Literature DB >> 32797862

Estimation of low-level components lost through chromatographic separations with finite detection limits.

Nicole M Devitt1, Joe M Davis2, Mark R Schure3.   

Abstract

The search for biomarkers allowing the assessment of disease by early diagnosis is facilitated by liquid chromatography. However, it is not clear how many components are lost due to being present in concentrations below the detection limit and/or being obscured by chromatographic peak overlap. First, we extend the study of missing components undertaken by Enke and Nagels, who employed the log-normal probability density function (pdf) for the distribution of signal intensities (and concentrations) of three mixtures. The Weibull and exponential pdfs, which have a higher probability of small-concentration components than the log-normal pdf, are also investigated. Results show that assessments of the loss of low-intensity signals by curve fitting are ambiguous. Next, we simulate synthetic chromatograms to compare the loss of peaks from superposition (overlap) with neighboring peaks to the loss arising from lying below the limit of detection (LOD) imposed by a finite signal-to-noise ratio (SNR). The simulations are made using amplitude pdfs based on the Enke-Nagels data as functions of relative column efficiency, i.e., saturation, and SNR. Results show that at the highest efficiencies, the lowest-amplitude peaks are lost below the LOD. However, at small and medium efficiencies, peak overlap is the dominant loss mechanism, suggesting that low-level components will not be found easily in liquid chromatography with single channel detectors regardless of SNR. A simple treatment shows that a multichannel detector, e.g., a mass spectrometer, is necessary to expose more low-level components.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biomarkers; Detection; Peak overlap; Trace analysis

Mesh:

Substances:

Year:  2020        PMID: 32797862      PMCID: PMC7748966          DOI: 10.1016/j.chroma.2020.461266

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  39 in total

Review 1.  Proteomics by FTICR mass spectrometry: top down and bottom up.

Authors:  Bogdan Bogdanov; Richard D Smith
Journal:  Mass Spectrom Rev       Date:  2005 Mar-Apr       Impact factor: 10.946

2.  Combination of abundant protein depletion and multi-lectin affinity chromatography (M-LAC) for plasma protein biomarker discovery.

Authors:  Tatiana Plavina; Eric Wakshull; William S Hancock; Marina Hincapie
Journal:  J Proteome Res       Date:  2007-02       Impact factor: 4.466

3.  Critical peak resolution in multicomponent chromatograms.

Authors:  A Felinger
Journal:  Anal Chem       Date:  1997-08-01       Impact factor: 6.986

4.  Depletion of abundant plasma proteins and limitations of plasma proteomics.

Authors:  Chengjian Tu; Paul A Rudnick; Misti Y Martinez; Kristin L Cheek; Stephen E Stein; Robbert J C Slebos; Daniel C Liebler
Journal:  J Proteome Res       Date:  2010-10-01       Impact factor: 4.466

5.  MS/MS spectra interpretation as a statistical-mechanics problem.

Authors:  Mauro Faccin; Pierpaolo Bruscolini
Journal:  Anal Chem       Date:  2013-04-29       Impact factor: 6.986

6.  Separation of one-pot procedure released O-glycans as 1-phenyl-3-methyl-5-pyrazolone derivatives by hydrophilic interaction and reversed-phase liquid chromatography followed by identification using electrospray mass spectrometry and tandem mass spectrometry.

Authors:  Chengjian Wang; Jiangbei Yuan; Zhongfu Wang; Linjuan Huang
Journal:  J Chromatogr A       Date:  2012-12-13       Impact factor: 4.759

7.  Experimentally Validating Open Tubular Liquid Chromatography for a Peak Capacity of 2000 in 3 h.

Authors:  Piliang Xiang; Yu Yang; Zhitao Zhao; Apeng Chen; Shaorong Liu
Journal:  Anal Chem       Date:  2019-07-31       Impact factor: 6.986

8.  Isomer-specific LC/MS and LC/MS/MS profiling of the mouse serum N-glycome revealing a number of novel sialylated N-glycans.

Authors:  Serenus Hua; Ha Neul Jeong; Lauren M Dimapasoc; Inae Kang; Chanyoung Han; Jong-Soon Choi; Carlito B Lebrilla; Hyun Joo An
Journal:  Anal Chem       Date:  2013-04-18       Impact factor: 6.986

9.  Glycoproteomic identification of potential glycoprotein biomarkers in ovarian cancer proximal fluids.

Authors:  Uros Kuzmanov; Natasha Musrap; Hari Kosanam; Christopher R Smith; Ihor Batruch; Apostolos Dimitromanolakis; Eleftherios P Diamandis
Journal:  Clin Chem Lab Med       Date:  2013-07       Impact factor: 3.694

10.  Comparison of different signal thresholds on data dependent sampling in Orbitrap and LTQ mass spectrometry for the identification of peptides and proteins in complex mixtures.

Authors:  Catherine C L Wong; Daniel Cociorva; John D Venable; Tao Xu; John R Yates
Journal:  J Am Soc Mass Spectrom       Date:  2009-04-18       Impact factor: 3.109

View more
  1 in total

1.  A comparison of 2 micron inner diameter open tubular column liquid chromatography with pressure-driven isocratic, slip-flow, and electrochromatographic modes of operation: a theoretical study.

Authors:  Mark R Schure; Matthew D Beauchamp
Journal:  J Chromatogr A       Date:  2020-12-24       Impact factor: 4.759

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.