Literature DB >> 32557880

A semi-LASER, single-voxel spectroscopic sequence with a minimal echo time of 20.1 ms in the human brain at 3 T.

Karl Landheer1, Martin Gajdošík1, Christoph Juchem1,2.   

Abstract

An optimized semi-LASER sequence that is capable of acquiring artefact-free data with an echo time (TE) of 20.1 ms on a standard clinical 3 T MR system was developed. Simulations were performed to determine the optimal TEs that minimize the expected Cramér-Rao lower bound (CRLB) as proxy for quantification accuracy of metabolites. Optimized RF pulses, crusher gradients and phase cycling were used to achieve the shortest TE in a semi-LASER sequence to date on a clinical system. Synthetic spectra were simulated using the density matrix formalism for TEs spanning from 20.1 to 220.1 ms. These simulations were used to calculate the expected CRLB for each of the 18 metabolites typically considered in 1 H MRS. High quality spectra were obtained in six healthy volunteers in the prefrontal cortex, which is known for spurious echoes due to its proximity to the paranasal sinuses, and in the parietal-occipital cortex. Spectral transients were sufficient in quality to enable phase and frequency alignment prior to summation over all repetitions. Automated high-quality water suppression was obtained for all voxels without manual adjustment. The shortest TE minimized the CRLB for all brain metabolites except glycine due to its overlap with myo-inositol at this TE. It is also demonstrated that the CRLBs increase rapidly with TE for certain coupled metabolites.
© 2020 John Wiley & Sons, Ltd.

Entities:  

Keywords:  VAPOR; magnetic resonance spectroscopy; semi-LASER; short-TE spectroscopy; single-voxel spectroscopy

Year:  2020        PMID: 32557880     DOI: 10.1002/nbm.4324

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  3 in total

1.  Comparison of linear combination modeling strategies for edited magnetic resonance spectroscopy at 3 T.

Authors:  Helge J Zöllner; Sofie Tapper; Steve C N Hui; Peter B Barker; Richard A E Edden; Georg Oeltzschner
Journal:  NMR Biomed       Date:  2021-09-23       Impact factor: 4.044

2.  Effect of Ketamine on Human Neurochemistry in Posterior Cingulate Cortex: A Pilot Magnetic Resonance Spectroscopy Study at 3 Tesla.

Authors:  Petr Bednarik; Benjamin Spurny; Leo R Silberbauer; Alena Svatkova; Patricia A Handschuh; Birgit Reiter; Melisande E Konadu; Thomas Stimpfl; Marie Spies; Wolfgang Bogner; Rupert Lanzenberger
Journal:  Front Neurosci       Date:  2021-03-24       Impact factor: 4.677

3.  INSPECTOR: free software for magnetic resonance spectroscopy data inspection, processing, simulation and analysis.

Authors:  Martin Gajdošík; Karl Landheer; Kelley M Swanberg; Christoph Juchem
Journal:  Sci Rep       Date:  2021-01-22       Impact factor: 4.379