Literature DB >> 18542960

Required time delay from 99mTc-HMPAO injection to SPECT data acquisition: healthy subjects and patients with rCBF pattern.

Gerda Thomsen1, Robin de Nijs, Esben Hogh-Rasmussen, Vibe Frokjaer, Claus Svarer, Gitte M Knudsen.   

Abstract

PURPOSE: Functional brain (99m)Tc-HMPAO single-photon emission computed tomography (SPECT) is a useful diagnostic tool for assessment of regional cerebral blood flow, particularly in dementia, cerebrovascular disease and epilepsy. Currently, the European and American Association of Nuclear Medicine Procedure Guidelines for Brain Perfusion SPET using (99m)Tc-labeled Radiopharmaceuticals recommend a time delay of 90 min between injection of (99m)Tc-HMPAO and data acquisition. This time delay is difficult to comply within the daily routine and present a problem, particularly with the elderly or demented patients. This study investigates in patients with perfusion deficits and in healthy subjects if the quality of the SPECT image is affected by lowering the time delay between (99m)Tc-HMPAO injection and data acquisition to 30 or 60 min.
METHODS: Thirty-seven healthy subjects (17 females; mean age 65; range 42-84 years) with normal cerebral blood flow distribution and 31 patients (17 females; mean age 67; range 38-84) with reduced rCBF distribution were included. Images were obtained with a three-headed Philips IRIX SPECT scanner with high-resolution collimators. The healthy subjects were scanned 30, 60 and 90 min after (99m)Tc-HMPAO injection, and the patients were scanned 30 and 90 or 60 and 90 min after (99m)Tc-HMPAO injection. For evaluation of differences between the images obtained at various time points after injection, two different methods were used. The z-map method was used to subtract images from each other prior to visual inspection. In addition, principal component analysis was used as a quantitative analysis of the similarity of the images.
RESULTS: Visual inspection of the subtracted images (30 or 60 versus 90 min) revealed that there was no spatial bias. Quantitatively, the average proportion of the total variance explained by the first principal component was 99.5% (range 98.9-99.6) for the healthy subjects and 99.4% (range 98.5-99.8) for the patients.
CONCLUSION: The time delay from injection of (99m)Tc-HMPAO to the start of the SPECT data acquisition can be reduced from 90 to 30 min without any significant impact on the quality of the acquired image.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18542960     DOI: 10.1007/s00259-008-0836-8

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  17 in total

1.  Rapid automated algorithm for aligning and reslicing PET images.

Authors:  R P Woods; S R Cherry; J C Mazziotta
Journal:  J Comput Assist Tomogr       Date:  1992 Jul-Aug       Impact factor: 1.826

2.  Subtraction SPECT co-registered to MRI improves postictal SPECT localization of seizure foci.

Authors:  T J O'Brien; E L So; B P Mullan; M F Hauser; B H Brinkmann; C R Jack; G D Cascino; F B Meyer; F W Sharbrough
Journal:  Neurology       Date:  1999-01-01       Impact factor: 9.910

3.  How to estimate global activity independent of changes in local activity.

Authors:  J L Andersson
Journal:  Neuroimage       Date:  1997-11       Impact factor: 6.556

4.  Procedure guideline for brain perfusion SPECT using technetium-99m radiopharmaceuticals. Society of Nuclear Medicine.

Authors:  J E Juni; A D Waxman; M D Devous; R S Tikofsky; M Ichise; R L Van Heertum; B L Holman; R F Carretta; C C Chen
Journal:  J Nucl Med       Date:  1998-05       Impact factor: 10.057

5.  Hypofixation and hyperfixation of 99mTc-hexamethyl propyleneamine oxime in subacute cerebral infarction.

Authors:  K Ogasawara; A Ogawa; K Koshu; H Konno; M Suzuki; T Yoshimoto
Journal:  J Nucl Med       Date:  2000-05       Impact factor: 10.057

6.  The retention of [99mTc]-d,l-HM-PAO in the human brain after intracarotid bolus injection: a kinetic analysis.

Authors:  N A Lassen; A R Andersen; L Friberg; O B Paulson
Journal:  J Cereb Blood Flow Metab       Date:  1988-12       Impact factor: 6.200

7.  Subtraction ictal SPET co-registered to MRI in partial epilepsy: description and technical validation of the method with phantom and patient studies.

Authors:  T J O'Brien; M K O'Connor; B P Mullan; B H Brinkmann; D Hanson; C R Jack; E L So
Journal:  Nucl Med Commun       Date:  1998-01       Impact factor: 1.690

8.  Quantitative measurements of cerebral blood flow using SPECT and [99mTc]-d,l-HM-PAO compared to xenon-133.

Authors:  A R Andersen; H H Friberg; J F Schmidt; S G Hasselbalch
Journal:  J Cereb Blood Flow Metab       Date:  1988-12       Impact factor: 6.200

9.  Cerebral infarction within six hours of onset: prediction of completed infarction with technetium-99m-HMPAO SPECT.

Authors:  E Shimosegawa; J Hatazawa; A Inugami; H Fujita; T Ogawa; Y Aizawa; I Kanno; T Okudera; K Uemura
Journal:  J Nucl Med       Date:  1994-07       Impact factor: 10.057

10.  Technetium-99m d,l-HM-PAO: a new radiopharmaceutical for SPECT imaging of regional cerebral blood perfusion.

Authors:  R D Neirinckx; L R Canning; I M Piper; D P Nowotnik; R D Pickett; R A Holmes; W A Volkert; A M Forster; P S Weisner; J A Marriott
Journal:  J Nucl Med       Date:  1987-02       Impact factor: 10.057

View more
  2 in total

1.  EANM procedure guideline for brain perfusion SPECT using 99mTc-labelled radiopharmaceuticals, version 2.

Authors:  Ozlem L Kapucu; Flavio Nobili; Andrea Varrone; Jan Booij; Thierry Vander Borght; Kjell Någren; Jacques Darcourt; Klaus Tatsch; Koen J Van Laere
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-12       Impact factor: 9.236

2.  Combined compared to dissociated oral and intestinal sucrose stimuli induce different brain hedonic processes.

Authors:  Caroline Clouard; Marie-Christine Meunier-Salaün; Paul Meurice; Charles-Henri Malbert; David Val-Laillet
Journal:  Front Psychol       Date:  2014-08-07
  2 in total