Literature DB >> 32791979

COVID-19: efficacy of prehospital pulse oximetry for early detection of silent hypoxemia.

Valentina Quaresima1, Marco Ferrari2.   

Abstract

Entities:  

Mesh:

Year:  2020        PMID: 32791979      PMCID: PMC7424128          DOI: 10.1186/s13054-020-03185-x

Source DB:  PubMed          Journal:  Crit Care        ISSN: 1364-8535            Impact factor:   9.097


× No keyword cloud information.
We read with interest the research letter published in Critical Care by Jouffroy et al. who suggest the utility of prehospital pulse oximetry as a red flag for early detection of silent hypoxemia in COVID-19 patients [1]. Fingertip pulse oximeters are one of the most widely used medical standard monitoring tools to assess oxygenation and respiratory function in patients. In fact, a pulse oximeter noninvasively measures arterial blood oxygen saturation (SpO2, %), and it represents an accessible tool that can be easily used by patients, physicians, and prehospital healthcare providers. However, it is important to ensure that the used pulse oximeter has a high accuracy, especially when SpO2 is lower than 90%. The accuracy criteria for the pulse oximeter equipment are provided in the International Standard ISO 80601-2-61 [2], and the U.S. Food and Drug Administration (FDA) only permits pulse oximeters that meet these criteria [3]. According to the ISO 80601-2-61, the SpO2 accuracy of a pulse oximeter should be assessed through a controlled desaturation study by comparing the SpO2 measurements with the gold standard measurements of blood arterial oxygen saturation (SaO2) obtained by a CO-oximeter. The prices for home pulse oximeters range from $20 to $80, and not all pulse oximeters are built with the same performances and the required FDA’s accuracy. Few of them have the FDA’s approval. A recent study on the accuracy of six low-cost pulse oximeters, not cleared by the FDA, has demonstrated highly inaccurate readings, even if some of them surprisingly performed likewise the expensive clinical pulse oximeters during voluntary hypoxia [4]. Some COVID-19 patients suddenly develop the condition called “silent hypoxia,” during which they still look and feel comfortable, but their SpO2 is perilously low. This happens to patients either in the hospital or at home. Low SpO2 may indicate severe COVID-19-related pneumonia, requiring a ventilator. A useful practical guidance for the correct use of pulse oximetry for monitoring patients with COVID-19 at home have been very recently published [5]. SpO2 self-monitoring by patients with non-severe COVID-19, discharged from the emergency department or an outpatient testing center, is an essential way to identify patients needing to return to the hospital for a further evaluation. However, considering the largely unregulated low-cost pulse oximetry market, physicians should pay attention to incorporating SpO2 data, obtained from pulse oximeters not cleared [3] by the FDA, the European Medicine Agency or other regulatory agencies, for making medical decisions.

Authors’ response

Reply to Quaresima et al.: “COVID-19: efficacy of prehospital pulse oximetry for early detection of silent hypoxemia”

Romain Jouffroy, Daniel Jost, Bertrand Prunet Dear Editor, We thank Quaresima et al. [6] for their interest and relevant comments about the early detection of silent hypoxemia in COVID-19 patients based on prehospital pulse oximetry [1]. We agree that fingertip pulse oximeters may only provide approximate measurements of arterial blood oxygen saturation and that many intrinsic and extrinsic factors influence pulse oximetry values [6, 7] beyond the preanalytical conditions required for certification [8]. One particularity of COVID-19-related acute respiratory failure was that, despite low blood oxygen concentration, the respiratory rate frequently remained close to normal, unlike in other acute respiratory failure etiologies [9]. Our observational study was not designed to assess pulse oximetry for medical decision making but was intended to detect “silent hypoxemia” in suspected COVID-19 patients. Furthermore, the Paris Fire Brigade basic life support teams used a device complying with the European Union’s Medical Device Regulation of 2017. Quaresima et al. remind us that rescuers must continuously be aware of the technical limitations of the equipment they use in their daily practice.
  6 in total

Review 1.  Transcutaneous oxygen measurements: implications for nursing.

Authors:  K Rich
Journal:  J Vasc Nurs       Date:  2001-06

Review 2.  Pre-analytical processes in medical diagnostics: New regulatory requirements and standards.

Authors:  Georges Dagher; Karl-Friedrich Becker; Serena Bonin; Carole Foy; Stefania Gelmini; Mikael Kubista; Penelope Kungl; Uwe Oelmueller; Helen Parkes; Pamela Pinzani; Peter Riegman; Ulrike Schröder; Cornelia Stumptner; Paola Turano; Robert Sjöback; Andrea Wutte; Kurt Zatloukal
Journal:  N Biotechnol       Date:  2019-05-15       Impact factor: 5.079

Review 3.  The regulation of normal lung function.

Authors:  S S Braman
Journal:  Allergy Proc       Date:  1995 Sep-Oct

4.  The Accuracy of 6 Inexpensive Pulse Oximeters Not Cleared by the Food and Drug Administration: The Possible Global Public Health Implications.

Authors:  Michael S Lipnick; John R Feiner; Paul Au; Michael Bernstein; Philip E Bickler
Journal:  Anesth Analg       Date:  2016-08       Impact factor: 5.108

Review 5.  Pulse Oximetry for Monitoring Patients with COVID-19 at Home. Potential Pitfalls and Practical Guidance.

Authors:  Andrew M Luks; Erik R Swenson
Journal:  Ann Am Thorac Soc       Date:  2020-09

6.  Prehospital pulse oximetry: a red flag for early detection of silent hypoxemia in COVID-19 patients.

Authors:  Romain Jouffroy; Daniel Jost; Bertrand Prunet
Journal:  Crit Care       Date:  2020-06-08       Impact factor: 9.097

  6 in total
  5 in total

1.  Risk factors associated with hospital transfer among mild or asymptomatic COVID-19 patients in isolation facilities in Tokyo: a case-control study.

Authors:  Keisuke Naito; Tomoyo Narita; Yukari Murata; Naoto Morimura
Journal:  IJID Reg       Date:  2021-11-17

2.  Is Methadone Safe for Patients With Opioid Use Disorder and Coronavirus Disease 2019 Infection?

Authors:  John Arianda Owiti; Molli Benson; Mandisa Maplanka; Lasekan Oluseye; Debora Carvalho
Journal:  J Addict Nurs       Date:  2022 Apr-Jun 01       Impact factor: 0.971

3.  Digital oximetry biomarkers for assessing respiratory function: standards of measurement, physiological interpretation, and clinical use.

Authors:  Jeremy Levy; Daniel Álvarez; Aviv A Rosenberg; Alexandra Alexandrovich; Félix Del Campo; Joachim A Behar
Journal:  NPJ Digit Med       Date:  2021-01-04

Review 4.  Silent hypoxia in COVID-19: pathomechanism and possible management strategy.

Authors:  Ahsab Rahman; Tahani Tabassum; Yusha Araf; Abdullah Al Nahid; Md Asad Ullah; Mohammad Jakir Hosen
Journal:  Mol Biol Rep       Date:  2021-04-23       Impact factor: 2.316

5.  COVID-19 Prediction With Machine Learning Technique From Extracted Features of Photoplethysmogram Morphology.

Authors:  Nazrul Anuar Nayan; Choon Jie Yi; Mohd Zubir Suboh; Nur-Fadhilah Mazlan; Petrick Periyasamy; Muhammad Yusuf Zawir Abdul Rahim; Shamsul Azhar Shah
Journal:  Front Public Health       Date:  2022-07-19
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.