADR of trainee endoscopists. AIMS: The aim of this study was to investigate whether the latest generation HD colonoscopy increases the ADR of trainee endoscopists compared with the previous generation HD colonoscopy. METHOD: We conducted a retrospective review of medical records of patients aged 40-79 years old, who underwent screening or surveillance colonoscopy performed by nine gastroenterology fellows at Dong-A University Hospital from March 2019 to February 2020. We calculated the overall ratios of the ADR: the ADRs of the group using the older generation HD colonoscopy equipment and the group using the latest HD colonoscopy equipment. Polyp detection rate (PDR), sessile serrated polyp detection rate (SSPDR), and advanced neoplasia detection rate (ANDR) were calculated for each group. Factors related to adenoma detection were identified using logistic regression analysis. RESULTS: Altogether, 2189 patients were included in the study (the older HD colonoscopy group comprising 1183 and the latest HD colonoscopy group comprising 1006). We found that PDR (45.98 vs. 51.69%, p = 0.008) and ADR (35.67 vs. 40.85%, p = 0.013) were significantly higher in the latest generation HD colonoscopy group. The generational differences were not statistically significant for SSPDR (1.94 vs. 2.78%, p = 0.195) or ANDR (4.65 vs. 4.97%, p = 0.726). In the multivariate regression analysis, age, male sex, the latest generation HD colonoscopy, and long withdrawal time were the most significant factors affecting adenoma detection. CONCLUSIONS: The latest generation HD colonoscopy improved PDR and ADR by trainee endoscopists. These findings suggest that latest generation, higher-resolution colonoscopy equipment can improve the quality of colonoscopy for less experienced endoscopists.
BACKGROUND:Adenoma detection rate (ADR) is an important quality indicator of colonoscopy. High-definition (HD) colonoscopy has been reported to increase ADR compared to standard-definition (SD) colonoscopy. Although there are few reports comparing the latest generation and the previous generation of HD colonoscopy equipment, there are reports that the latest generation colonoscopy equipment improves ADR. However, there are no reports on the impact of the latest generation HD colonoscopy on the ADR of trainee endoscopists. AIMS: The aim of this study was to investigate whether the latest generation HD colonoscopy increases the ADR of trainee endoscopists compared with the previous generation HD colonoscopy. METHOD: We conducted a retrospective review of medical records of patients aged 40-79 years old, who underwent screening or surveillance colonoscopy performed by nine gastroenterology fellows at Dong-A University Hospital from March 2019 to February 2020. We calculated the overall ratios of the ADR: the ADRs of the group using the older generation HD colonoscopy equipment and the group using the latest HD colonoscopy equipment. Polyp detection rate (PDR), sessile serrated polyp detection rate (SSPDR), and advanced neoplasia detection rate (ANDR) were calculated for each group. Factors related to adenoma detection were identified using logistic regression analysis. RESULTS: Altogether, 2189 patients were included in the study (the older HD colonoscopy group comprising 1183 and the latest HD colonoscopy group comprising 1006). We found that PDR (45.98 vs. 51.69%, p = 0.008) and ADR (35.67 vs. 40.85%, p = 0.013) were significantly higher in the latest generation HD colonoscopy group. The generational differences were not statistically significant for SSPDR (1.94 vs. 2.78%, p = 0.195) or ANDR (4.65 vs. 4.97%, p = 0.726). In the multivariate regression analysis, age, male sex, the latest generation HD colonoscopy, and long withdrawal time were the most significant factors affecting adenoma detection. CONCLUSIONS: The latest generation HD colonoscopy improved PDR and ADR by trainee endoscopists. These findings suggest that latest generation, higher-resolution colonoscopy equipment can improve the quality of colonoscopy for less experienced endoscopists.
Authors: Philip Schoenfeld; Brooks Cash; Andrew Flood; Richard Dobhan; John Eastone; Walter Coyle; James W Kikendall; Hyungjin Myra Kim; David G Weiss; Theresa Emory; Arthur Schatzkin; David Lieberman Journal: N Engl J Med Date: 2005-05-19 Impact factor: 91.245
Authors: Ann G Zauber; Sidney J Winawer; Michael J O'Brien; Iris Lansdorp-Vogelaar; Marjolein van Ballegooijen; Benjamin F Hankey; Weiji Shi; John H Bond; Melvin Schapiro; Joel F Panish; Edward T Stewart; Jerome D Waye Journal: N Engl J Med Date: 2012-02-23 Impact factor: 91.245
Authors: Bernard Levin; David A Lieberman; Beth McFarland; Kimberly S Andrews; Durado Brooks; John Bond; Chiranjeev Dash; Francis M Giardiello; Seth Glick; David Johnson; C Daniel Johnson; Theodore R Levin; Perry J Pickhardt; Douglas K Rex; Robert A Smith; Alan Thorson; Sidney J Winawer Journal: Gastroenterology Date: 2008-02-08 Impact factor: 22.682
Authors: Douglas A Corley; Christopher D Jensen; Amy R Marks; Wei K Zhao; Jeffrey K Lee; Chyke A Doubeni; Ann G Zauber; Jolanda de Boer; Bruce H Fireman; Joanne E Schottinger; Virginia P Quinn; Nirupa R Ghai; Theodore R Levin; Charles P Quesenberry Journal: N Engl J Med Date: 2014-04-03 Impact factor: 91.245
Authors: S J Winawer; A G Zauber; M N Ho; M J O'Brien; L S Gottlieb; S S Sternberg; J D Waye; M Schapiro; J H Bond; J F Panish Journal: N Engl J Med Date: 1993-12-30 Impact factor: 91.245
Authors: Freddie Bray; Jacques Ferlay; Isabelle Soerjomataram; Rebecca L Siegel; Lindsey A Torre; Ahmedin Jemal Journal: CA Cancer J Clin Date: 2018-09-12 Impact factor: 508.702
Authors: Chyke A Doubeni; Douglas A Corley; Virginia P Quinn; Christopher D Jensen; Ann G Zauber; Michael Goodman; Jill R Johnson; Shivan J Mehta; Tracy A Becerra; Wei K Zhao; Joanne Schottinger; V Paul Doria-Rose; Theodore R Levin; Noel S Weiss; Robert H Fletcher Journal: Gut Date: 2016-10-12 Impact factor: 23.059
Authors: Cristiano Spada; Anastasios Koulaouzidis; Cesare Hassan; Pedro Amaro; Anurag Agrawal; Lene Brink; Wolfgang Fischbach; Matthias Hünger; Rodrigo Jover; Urpo Kinnunen; Akiko Ono; Árpád Patai; Silvia Pecere; Lucio Petruzziello; Jürgen Ferdinand Riemann; Harry Staines; Ann L Stringer; Ervin Toth; Giulio Antonelli; Lorenzo Fuccio Journal: Int J Environ Res Public Health Date: 2022-03-13 Impact factor: 3.390