Literature DB >> 32715378

An initial investigation of a wireless patient radiation dosimeter for use in interventional radiology.

Yohei Inaba1,2, Koichi Chida3,4, Yuuki Murabayashi1, Mime Endo1, Kazuki Otomo1, Masayuki Zuguchi1.   

Abstract

Radiation exposure during interventional radiology (IR) procedures is a critical issue. We have developed a wireless real-time dosimeter for IR patients that use nontoxic phosphor (four sensors). We evaluated the basic performance parameters (such as dose linearity, batch uniformity, reproducibility, and wireless-communication conditions) of the developed system using an IR X-ray system. Further, we investigated the influence of noise from other medical equipment on our wireless real-time dosimeter in the IR X-ray room. Overall, our wireless system exhibited excellent performance in terms of uniformity, reproducibility, and linearity; moreover, the wireless communication performance was better. The developed system enabled real-time visualization of patient radiation dose, without noise contamination from other medical equipment. In addition, the wireless system can be easily installed in a location where the PC screen (display) can be readily viewed by the IR physician. Hence, we developed a wireless system that can display the patient radiation dose data in real time; the system performed satisfactorily upon application in radiation dosimetry. Therefore, our wireless system will facilitate the real-time monitoring/management of patient radiation dose during IR.

Entities:  

Keywords:  Dosimetry; Fluoroscopy; Interventional radiology (IR); Radiation dose; Radiation protection; Radiation safety

Mesh:

Year:  2020        PMID: 32715378     DOI: 10.1007/s12194-020-00575-2

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  6 in total

1.  Evaluation of novel X-ray protective eyewear in reducing the eye dose to interventional radiology physicians.

Authors:  Mime Endo; Yoshihiro Haga; Masahiro Sota; Akiko Tanaka; Kazuki Otomo; Yuuki Murabayashi; Mitsuya Abe; Yuji Kaga; Yohei Inaba; Msatoshi Suzuki; Taiichiro Meguro; Koichi Chida
Journal:  J Radiat Res       Date:  2021-05-12       Impact factor: 2.724

Review 2.  What are useful methods to reduce occupational radiation exposure among radiological medical workers, especially for interventional radiology personnel?

Authors:  Koichi Chida
Journal:  Radiol Phys Technol       Date:  2022-05-24

3.  Lens dose reduction with a bismuth shield in neuro cone-beam computed tomography: an investigation on optimum shield device placement conditions.

Authors:  Satoru Kawauchi; Koichi Chida; Yusuke Hamada; Wataro Tsuruta
Journal:  Radiol Phys Technol       Date:  2021-11-18

4.  Radiation Eye Dose for Physicians in CT Fluoroscopy-Guided Biopsy.

Authors:  Yohei Inaba; Shin Hitachi; Munenori Watanuki; Koichi Chida
Journal:  Tomography       Date:  2022-02-08

5.  Occupational eye dose correlation with neck dose and patient-related quantities in interventional cardiology procedures.

Authors:  Hiroki Ishii; Koichi Chida; Ko Satsurai; Yoshihiro Haga; Yuji Kaga; Mitsuya Abe; Yohei Inaba; Masayuki Zuguchi
Journal:  Radiol Phys Technol       Date:  2022-01-23

6.  Development of a New Radiation Shield for the Face and Neck of IVR Physicians.

Authors:  Toshimitsu Sato; Yoichi Eguchi; Chika Yamazaki; Takanobu Hino; Toshikazu Saida; Koichi Chida
Journal:  Bioengineering (Basel)       Date:  2022-07-29
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.