Corbin E Goerlich1,2, Laura DiChiacchio1, Tianshu Zhang1, Avneesh K Singh1, Billeta Lewis1, Ivan Tatarov1, Alena Hershfeld1, Faith Sentz1, David Ayares3, Philip Corcoran4, Keith Horvath5, Muhammad M Mohiuddin6.
Abstract
Heterotopic cardiac transplantation in the intra-abdominal position in a large animal model has been essential in the progression of the field of cardiac transplantation. Our group has over 10 years of experience in cardiac xenotransplantation with pig to baboon models, the longest xenograft of which survived over 900 days, with rejection only after reducing immunosuppression. This article aims to clarify our approach to this model in order to allow others to share success in long-term survival. Here, we demonstrate the approach to implantation of a cardiac graft into the intra-abdominal position in a baboon recipient for the study of transplantation and briefly highlight our model's ability to provide insight into not only xenotransplantation but across disciplines. We include details that have provided us with consistent success in this model; performance of the anastomoses, de-airing of the graft, implantation of a long-term telemetry device for invasive graft monitoring, and ideal geometric positioning of the heart and telemetry device in the limited space of the recipient abdomen. We additionally detail surveillance techniques to assess long-term graft function.Entities:
Mesh:
Substances:
Year: 2020 PMID: 32612124 PMCID: PMC7329828 DOI: 10.1038/s41598-020-66430-x
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Additional information on critical materials for heterotopic cardiac transplantation: while these are suggestions based on materials we have used, there are likely other suitable alternatives.
| Heterotopic Cardiac Xenotransplantation-Important Materials | ||
|---|---|---|
| Name | Manufacterer | Reference # |
| 9 Fr Cardioplegia Aortic Root Cannula | Medtronic (USA) | 20012 |
| Bladder Irrigation Tubing for Cardioplegia | Baxter (USA) | 2C4041 |
| Extension IV Tubing Set | icumedical (USA) | 12656-28 |
| Plegisol | Hospira Inc. (USA) | 409796905 |
| Data Sciences International (DSI) Telemetry Device L21 | DSI (USA) | DSI L21 |
| 10 Fr Hickmann Tunneled Triple Lumen Catheter | BARD (USA) | 606560 |
Figure 1Intraabdominal placement of a cardiac xenograft with pressure telemetry monitor in the apex. IVC-inferior vena cava, Ao-Aorta, PA-pulmonary artery, EKG-electrocardiogram leads from telemetry device. Of note, whereas the telemetry device depicted here only has one pressure sensor and it is placed in the left ventricle at the apex, the pressure can be placed in the right atrium, pulmonary artery or aorta as well, depending on which hemodynamic parameters of interest are to be studied. Image Copyright: Tim Phelps JHU/AAMM, 2020.
Figure 2Backtable preparation of the heart for transplantation. Ao-ascending aorta, PA-pulmonary artery, Pvv-Pulmonary vein common channel, Cava-superior and inferior vena caval junction. Image Copyright: Tim Phelps JHU/AAMM, 2020.
Figure 3Aortic and Pulmonic Anastomosis to the Recipient. Abdomen. Image Copyright: Tim Phelps JHU/AAMM, 2020. Aortic and Pulmonic Anastomosis to the Recipient. Abdomen. Image Copyright: Tim Phelps JHU/AAMM, 2020.
Figure 4Left ventricular thrombus in porcine xenograft.
Figure 5Perfusion of Blood Through the Heterotopic Cardiac Graft: The graft is perfused via its coronary vessels during graft diastole and aortic valve cooptation, supplied from the recipient aorta. Perfused blood from the graft is then drained into the right atrium via the coronary sinus. Solid arrows denote recipient native blood flow. Dotted arrows represent graft blood flow in systole (outward from graft major vessels) and diastole (into graft atria/ventricles).