Literature DB >> 32611455

Effect of newborn screening for critical CHD on healthcare utilisation.

Rie Sakai-Bizmark1,2, Hiraku Kumamaru3, Eliza J Webber1, Dennys Estevez1, Laurie A Mena1, Emily H Marr1, Ruey-Kang R Chang1,2.   

Abstract

OBJECTIVE: To evaluate the impact of state-mandated policies for pulse oximetry screening on healthcare utilisation, with a focus on use of echocardiograms. DATA SOURCES/STUDY
SETTING: Healthcare Cost and Utilisation Project, Statewide Inpatient Databases from 2008 to 2014 from six states.
METHODS: We defined pre- and post-mandate cohorts based on dates when pulse oximetry became mandated in each state. Linear segmented regression models for interrupted time series assessed associations between implementation of the screening and changes in rate of newborns with Critical CHD-negative echocardiogram results. We also evaluated the changes in rate of newborns who underwent echocardiogram but were not diagnosed with any health issues that could cause hypoxemia.
RESULTS: We identified 5967 critical CHD-negative echocardiograms (2847 and 3120 in the pre- and post-mandate periods, respectively). Our models detected a statistically significant increasing trend in rate of critical CHD-negative echocardiograms in the pre-mandate period (Incidence Rate Ratio: 1.08, p = 0.02), but did not detect any statistical differences in changes between pre- and post-mandate periods (Incidence Rate Ratio: 0.93, p = 0.14). Among non-Whites, an increasing trend of Critical CHD-negative echocardiogram during the pre-mandate period was detected (Incidence Rate Ratio 1.12, p < 0.01) and was attenuated during the post-mandate period (Incidence Rate Ratio 0.89, p = 0.02). Similar results were observed in the sensitivity analyses among both Whites and non-Whites.
CONCLUSIONS: Results suggest that mandatory state screening policies are associated with reductions in false-positive screening rates for hypoxemic conditions, with reductions primarily attributed to trends among non-Whites.

Entities:  

Keywords:  CHD; Critical CHD; hypoxemia; mandated policy; newborn

Mesh:

Year:  2020        PMID: 32611455      PMCID: PMC8096776          DOI: 10.1017/S1047951120001742

Source DB:  PubMed          Journal:  Cardiol Young        ISSN: 1047-9511            Impact factor:   1.093


  32 in total

1.  Pulse oximetry as a screening test for congenital heart defects in newborn infants: a cost-effectiveness analysis.

Authors:  T E Roberts; P M Barton; P E Auguste; L J Middleton; A T Furmston; A K Ewer
Journal:  Arch Dis Child       Date:  2012-01-13       Impact factor: 3.791

2.  Hospitalizations, costs, and mortality among infants with critical congenital heart disease: how important is timely detection?

Authors:  Cora Peterson; April Dawson; Scott D Grosse; Tiffany Riehle-Colarusso; Richard S Olney; Jean Paul Tanner; Russell S Kirby; Jane A Correia; Sharon M Watkins; Cynthia H Cassell
Journal:  Birth Defects Res A Clin Mol Teratol       Date:  2013-09-02

3.  Racial/Ethnic disparities in risk of early childhood mortality among children with congenital heart defects.

Authors:  Wendy N Nembhard; Jason L Salemi; Mary K Ethen; David E Fixler; Angela Dimaggio; Mark A Canfield
Journal:  Pediatrics       Date:  2011-04-18       Impact factor: 7.124

4.  Accuracy of pulse oximetry in pigmented patients.

Authors:  P A Bothma; G M Joynt; J Lipman; H Hon; B Mathala; J Scribante; J Kromberg
Journal:  S Afr Med J       Date:  1996-05

Review 5.  The incidence of congenital heart disease.

Authors:  Julien I E Hoffman; Samuel Kaplan
Journal:  J Am Coll Cardiol       Date:  2002-06-19       Impact factor: 24.094

6.  Dark skin decreases the accuracy of pulse oximeters at low oxygen saturation: the effects of oximeter probe type and gender.

Authors:  John R Feiner; John W Severinghaus; Philip E Bickler
Journal:  Anesth Analg       Date:  2007-12       Impact factor: 5.108

7.  False-Positive Newborn Screening for Cystic Fibrosis and Health Care Use.

Authors:  Robin Z Hayeems; Fiona A Miller; Marian Vermeulen; Beth K Potter; Pranesh Chakraborty; Christine Davies; June C Carroll; Felix Ratjen; Astrid Guttmann
Journal:  Pediatrics       Date:  2017-10-12       Impact factor: 7.124

8.  Impact of pulse oximetry screening on the detection of duct dependent congenital heart disease: a Swedish prospective screening study in 39,821 newborns.

Authors:  Anne de-Wahl Granelli; Margareta Wennergren; Kenneth Sandberg; Mats Mellander; Carina Bejlum; Leif Inganäs; Monica Eriksson; Niklas Segerdahl; Annelie Agren; Britt-Marie Ekman-Joelsson; Jan Sunnegårdh; Mario Verdicchio; Ingegerd Ostman-Smith
Journal:  BMJ       Date:  2009-01-08

9.  Assessment of current practices and feasibility of routine screening for critical congenital heart defects - Georgia, 2012.

Authors: 
Journal:  MMWR Morb Mortal Wkly Rep       Date:  2013-04-19       Impact factor: 17.586

10.  The health system impact of false positive newborn screening results for medium-chain acyl-CoA dehydrogenase deficiency: a cohort study.

Authors:  Maria D Karaceper; Pranesh Chakraborty; Doug Coyle; Kumanan Wilson; Jonathan B Kronick; Steven Hawken; Christine Davies; Marni Brownell; Linda Dodds; Annette Feigenbaum; Deshayne B Fell; Scott D Grosse; Astrid Guttmann; Anne-Marie Laberge; Aizeddin Mhanni; Fiona A Miller; John J Mitchell; Meranda Nakhla; Chitra Prasad; Cheryl Rockman-Greenberg; Rebecca Sparkes; Brenda J Wilson; Beth K Potter
Journal:  Orphanet J Rare Dis       Date:  2016-02-03       Impact factor: 4.123

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.