Literature DB >> 32595789

Mid-Term Results of Frozen Elephant Trunk Technique for Chronic Aortic Dissection.

Yoshitaka Yamane1, Keijiro Katayama1, Tomokuni Furukawa2, Haruna Shimizu1, Takanobu Okazaki1, Taiichi Takasaki1, Tatsuya Kurosaki1, Shinya Takahashi1.   

Abstract

Objective: In this study, we report our experience using the frozen elephant trunk (FET) technique for chronic aortic dissection.
Methods: Between January 2011 and December 2017, 15 patients underwent total arch replacement (TAR) with the FET technique for chronic aortic dissection (CAD).
Results: Hospital mortality was 6.7% (n=1). No patients experienced spinal cord injury. Distal stent-induced new entry (dSINE) occurred in the early postoperative period in one patient. There were four unplanned additional operations to manage dSINE. Five patients suffered from dSINE, and aortoesophageal fistula developed in three of them. Short insertion length of the FET and large angle between the distal edge of the FET and the descending aorta were significantly more common in the dSINE group than in the non-dSINE group. The cumulative survival rates at 1, 3, and 5 years were 93.3%, 93.3%, and 66.4%, respectively. The cumulative aortic event-free rates at 1, 2, and 3 years were 85.7%, 77.1%, and 52.9%, respectively.
Conclusion: The FET technique for CAD provided good early results. Short insertion length of the FET, however, can induce dSINE, which requires an additional operation at mid-term. Thus, surgical indication of the FET technique for CAD must be discussed.
Copyright © 2020 Annals of Vascular Diseases.

Entities:  

Keywords:  aortic dissection; chronic aortic dissection; frozen elephant trunk

Year:  2020        PMID: 32595789      PMCID: PMC7315230          DOI: 10.3400/avd.oa.19-00131

Source DB:  PubMed          Journal:  Ann Vasc Dis        ISSN: 1881-641X


  18 in total

1.  Frozen elephant trunk technique for extensive chronic thoracic aortic dissection: is it the final answer?

Authors:  Nicholas T Kouchoukos
Journal:  Ann Thorac Surg       Date:  2011-10-31       Impact factor: 4.330

2.  Re: Impact of clinical factors and surgical techniques on early outcome of patients treated with frozen elephant trunk technique by using EVITA open stent-graft: results of a multicentre study.

Authors:  Malakh Shrestha
Journal:  Eur J Cardiothorac Surg       Date:  2015-09-18       Impact factor: 4.191

3.  Comparisons of aortic remodelling and outcomes after endovascular repair of acute and chronic complicated Type B aortic dissections.

Authors:  Heng-Wen Chou; Chih-Yang Chan; Chin-Hao Chang; Ching-Feng Lin; Yih-Sharng Chen; Shoei-Shen Wang; I-Hui Wu
Journal:  Interact Cardiovasc Thorac Surg       Date:  2018-11-01

4.  Short- and midterm results after hybrid treatment of chronic aortic dissection with the frozen elephant trunk technique.

Authors:  Marco Di Eusanio; Alessandro Armaro; Luca Di Marco; Davide Pacini; Carlo Savini; Sofia Martin Suarez; Emanuele Pilato; Roberto Di Bartolomeo
Journal:  Eur J Cardiothorac Surg       Date:  2011-03-05       Impact factor: 4.191

5.  Early- and mid-term aortic remodelling after the frozen elephant trunk technique for retrograde type A acute aortic dissection using the new Japanese J Graft open stent graft.

Authors:  Yoshitaka Yamane; Naomichi Uchida; Shingo Mochizuki; Tomokuni Furukawa; Kazunori Yamada
Journal:  Interact Cardiovasc Thorac Surg       Date:  2017-11-01

6.  Factors Affecting Optimal Aortic Remodeling After Thoracic Endovascular Aortic Repair of Type B (IIIb) Aortic Dissection.

Authors:  I-Ming Chen; Po-Lin Chen; Chun-Yang Huang; Shih-Hsien Weng; Wei-Yuan Chen; Chun-Che Shih
Journal:  Cardiovasc Intervent Radiol       Date:  2017-01-23       Impact factor: 2.740

7.  The Impact of Distal Stent Graft-Induced New Entry on Aortic Remodeling of Chronic Type B Dissection.

Authors:  Chun-Yang Huang; Hung-Lung Hsu; Po-Lin Chen; I-Ming Chen; Chiao-Po Hsu; Chun-Che Shih
Journal:  Ann Thorac Surg       Date:  2017-12-02       Impact factor: 4.330

8.  Risk factors for distal stent graft-induced new entry following endovascular repair of type B aortic dissection.

Authors:  Qing Li; Long-Fei Wang; Wei-Guo Ma; Shang-Dong Xu; Jun Zheng; Xiao-Yan Xing; Lian-Jun Huang; Li-Zhong Sun
Journal:  J Thorac Dis       Date:  2015-11       Impact factor: 2.895

9.  Stent graft-induced new entry after endovascular repair for Stanford type B aortic dissection.

Authors:  Zhihui Dong; Weiguo Fu; Yuqi Wang; Chunsheng Wang; Zhiping Yan; Daqiao Guo; Xin Xu; Bin Chen
Journal:  J Vasc Surg       Date:  2010-08-25       Impact factor: 4.268

10.  A new device as an open stent graft for extended aortic repair: a multicentre early experience in Japan.

Authors:  Naomichi Uchida; Akira Katayama; Shinichi Higashiue; Motomi Shiono; Mitsumasa Hata; Kazutomo Minami; Kazuo Yamanaka; Shinji Miyamoto; Yoshiki Sawa; Toru Kuratani; Masaaki Kato
Journal:  Eur J Cardiothorac Surg       Date:  2015-09-18       Impact factor: 4.191

View more
  1 in total

Review 1.  Incidence of Distal Stent Graft Induced New Entry vs. Aortic Remodeling Associated With Frozen Elephant Trunk.

Authors:  Matti Jubouri; Fatima Kayali; Priyanshu Saha; Daniyal M Ansari; Yousef Rezaei; Sven Z C P Tan; Mostafa Mousavizadeh; Saeid Hosseini; Idhrees Mohammed; Mohamad Bashir
Journal:  Front Cardiovasc Med       Date:  2022-03-10
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.