Assessment of set-up errors in the radiotherapy of patients with head and neck cancer: standard vs. individual head support.

Sabina Androjna1, Valerija Zager Marcius1,2, Primoz Peterlin1, Primoz Strojan1,3.   

Abstract

Background The aim of the study was to (a) compare the accuracy of two different immobilization strategies for patients with head and neck tumors, and (b) compare the set-up errors on treatment units with different portal imaging systems. Patients and methods Variations in the position of the isocenter (IC) relative to the reference point determined on the computed tomography simulator were measured in a vertical (anterior-posterior), longitudinal (superior-inferior), and lateral (medial-lateral) direction in 120 head and neck cancer patients irradiated with curative intent. Depending on the treatment unit (unit A - 2D/2D image previews; unit B- 2D image previews) and the time of irradiation, patients were divided into 6 groups of 20 patients. In patients irradiated in 2014, standard head supports were used (groups 1 and 2), whereas in those treated in 2015 and 2017 (groups 3-6) individual head supports were employed. The clinical-to-planning target volume safety margin was calculated according to the formula proposed by Van Herk. Results In total, 2,454 portal images and 3,681 set-up errors were analysed. Implementation of individual head supports in 2015 resulted in a statistically significant reduction in the average inter-fraction displacement in the vertical direction and in decreased number of IC displacements in the vertical and longitudinal direction (applies to both treatment units). The largest reduction of the safety margin was calculated in the longitudinal direction and the safety margins were larger for unit B than for unit A. Conclusions The use of individual head supports and a more advanced imaging system were found to increase set-up precision.

Entities:  

Keywords:  head and neck radiotherapy; head support; immobilization; set-up errors

Year:  2020        PMID: 32549179      PMCID: PMC7409610          DOI: 10.2478/raon-2020-0036

Source DB:  PubMed          Journal:  Radiol Oncol        ISSN: 1318-2099            Impact factor:   2.991


  7 in total

Review 1.  Errors and margins in radiotherapy.

Authors:  Marcel van Herk
Journal:  Semin Radiat Oncol       Date:  2004-01       Impact factor: 5.934

2.  Assessment of a customised immobilisation system for head and neck IMRT using electronic portal imaging.

Authors:  Mandy Humphreys; M Teressa Guerrero Urbano; Cefas Mubata; Elizabeth Miles; Kevin J Harrington; Margaret Bidmead; Christopher M Nutting
Journal:  Radiother Oncol       Date:  2005-09-08       Impact factor: 6.280

3.  eNAL: an extension of the NAL setup correction protocol for effective use of weekly follow-up measurements.

Authors:  Hans C J de Boer; Ben J M Heijmen
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-04-01       Impact factor: 7.038

4.  G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences.

Authors:  Franz Faul; Edgar Erdfelder; Albert-Georg Lang; Axel Buchner
Journal:  Behav Res Methods       Date:  2007-05

5.  Improved immobilization using an individual head support in head and neck cancer patients.

Authors:  Antonetta C Houweling; Skadi van der Meer; Edwin van der Wal; Chris H J Terhaard; Cornelis P J Raaijmakers
Journal:  Radiother Oncol       Date:  2010-04-27       Impact factor: 6.280

6.  A simple and inexpensive method to routinely produce customized neck supports for patient immobilization during radiotherapy.

Authors:  B McKernan; S Bydder; M Ebert; D Waterhouse; D Joseph
Journal:  J Med Imaging Radiat Oncol       Date:  2008-12       Impact factor: 1.735

7.  Set-up improvement in head and neck radiotherapy using a 3D off-line EPID-based correction protocol and a customised head and neck support.

Authors:  Emile N J Th van Lin; Lisette van der Vight; Henk Huizenga; Johannes H A M Kaanders; Andries G Visser
Journal:  Radiother Oncol       Date:  2003-08       Impact factor: 6.280

  7 in total
  1 in total

1.  Accuracy of surface-guided patient setup for conventional radiotherapy of brain and nasopharynx cancer.

Authors:  Sang Kyu Lee; Sheng Huang; Lei Zhang; Ase M Ballangrud; Michalis Aristophanous; Laura I Cervino Arriba; Guang Li
Journal:  J Appl Clin Med Phys       Date:  2021-03-31       Impact factor: 2.102

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.