Literature DB >> 31470944

Comparative meta-analysis of toric intraocular lens alignment accuracy in cataract patients: Image-guided system versus manual marking.

Fengqi Zhou1, Wu Jiang2, Zhuoling Lin3, Xiaoyan Li3, Jing Li3, Haotian Lin3, Weirong Chen3, Qiwei Wang4.   

Abstract

This meta-analysis studied toric intraocular lens (IOL) alignment accuracy using image-guided and manual marking methods by comparing the axis misalignment of toric IOLs, percentage of eyes with toric IOL axis misalignment within ±5 degrees, postoperative astigmatism, difference vector, and postoperative uncorrected distance visual acuity. The methodological quality was assessed using the modified Quality Assessment of Diagnostic Accuracy Studies-2 tool. Continuous variables were analyzed using weighted mean differences, and dichotomous variables were compared using the odds ratio. Five studies comprising a total of 257 eyes were analyzed. For heterogeneity, neither sensitivity analysis nor the Egger test detected statistical findings. The image-guided marking group had smaller toric IOL axis misalignment (P < .00001), less postoperative astigmatism (P = .003), and a smaller difference vector (P < .00001) than the manual marking group. The overall evidence from the studies indicates that image-guided marking is better than manual marking, resulting in less axis misalignment, a smaller difference vector, and less postoperative astigmatism.
Copyright © 2019 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Year:  2019        PMID: 31470944     DOI: 10.1016/j.jcrs.2019.03.030

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  10 in total

1.  Clinical outcomes of Ankoris toric intraocular lens implantation using a computer-assisted marker system.

Authors:  Biana Dubinsky-Pertzov; Idan Hecht; Inbal Gazit; Lior Or; Ori Mahler; Shlomo Rotman; Eran Pras; Adi Einan-Lifshitz
Journal:  Int Ophthalmol       Date:  2020-07-27       Impact factor: 2.031

2.  Comparison of the Orientation of the Corneal Steep Meridian Determined by Image-Guided System and Manual Method in the Same Eye.

Authors:  Tsutomu Ohashi; Takashi Kojima
Journal:  Clin Ophthalmol       Date:  2020-12-01

3.  Long-term outcomes of cataract surgery with toric intraocular lens implantation by the type of preoperative astigmatism.

Authors:  Tetsuro Oshika; Shinichiro Nakano; Yoshifumi Fujita; Yuya Nomura; Yasushi Inoue; Hiroyasu Takehara; Kazunori Miyata; Masato Honbou; Toru Sugita; Tsutomu Kaneko
Journal:  Sci Rep       Date:  2022-05-19       Impact factor: 4.996

4.  Outcomes of toric IOL implantation guided by iris-registered femtosecond laser capsulotomy markings.

Authors:  Bradley P O'Neill; Vasilios F Diakonis; Konstantinos T Tsaousis; Robert J Weinstock
Journal:  Int Ophthalmol       Date:  2021-07-27       Impact factor: 2.031

5.  Rotational stability of modified toric intraocular lens.

Authors:  Ryoko Osawa; Tetsuro Oshika; Masahiko Sano; Takuma Yuguchi; Tadayoshi Kaiya
Journal:  PLoS One       Date:  2021-03-01       Impact factor: 3.240

6.  Long-term changes in the refractive effect of a toric intraocular lens on astigmatism correction.

Authors:  Ken Hayashi; Motoaki Yoshida; Shunsuke Hayashi; Akira Hirata
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-09-08       Impact factor: 3.117

Review 7.  A Review of Smartphone Apps Used for Toric Intraocular Lens Calculation and Alignment.

Authors:  Yarrow Scantling-Birch; Hasan Naveed; Ritika Mukhija; Mayank A Nanavaty
Journal:  Vision (Basel)       Date:  2022-02-18

8.  Comparing IOLM700 TK, Berdahl and Hardten astigmatism fix calculator and Barrett Rx formula in managing residual astigmatism due to toric intraocular lens misalignment.

Authors:  Ajay C Sharma; Avani Khetan
Journal:  Indian J Ophthalmol       Date:  2022-02       Impact factor: 1.848

9.  Comparison of Visual Outcomes Between Toric Intraocular Lenses and Clear Corneal Incisions to Correct Astigmatism in Image-Guided Cataract Surgery.

Authors:  Ning Ding; Xudong Song; Xiaozhen Wang; Wenbin Wei
Journal:  Front Med (Lausanne)       Date:  2022-04-04

10.  Digital versus slit-beam marking for toric intraocular lenses in cataract surgery.

Authors:  Ning Ding; Xiaozhen Wang; Xudong Song
Journal:  BMC Ophthalmol       Date:  2022-07-27       Impact factor: 2.086

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.