Literature DB >> 26716029

Risk factors for distal stent graft-induced new entry following endovascular repair of type B aortic dissection.

Qing Li1, Long-Fei Wang1, Wei-Guo Ma1, Shang-Dong Xu1, Jun Zheng1, Xiao-Yan Xing1, Lian-Jun Huang1, Li-Zhong Sun1.   

Abstract

BACKGROUND: Distal stent graft-induced new entry (DSINE) has been increasingly observed following thoracic endovascular aortic repair (TEVAR) for type B aortic dissection (TBAD). We seek to identify the risk factors for DSINE following TEVAR in patients with TBAD.
METHODS: Between January 2009 and January 2013, we performed TEVAR for 579 patients with TBAD. The clinical data were retrospectively analyzed with univariate and multivariate analyses to identify the risk factors for DSINE.
RESULTS: Two patients (0.3%) died after the initial TEVAR. Morbidity included spinal cord injury in 2 (0.3%), stroke in 3 (0.5%) and endoleak in 12 (2.1%) patients. Clinical and radiological follow-up was complete in 100% (577/577) averaging 47±16 months. Late death occurred in 6 patients. DSINE occurred in 39 patients (6.7%) at mean 22±17 months after the initial TEVAR, which was managed with re-TEVAR in 25 and medically in 14. At 33±18 months after DSINE, 11 of patients managed medically (11/14) and all patients managed with re-TEVAR (25/25) survived (P=0.048). Freedom from DSINE was 92.7% at 5 years (95% CI: 90.0-94.7%). Using tapered stent grafts with a proximal end 4-8 mm larger than the distal end, TEVAR performed in the acute phase (≤14 days from onset) was associated with a significantly lower incidence of DSINE than TEVAR performed in the chronic phase (4.3%, 7/185 vs. 13.9%, 15/108; P=0.003). Risk factors for DSINE were stent grafts less than 145 mm in length [odds ratio (OR) 2.268; 95% CI: 1.121-4.587; P=0.023] and TEVAR performed in the chronic phase (OR 1.935; 95% CI: 1.004-3.731; P=0.049).
CONCLUSIONS: Our results show that TEVAR performed during the acute phase and using stent grafts longer than 145 mm could decrease the incidence of DSINE in patients with TBAD. Tapered stent grafts with a proximal end 4-8 mm larger than the distal end may be helpful in preventing DSINE after TEVAR performed in the acute phase than TEVAR performed in the chronic phase, due to the difference in mobility of the dissected flap. Expedite repeat TEVAR is recommended to improve the clinical prognosis for patients with DSINE.

Entities:  

Keywords:  Aortic dissection; endovascular; new entry; stent graft; type B

Year:  2015        PMID: 26716029      PMCID: PMC4669288          DOI: 10.3978/j.issn.2072-1439.2015.11.27

Source DB:  PubMed          Journal:  J Thorac Dis        ISSN: 2072-1439            Impact factor:   2.895


  22 in total

1.  Endovascular stent-graft placement for the treatment of acute aortic dissection.

Authors:  M D Dake; N Kato; R S Mitchell; C P Semba; M K Razavi; T Shimono; T Hirano; K Takeda; I Yada; D C Miller
Journal:  N Engl J Med       Date:  1999-05-20       Impact factor: 91.245

2.  Early and medium-term results of stent-graft treatment of DeBakey type III aortic dissection.

Authors:  I Kiyotaka; S Shinichi; U Keiji
Journal:  J Cardiovasc Surg (Torino)       Date:  2006-12       Impact factor: 1.888

3.  A study of aortic dimension in type B aortic dissection.

Authors:  Shang Dong Xu; Fang Jiong Huang; Jia Hui Du; Yu Li; Zhan Ming Fan; Jin Fei Yang; Xiao Ying Yu; Zhao Guang Zhang
Journal:  Interact Cardiovasc Thorac Surg       Date:  2008-01-10

4.  Restrictive bare stent for prevention of stent graft-induced distal redissection after thoracic endovascular aortic repair for type B aortic dissection.

Authors:  Jiaxuan Feng; Qingsheng Lu; Zhiqing Zhao; Junmin Bao; Xiang Feng; Lefeng Qu; Jian Zhou; Zaiping Jing
Journal:  J Vasc Surg       Date:  2013-02       Impact factor: 4.268

5.  Current management and outcome of chronic type B aortic dissection: results with open and endovascular repair since the advent of thoracic endografting.

Authors:  Nicholas D Andersen; Jeffrey E Keenan; Asvin M Ganapathi; Jeffrey G Gaca; Richard L McCann; G Chad Hughes
Journal:  Ann Cardiothorac Surg       Date:  2014-05

6.  Modified Petticoat Technique with Pre-placement of a Distal Bare Stent Improves Early Aortic Remodeling after Complicated Acute Stanford Type B Aortic Dissection.

