Doppler echocardiographic assessment of the effect of varying atrioventricular delay and pacemaker mode on left ventricular filling.

A C Pearson1, D L Janosik, R R Redd, T A Buckingham, R I Blum, A J Labovitz.   

Abstract

Pulsed Doppler echocardiography was used to study the timing and dynamics of left ventricular filling in 14 patients with permanent dual-chamber programmable pacemakers. Pacemakers were programmed to atrial sensed (VDD) mode and atrial-ventricular sequential paced mode at low (DVI-L) and high (DVI-H) heart rates, and pulsed Doppler recordings of transmitral flow were analyzed at atrioventricular delays of 50 to 300 msec in each mode. There was a significant decrease in the one-third filling fraction in both VDD and DVI-L modes and a significant increase in DVI-H modes with increasing atrioventricular delay. The ratio of early filling area to atrial filling area was significantly lower at longer atrioventricular delays in both VDD and DVI-L modes. The time from pacemaker spike to mitral valve closure was highly significantly correlated with atrioventricular delay in VDD, DVI-L, and DVI-H modes (r = -0.92, p = 0.0001; r = -0.90, p = 0.0001; and r = -0.85, p = 0.0001, respectively) as was the diastolic filling time to a lesser extent (r = -0.73, p = 0.0001; r = -0.69, p = 0.0001; r = -0.61, p = 0.0001, respectively). Events reflecting atrial systole occurred at a later time in the cardiac cycle in the atrial paced vs the atrial sensed mode. Thus changes in atrioventricular delay and pacemaker mode in this group of patients are a strong determinant of the timing and dynamics of left ventricular filling.

Entities:  

Mesh:

Year:  1988        PMID: 3278577     DOI: 10.1016/0002-8703(88)90812-5

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  5 in total

1.  The search for optimal atrioventricular interval.

Authors:  I Eli Ovsyshcher
Journal:  J Interv Card Electrophysiol       Date:  2005-11       Impact factor: 1.900

2.  Programming an optimal atrioventricular interval in a dual chamber pacemaker regional population.

Authors:  Cristian Statescu; Radu A Sascau; Vasile Maciuc; Catalina Arsenescu Georgescu
Journal:  Maedica (Buchar)       Date:  2011-10

3.  Relative effects of left ventricular mass and conduction disturbance on activation in patients with pathological left ventricular hypertrophy.

Authors:  H B Xiao; S J Brecker; D G Gibson
Journal:  Br Heart J       Date:  1994-06

4.  Influence of atrioventricular optimization on hemodynamic parameters and quality of life in patients with dual chamber pacemaker with ventricular lead in right ventricular outflow tract.

Authors:  Artur Klimczak; Adam S Budzikowski; Marcin Rosiak; Marzenna Zielińska; Bożena Urbanek; Karol Bartczak; Michał Chudzik; Jerzy K Wranicz
Journal:  Ann Noninvasive Electrocardiol       Date:  2014-03-06       Impact factor: 1.468

5.  Feasibility of a novel atrioventricular delay optimization method using transmitral and pulmonary venous flow in patients with sequential ventricular pacing or cardiac resynchronization therapy.

Authors:  Kenzo Fukuhara; Hiroyuki Okura; Terumasa Koyama; Teruyoshi Kume; Yoji Neishi; Akihiro Hayashida; Kiyoshi Yoshida
Journal:  J Echocardiogr       Date:  2014-12-19
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.