Literature DB >> 32667115

Fast quantitative three-dimensional ultrashort echo time (UTE) Cones magnetic resonance imaging of major tissues in the knee joint using extended sprial sampling.

Lidi Wan1,2, Yajun Ma2, Jiawei Yang1, Saeed Jerban2, Adam C Searleman2, Michael Carl3, Nicole Le4, Eric Y Chang2,4, Guangyu Tang1, Jiang Du2.   

Abstract

The purpose of this study is to investigate the effect of extending the spiral sampling window on quantitative 3D ultrashort echo time (UTE) Cones imaging of major knee joint tissues including articular cartilage, menisci, tendons and ligaments at 3 T. Nine cadaveric human whole knee specimens were imaged on a 3 T clinical MRI scanner. A series of quantitative 3D UTE Cones imaging biomarkers including T2 *, T1 , adiabatic T1ρ , magnetization transfer ratio (MTR) and macromolecular fraction (MMF) were estimated using spiral sampling trajectories with various durations. Errors in UTE MRI biomarkers as a function of sampling time were evaluated using a nonstretched spiral trajectory as a reference standard. No significant differences were observed by increasing the spiral sampling window from 1116 to 2232 μs in the calculated T2 *, T1 , adiabatic T1ρ , MTR and MMF, as all P-values were over .05 as assessed by ANOVA with two-sided Dunnett's test. Although extending the sampling window results in signal loss for short T2 components, there was limited effect on the calculated quantitative biomarkers, with error percentages typically smaller than 5% in all the evaluated tissues. The total scan time can be reduced by up to 54% with quantification errors of less than 5% in any evaluated major tissue in the knee joint, suggesting that 3D UTE Cones MRI techniques can be greatly accelerated by using a longer spiral sampling window without causing additional quantitative bias.
© 2020 John Wiley & Sons, Ltd.

Entities:  

Keywords:  Sampling Window; UTE imaging; knee joint; major tissues; quantitative

Year:  2020        PMID: 32667115      PMCID: PMC7952018          DOI: 10.1002/nbm.4376

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  27 in total

Review 1.  Magnetic resonance: an introduction to ultrashort TE (UTE) imaging.

Authors:  Matthew D Robson; Peter D Gatehouse; Mark Bydder; Graeme M Bydder
Journal:  J Comput Assist Tomogr       Date:  2003 Nov-Dec       Impact factor: 1.826

2.  Accurate T1 mapping of short T2 tissues using a three-dimensional ultrashort echo time cones actual flip angle imaging-variable repetition time (3D UTE-Cones AFI-VTR) method.

Authors:  Ya-Jun Ma; Xing Lu; Michael Carl; Yanchun Zhu; Nikolaus M Szeverenyi; Graeme M Bydder; Eric Y Chang; Jiang Du
Journal:  Magn Reson Med       Date:  2018-01-03       Impact factor: 4.668

3.  Twisting radial lines with application to robust magnetic resonance imaging of irregular flow.

Authors:  J I Jackson; D G Nishimura; A Macovski
Journal:  Magn Reson Med       Date:  1992-05       Impact factor: 4.668

4.  Design and analysis of a practical 3D cones trajectory.

Authors:  Paul T Gurney; Brian A Hargreaves; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2006-03       Impact factor: 4.668

5.  Yet more evidence that osteoarthritis is not a cartilage disease.

Authors:  K D Brandt; E L Radin; P A Dieppe; L van de Putte
Journal:  Ann Rheum Dis       Date:  2006-10       Impact factor: 19.103

6.  Steady-state magnetizations in rapid NMR imaging using small flip angles and short repetition intervals.

Authors:  K Sekihara
Journal:  IEEE Trans Med Imaging       Date:  1987       Impact factor: 10.048

7.  Magnetization transfer contrast imaging in bovine and human cortical bone applying an ultrashort echo time sequence at 3 Tesla.

Authors:  Fabian Springer; Petros Martirosian; Jürgen Machann; Nina F Schwenzer; Claus D Claussen; Fritz Schick
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

8.  Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo.

Authors:  S D Wolff; R S Balaban
Journal:  Magn Reson Med       Date:  1989-04       Impact factor: 4.668

9.  UTE imaging with simultaneous water and fat signal suppression using a time-efficient multispoke inversion recovery pulse sequence.

Authors:  Michael Carl; Graeme M Bydder; Jiang Du
Journal:  Magn Reson Med       Date:  2015-08-26       Impact factor: 4.668

10.  Three-dimensional late gadolinium-enhanced MR imaging of the left atrium: a comparison of spiral versus Cartesian k-space trajectories.

Authors:  Benjamin R Knowles; Dana C Peters; Rachel E Clough; Reza Razavi; Tobias Schaeffter; Claudia Prieto
Journal:  J Magn Reson Imaging       Date:  2013-09-04       Impact factor: 4.813

View more
  3 in total

1.  On the fat saturation effect in quantitative ultrashort TE MR imaging.

Authors:  Yanjun Chen; Liang Li; Nicole Le; Eric Y Chang; Wenhua Huang; Ya-Jun Ma
Journal:  Magn Reson Med       Date:  2022-01-05       Impact factor: 3.737

Review 2.  Articular Cartilage Assessment Using Ultrashort Echo Time MRI: A Review.

Authors:  Amir Masoud Afsahi; Sam Sedaghat; Dina Moazamian; Ghazaleh Afsahi; Jiyo S Athertya; Hyungseok Jang; Ya-Jun Ma
Journal:  Front Endocrinol (Lausanne)       Date:  2022-05-26       Impact factor: 6.055

3.  Macromolecular fraction (MMF) from 3D ultrashort echo time cones magnetization transfer (3D UTE-Cones-MT) imaging predicts meniscal degeneration and knee osteoarthritis.

Authors:  X Zhang; Y-J Ma; Z Wei; M Wu; A Ashir; S Jerban; S Li; E Y Chang; J Du
Journal:  Osteoarthritis Cartilage       Date:  2021-04-18       Impact factor: 6.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.