Authors:  H He; K Yao; W P Nie; Z Wang; Q Liang; C Shu; A Dardik
Journal:  Eur J Vasc Endovasc Surg       Date:  2015-06-19       Impact factor: 7.069

7.  Thoracic aortic aneurysm expansion due to late distal stent graft-induced new entry.

Authors:  Rolf Alexander Jánosi; Konstantinos Tsagakis; Markus Bettin; Philipp Kahlert; Michael Horacek; Fadi Al-Rashid; Thomas Schlosser; Heinz Jakob; Holger Eggebrecht; Raimund Erbel
Journal:  Catheter Cardiovasc Interv       Date:  2014-08-05       Impact factor: 2.692

8.  Nonsurgical reconstruction of thoracic aortic dissection by stent-graft placement.

Authors:  C A Nienaber; R Fattori; G Lund; C Dieckmann; W Wolf; Y von Kodolitsch; V Nicolas; A Pierangeli
Journal:  N Engl J Med       Date:  1999-05-20       Impact factor: 91.245

9.  Aortic remodeling after endovascular repair with stainless steel-based stent graft in acute and chronic type B aortic dissection.

Authors:  Chih-Pei Ou Yang; Chiao-Po Hsu; Wei-Yuan Chen; I-Ming Chen; Chi-Feng Weng; Chun-Ku Chen; Chun-Che Shih
Journal:  J Vasc Surg       Date:  2012-03-28       Impact factor: 4.268

10.  Stent graft-induced new entry after endovascular repair for Stanford type B aortic dissection.

Authors:  Zhihui Dong; Weiguo Fu; Yuqi Wang; Chunsheng Wang; Zhiping Yan; Daqiao Guo; Xin Xu; Bin Chen
Journal:  J Vasc Surg       Date:  2010-08-25       Impact factor: 4.268

View more
  11 in total

1.  Is the frozen elephant trunk technique justified for chronic type A aortic dissection in Marfan syndrome?

Authors:  Yu Chen; Wei-Guo Ma; Jian-Rong Li; Jun Zheng; Yong-Min Liu; Jun-Ming Zhu; Li-Zhong Sun
Journal:  Ann Cardiothorac Surg       Date:  2020-05

2.  Recent evolution in use and effectiveness in mainland China of thoracic endovascular aortic repair of type B aortic dissection.

Authors:  Jiang Xiong; Chen Chen; Zhongyin Wu; Duanduan Chen; Wei Guo
Journal:  Sci Rep       Date:  2017-12-11       Impact factor: 4.379

3.  Mid-Term Results of Frozen Elephant Trunk Technique for Chronic Aortic Dissection.

Authors:  Yoshitaka Yamane; Keijiro Katayama; Tomokuni Furukawa; Haruna Shimizu; Takanobu Okazaki; Taiichi Takasaki; Tatsuya Kurosaki; Shinya Takahashi
Journal:  Ann Vasc Dis       Date:  2020-06-25

4.  Aortic remodeling in Type B aortic dissection after thoracic endovascular aortic repair with an aortic extender cuff implantation.

Authors:  Honggang Zhang; Tong Qiao
Journal:  Clin Interv Aging       Date:  2018-11-15       Impact factor: 4.458

5.  Aorto-Esophageal Fistula Caused by Distal Stent Graft-Induced New Entry after Frozen Elephant Trunk Technique for Chronic Aortic Dissection.

Authors:  Yoshitaka Yamane; Keijiro Katayama; Shinya Takahashi; Tatsuya Kurosaki; Taijiro Sueda
Journal:  Ann Vasc Dis       Date:  2019-09-25

6.  Rapidly Progressed Distal Arch Aneurysm with Distal Open Stent Graft-Induced New Entry Caused by "Spring-Back" Force.

Authors:  Masami Takagaki; Hirofumi Midorikawa; Hiroki Yamaguchi; Hiromasa Nakamura; Tasuku Kadowaki; Yousuke Ueno; Takaki Uchida; Tomoyuki Aoki
Journal:  Ann Vasc Dis       Date:  2020-09-25

7.  Influence of measurement and sizing techniques in thoracic endovascular aortic repair on outcome in acute complicated type B aortic dissections.

Authors:  Miriam Rychla; Philip Dueppers; Lorenz Meuli; Zoran Rancic; Anna-Leonie Menges; Reinhard Kopp; Alexander Zimmermann; Benedikt Reutersberg
Journal:  Interact Cardiovasc Thorac Surg       Date:  2022-03-31

8.  Endovascular repair of type B aortic dissection with the restrictive bare stent technique: morphologic changes, technique details, and outcomes.

Authors:  Binshan Zha; Geliang Xu; Huagang Zhu; Wentao Xie; Zhigong Zhang; Yongsheng Li; Peng Qiu
Journal:  Ther Clin Risk Manag       Date:  2018-10-12       Impact factor: 2.423

9.  Rapid false lumen dilation and pseudocoarctation due to inadvertent preferential false lumen perfusion using the frozen elephant trunk technique in a chronic residual aortic dissection.

Authors:  Jelle Fleerakkers; Uday Sonker; Robin H Heijmen
Journal:  J Vasc Surg Cases Innov Tech       Date:  2020-02-20

10.  Re-TEVAR in treatment of stent graft-induced new entry between two non-overlapping stent-grafts: a case report.

Authors:  Yiwei He; Shoujun Tang; Yongheng Zhang; Jianping Liu; Haining Zhou
Journal:  J Cardiothorac Surg       Date:  2020-10-15       Impact factor: 1.637

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.