Literature DB >> 32783637

In vivo three-dimensional mandibular kinematics and functional point trajectories during temporomandibular activities using 3d fluoroscopy.

Chien-Chih Chen1,2,3,4, Cheng-Chung Lin5, Hong-Po Hsieh6, Yang-Chieh Fu6, Yunn-Jy Chen1, Tung-Wu Lu6,7.   

Abstract

OBJECTIVES: To measure in vivo three-dimensional kinematics of the mandible and associated end-point trajectories and to quantify their relationships during temporomandibular joint activities using 3D fluoroscopy.
METHODS: A novel fluoroscopy-based 3D measurement method was used to measure motions of the mandible and the associated end points (i.e. incisors and lateral poles of both condyles) during open close, lateral gliding and protrusion-retraction movements in healthy young individuals. The contributions of each of the rotational and translational components of the mandible to the end-point trajectories were quantified through experiment-based computer simulations.
RESULTS: The mandibular rotation was found to account for 91% of the maximal mouth-opening-capacity and 73% of the maximal lateral incisor movement, while the condylar translation contributed to 99% of the anterior protrusion distance. Incisor trajectories were nearly vertical within the first 60% of the maximal opening during the open-close movement.
CONCLUSIONS: Similar condylar downward rotation paths but with bilaterally asymmetrical ranges were used to perform basic mandibular movements of different targeted TI trajectories in three dimensions, that is, open-close, lateral-gliding and protrusion-retraction. Mandibular rotations contributed to the majority of the principal displacement components of the incisor, that is, vertical during open-close and towards the working-side-during lateral-gliding, while mandibular translation contributed mainly to the forward movement of the incisor during protrusion-retraction. Owing to the anatomical constraints, the freedom of mandibular translation is limited and mainly in the anteroposterior direction, which is considered helpful for the control and stability of the TMJ during oral activities.

Entities:  

Keywords:  3D fluoroscopy; functional activities; incisor trajectories; mandibular kinematics; temporomandibular joint

Mesh:

Year:  2020        PMID: 32783637      PMCID: PMC7860955          DOI: 10.1259/dmfr.20190464

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  58 in total

1.  Maximum jaw opening capacity in adolescents in relation to general joint mobility.

Authors:  L Westling; E Helkimo
Journal:  J Oral Rehabil       Date:  1992-09       Impact factor: 3.837

2.  A volumetric model-based 2D to 3D registration method for measuring kinematics of natural knees with single-plane fluoroscopy.

Authors:  Tsung-Yuan Tsai; Tung-Wu Lu; Chung-Ming Chen; Mei-Ying Kuo; Horng-Chaung Hsu
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

3.  Associations between incisor and mandibular condylar movements during maximum mouth opening in humans.

Authors:  K H Travers; P H Buschang; H Hayasaki; G S Throckmorton
Journal:  Arch Oral Biol       Date:  2000-04       Impact factor: 2.633

4.  Effective dose from cone beam CT examinations in dentistry.

Authors:  J A Roberts; N A Drage; J Davies; D W Thomas
Journal:  Br J Radiol       Date:  2008-10-13       Impact factor: 3.039

5.  Characteristics of protrusive and lateral excursions of the mandible in children with the primary dentition.

Authors:  H Hayasaki; Y Yamasaki; N Nishijima; K Naruse; M Nakata
Journal:  J Oral Rehabil       Date:  1998-04       Impact factor: 3.837

6.  Description of mandibular finite helical axis pathways in asymptomatic subjects.

Authors:  L M Gallo; G B Airoldi; R L Airoldi; S Palla
Journal:  J Dent Res       Date:  1997-02       Impact factor: 6.116

7.  Three-dimensional mandibular motion in skeletal Class III patients.

Authors:  Alessandro Ugolini; Andrea Mapelli; Marzia Segù; Matteo Zago; Marina Codari; Chiarella Sforza
Journal:  Cranio       Date:  2017-03-17       Impact factor: 2.020

8.  OKAS-3D: optoelectronic jaw movement recording system with six degrees of freedom.

Authors:  M Naeije; J J Van der Weijden; C C Megens
Journal:  Med Biol Eng Comput       Date:  1995-09       Impact factor: 2.602

9.  Kinesiographic three-dimensional evaluation of mandibular border movements: a statistical study in a normal young nonpatient group.

Authors:  V F Ferrario; C Sforza; A Miani; G Serrao
Journal:  J Prosthet Dent       Date:  1992-10       Impact factor: 3.426

10.  A model relating patterns of human jaw movement to biomechanical constraints.

Authors:  F A Baragar; J W Osborn
Journal:  J Biomech       Date:  1984       Impact factor: 2.712

View more
  1 in total

Review 1.  Efficacy of Kinematic Parameters for Assessment of Temporomandibular Joint Function and Disfunction: A Systematic Review and Meta-Analysis.

Authors:  Alessandra Scolaro; Shahnawaz Khijmatgar; Pooja Mali Rai; Francesca Falsarone; Francesca Alicchio; Arianna Mosca; Christian Greco; Massimo Del Fabbro; Gianluca Martino Tartaglia
Journal:  Bioengineering (Basel)       Date:  2022-06-22
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.