Abstract

In medical ultrasound imaging, lateral resolution is limited when using a fixed transmit focusing. Various synthetic aperture (SA) techniques, in which two-way dynamic focusing is enabled by utilizing prebeamformed radio-frequency (RF) data have been proposed for improving the spatial resolution. However, SA methods were not extensively evaluated in terms of their clinical performance. In this paper, a phantom and an in vivo evaluation of the SA method with bidirectional pixel-based focusing (BiPBF) is presented in comparison with the conventional beamforming. The performance of the proposed SA-BiPBF was assessed with a blind study and the established breast imaging-reporting and data system (BI-RADS), in addition to measuring contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR). Prebeamformed RF data were acquired from a tissue mimicking phantom (Model 040, CIRS Inc., Norfolk, VA, USA) and from patients with breast lesions by using a commercial ultrasound scanning system with a linear array transducer equipped with a research package and parallel data acquisition system (SonixTouch, SonixDAQ, and L14-5/38, Ultrasonix Corp., Canada). In phantom and in vivo experiments, a default setting of a breast preset was applied (e.g., the center frequency of 10 MHz and acoustic output of MI = 0.66). In phantom experiment, the SA-BiPBF method showed higher CNR and SNR values compared to the conventional method (3.4 and 23.9 dB versus 3.1 and 15.8 dB, respectively). In addition, the lateral resolution and penetration depth were increased by 95.4% and 40.3%, respectively. Consistent with the phantom experiment, in the in vivo experiment with ten patients, the CNR value for the SA method was 3.3 ± 0.5 compared to 2.8 ± 0.8 for the conventional method. Similarly, the SNR values with the SA-BiPBF and conventional methods were 34.0 ± 3.6 and 27.2 ± 3.4 dB, respectively. From the experiments, it was shown in side-by-side comparisons that the image quality of the SA-BiPBF method was considerably improved in both phantom and in vivo breast images. However, the SA-BiPBF image showed different features compared to the conventional one in the in vivo experiments. These features are resulting from the increased image quality of the SA-BiPBF method but are not always perceived as improvements by the radiologists.

Entities:  

Mesh:

Year:  2013        PMID: 23686939     DOI: 10.1109/TBME.2013.2263310

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  9 in total

1.  Improving beamforming performance by phased synthetic aperture imaging in medical ultrasound.

Authors:  Masume Sadeghi; Ali Mahloojifar
Journal:  J Med Ultrason (2001)       Date:  2016-10-28       Impact factor: 1.314

2.  Parallel Receive Beamforming Improves the Performance of Focused Transmit-Based Single-Track Location Shear Wave Elastography.

Authors:  Rifat Ahmed; Marvin M Doyley
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-06-01       Impact factor: 2.725

3.  Intravascular Ultrasound Imaging With Virtual Source Synthetic Aperture Focusing and Coherence Factor Weighting.

Authors:  Mingyue Yu; Yang Li; Teng Ma; K Kirk Shung; Qifa Zhou
Journal:  IEEE Trans Med Imaging       Date:  2017-07-04       Impact factor: 10.048

4.  Elevational Synthetic Aperture Focusing for Three-Dimensional Photoacoustic Imaging Using a Clinical One-Dimensional Array Transducer.

Authors:  Changhan Yoon; Jeeun Kang; Tai-Kyong Song; Jin Ho Chang
Journal:  IEEE Trans Biomed Eng       Date:  2022-08-19       Impact factor: 4.756

5.  A novel design framework of synthetic radial aperture focusing for volumetric transrectal ultrasound imaging.

Authors:  Hyunwoo Song; Jeeun Kang; Emad M Boctor
Journal:  J Comput Des Eng       Date:  2022-08-24

6.  Quest for the Vulnerable Atheroma: Carotid Stenosis and Diametric Strain--A Feasibility Study.

Authors:  Canxing Xu; Chun Yuan; Edward Stutzman; Gador Canton; Keith A Comess; Kirk W Beach
Journal:  Ultrasound Med Biol       Date:  2015-12-23       Impact factor: 2.998

7.  Sub-wavelength lateral detection of tissue-approximating masses using an ultrasonic metamaterial lens.

Authors:  Ezekiel L Walker; Yuqi Jin; Delfino Reyes; Arup Neogi
Journal:  Nat Commun       Date:  2020-11-24       Impact factor: 14.919

8.  In Vivo Evaluation of Plane Wave Imaging for Abdominal Ultrasonography.

Authors:  Sua Bae; Jintae Jang; Moon Hyung Choi; Tai-Kyong Song
Journal:  Sensors (Basel)       Date:  2020-10-05       Impact factor: 3.576

9.  Synthetic Aperture Imaging Using High-Frequency Convex Array for Ophthalmic Ultrasound Applications.

Authors:  Hae Gyun Lim; Hyung Ham Kim; Changhan Yoon
Journal:  Sensors (Basel)       Date:  2021-03-24       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.