Early- and mid-term aortic remodelling after the frozen elephant trunk technique for retrograde type A acute aortic dissection using the new Japanese J Graft open stent graft.

Yoshitaka Yamane1, Naomichi Uchida1, Shingo Mochizuki1, Tomokuni Furukawa1, Kazunori Yamada1.   

Abstract

OBJECTIVES: We previously performed the frozen elephant trunk (FET) technique for acute type A aortic dissection to try to improve the long-term prognosis. In this study, we report the mid-term results of the FET technique for treating retrograde type A acute aortic dissection using a new device, the J Graft open stent graft (JOSG).
METHODS: Between January 2008 and December 2015, 24 patients (mean age: 59.3 ± 13.9 years) underwent total arch replacement with the FET technique using the JOSG for retrograde type A acute aortic dissection. All patients had at least 1 year of follow-up imaging.
RESULTS: The average outer diameter of the JOSG was 28 ± 2.8 mm (range: 25-35 mm). The average position of the distal edge of the JOSG was Th 6.6 ± 1.1. The cumulative survival rate at 1 year was 91.6%. Postoperative computed tomography 1 year after surgery showed that complete thrombosis was present in all patients at the level of the distal edge of the stent graft and the aortic valve. At the diaphragmatic level, complete thrombosis was seen in 14 (70%) patients, the false lumen was patent in most patients (90%) at the superior mesenteric artery level.
CONCLUSIONS: The use of the FET technique with the JOSG for retrograde type A acute aortic dissection provides good outcomes. With the proper use of the JOSG, it is possible to expand the true lumen and eliminate antegrade false-lumen flow, resulting in good aortic remodelling. Furthermore, there should be obliteration of the false lumen from the stent graft to the aortic valve, and this might reduce long-term complications.
© The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Aortic arch; Aortic dissection; Surgery

Mesh:

Year:  2017        PMID: 28605548     DOI: 10.1093/icvts/ivx144

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  12 in total

1.  Risk factors for spinal cord injury in patients undergoing frozen elephant trunk technique for acute aortic dissection.

Authors:  Daijiro Hori; Sho Kusadokoro; Koichi Adachi; Naoyuki Kimura; Koichi Yuri; Harunobu Matsumoto; Atsushi Yamaguchi
Journal:  Gen Thorac Cardiovasc Surg       Date:  2019-08-29

2.  Aortic remodeling with frozen elephant trunk technique for Stanford type A aortic dissection using Japanese J-graft open stent graft.

Authors:  Masato Tochii; Yoshiyuki Takami; Hiroshi Ishikawa; Michiko Ishida; Yoshiro Higuchi; Yusuke Sakurai; Kentaro Amano; Yasushi Takagi
Journal:  Heart Vessels       Date:  2018-09-06       Impact factor: 2.037

3.  Repeat surgical intervention after aortic repair for acute Stanford type A dissection.

Authors:  Tadashi Kitamura; Shinzo Torii; Kensuke Kobayashi; Yuki Tanaka; Akihiro Sasahara; Haruna Araki; Yuki Ohtomo; Rihito Horikoshi; Kagami Miyaji
Journal:  Gen Thorac Cardiovasc Surg       Date:  2018-08-04

4.  Long-term outcomes of the frozen elephant trunk procedure: a systematic review.

Authors:  David H Tian; Hakeem Ha; Yashutosh Joshi; Tristan D Yan
Journal:  Ann Cardiothorac Surg       Date:  2020-05

5.  Proximalized Total Arch Replacement Can Be Safely Performed by Trainee.

Authors:  Sentaro Nakanishi; Naohiro Wakabayashi; Hayato Ise; Hiroto Kitahara; Aina Hirofuji; Natsuya Ishikawa; Hiroyuki Kamiya
Journal:  Thorac Cardiovasc Surg       Date:  2020-07-07       Impact factor: 1.827

6.  Equations for Estimating the Predissected Diameter of the Descending Aorta From Computed Tomographic Images at the Onset of Aortic Dissection.

Authors:  Takashi Yamauchi; Takafumi Masai; Hiroshi Takano; Yukitoshi Shirakawa; Koichi Toda; Yoshiki Sawa
Journal:  J Am Heart Assoc       Date:  2018-06-26       Impact factor: 5.501

7.  Hybrid Repair for Ruptured Thoracic Aortic Aneurysm: Frozen Elephant Trunk Technique with Thoracic Endovascular Aortic Repair.

Authors:  Yoshitaka Yamane; Toshifumi Hiraoka; Shingo Mochizuki; Tomokuni Furukawa; Kazunori Yamada
Journal:  Ann Vasc Dis       Date:  2018-06-25

8.  Mid-Term Results of Frozen Elephant Trunk Technique for Chronic Aortic Dissection.

Authors:  Yoshitaka Yamane; Keijiro Katayama; Tomokuni Furukawa; Haruna Shimizu; Takanobu Okazaki; Taiichi Takasaki; Tatsuya Kurosaki; Shinya Takahashi
Journal:  Ann Vasc Dis       Date:  2020-06-25

9.  Redo Descending Aortic Replacement via Direct Anastomosis to J Graft Open Stent Graft.

Authors:  Sho Kusadokoro; Daijiro Hori; Ryo Itagaki; Koichi Adachi; Atsushi Yamaguchi
Journal:  Ann Vasc Dis       Date:  2019-09-25

10.  Aorto-Esophageal Fistula Caused by Distal Stent Graft-Induced New Entry after Frozen Elephant Trunk Technique for Chronic Aortic Dissection.

Authors:  Yoshitaka Yamane; Keijiro Katayama; Shinya Takahashi; Tatsuya Kurosaki; Taijiro Sueda
Journal:  Ann Vasc Dis       Date:  2019-09-25
View more